REVERSED-PHASE LIQUID-CHROMATOGRAPHY COUPLED ONLINE WITH CAPILLARY GAS-CHROMATOGRAPHY .2. USE OF A SOLVENT VAPOR EXIT TO INCREASE INTRODUCTION VOLUMES AND INTRODUCTION RATES INTO THE GAS-CHROMATOGRAPH

被引:25
|
作者
GOOSENS, EC [1 ]
DEJONG, D [1 ]
DEJONG, GJ [1 ]
BRINKMAN, UAT [1 ]
机构
[1] FREE UNIV AMSTERDAM,DEPT ANALYT CHEM,1081 HV AMSTERDAM,NETHERLANDS
关键词
CAPILLARY GC; REVERSED-PHASE LC; ONLINE COUPLING; SOLVENT VAPOR EXIT; PRESSURE-BALANCED CARRIER GAS SYSTEM;
D O I
10.1002/mcs.1220060303
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A large-volume introduction system for capillary gas chromatography (GC) is described which can be coupled on-line with reversed-phase liquid chromatography (LC) using 2 mm i.d. LC columns. An on-column interface with a special retention gap, coated with a very thin film (0.02 mum) of Carbowax was used. Insertion of a solvent vapor exit before the analytical gas chromatography column allowed the solvent evaporation rate for an azeotropic acetonitrile/water mixture (84:16, v/v) to increase from 20 to 175 muL min-1 at 91-degrees-C and 150 kPa inlet pressure. A volume of 200 muL of this mixture containing phenanthrene and the potential basic drug eltoprazine, could be injected into the retention gap at introduction rates of up to 200 muL min-1, under partially concurrent solvent evaporation conditions. Repeatability (CV = 2.4%) and linearity (at least 10-1000 ng mL-1) were satisfactory. The Carbowax-coated retention gap has a relatively large retention power for the polar solute. This means that the solvent can be completely evaporated through the vapor exit without loss of analyte. With apolar solutes, losses will occur if evaporation is unduly prolonged. In order to allow the use of a nitrogen-phosphorus detector, a special pressure-balanced carrier gas circuit was designed and tested for total solvent-free performance of the detector. With this set-up, 150 muL injections of eltoprazine in the acetonitrile/water azeotrope were made at an introduction rate of 200 muL min-1. No traces of acetonitrile were detected, while analyte detectability was 20-fold higher than with the FID. Finally, the practicability of reversed-phase LC-GC was demonstrated by on-line heart-cutting of the phenanthrene-containing fraction from a 2 mm i.d. LC column using acetonitrile/water (84:16, v/v) as eluent, and analyzing it by capillary GC-FID.
引用
收藏
页码:207 / 215
页数:9
相关论文
共 38 条
  • [1] REVERSED-PHASE LIQUID-CHROMATOGRAPHY COUPLED ONLINE WITH CAPILLARY GAS-CHROMATOGRAPHY .1. INTRODUCTION OF LARGE VOLUMES OF AQUEOUS MIXTURES THROUGH AN ON-COLUMN INTERFACE
    GOOSENS, EC
    DEJONG, D
    VANDENBERG, JHM
    DEJONG, GJ
    BRINKMAN, UAT
    JOURNAL OF CHROMATOGRAPHY, 1991, 552 (1-2): : 489 - 500
  • [2] COUPLED REVERSED-PHASE LIQUID-CHROMATOGRAPHY CAPILLARY GAS-CHROMATOGRAPHY FOR THE DETERMINATION OF ATRAZINE IN WATER
    GROB, K
    LI, ZW
    JOURNAL OF CHROMATOGRAPHY, 1989, 473 (02): : 423 - 430
  • [3] A TRAPPING COLUMN FOR THE COUPLING OF REVERSED-PHASE LIQUID-CHROMATOGRAPHY AND CAPILLARY GAS-CHROMATOGRAPHY
    VREULS, JJ
    GOUDRIAAN, VP
    BRINKMAN, UAT
    DEJONG, GJ
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1991, 14 (07): : 475 - 480
  • [4] USE OF AN OPEN-TUBULAR TRAPPING COLUMN AS PHASE-SWITCHING INTERFACE IN ONLINE COUPLED REVERSED-PHASE LIQUID-CHROMATOGRAPHY CAPILLARY GAS-CHROMATOGRAPHY
    MOL, HGJ
    STANIEWSKI, J
    JANSSEN, HG
    CRAMERS, CA
    GHIJSEN, RT
    BRINKMAN, UAT
    JOURNAL OF CHROMATOGRAPHY, 1993, 630 (1-2): : 201 - 212
  • [5] ONLINE REVERSED-PHASE LIQUID-CHROMATOGRAPHY CAPILLARY GAS-CHROMATOGRAPHY USING A PROGRAMMED-TEMPERATURE VAPORIZER AS INTERFACE
    SENORANS, FJ
    HERRAIZ, M
    TABERA, J
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1995, 18 (07): : 433 - 438
  • [6] USE OF A PROGRAMMED-TEMPERATURE INJECTOR FOR ONLINE REVERSED-PHASE LIQUID CHROMATOGRAPHY-CAPILLARY GAS-CHROMATOGRAPHY
    SENORANS, FJ
    REGLERO, G
    HERRAIZ, M
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1995, 33 (08) : 446 - 450
  • [7] DETERMINATION OF BOVINE BUTTERFAT TRIACYLGLYCEROLS BY REVERSED-PHASE LIQUID-CHROMATOGRAPHY AND GAS-CHROMATOGRAPHY
    MANIONGUI, C
    GRESTI, J
    BUGAUT, M
    GAUTHIER, S
    BEZARD, J
    JOURNAL OF CHROMATOGRAPHY, 1991, 543 (01): : 81 - 103
  • [8] REVERSED-PHASE LIQUID-CHROMATOGRAPHY COUPLED ONLINE WITH CAPILLARY GAS-CHROMATOGRAPHY - USE OF AN ANION-EXCHANGE MEMBRANE TO REMOVE AN ION-PAIR REAGENT FROM THE ELUENT
    GOOSENS, EC
    BEERTHUIZEN, IM
    DEJONG, D
    DEJONG, GJ
    BRINKMAN, UAT
    CHROMATOGRAPHIA, 1995, 40 (5-6) : 267 - 271
  • [9] DETERMINATION OF CYCLOPROPENOIC FATTY-ACIDS BY REVERSED-PHASE LIQUID-CHROMATOGRAPHY AND GAS-CHROMATOGRAPHY
    GAYDOU, EM
    BIANCHINI, JP
    RALAIMANARIVO, A
    ANALYTICAL CHEMISTRY, 1983, 55 (14) : 2313 - 2317
  • [10] Stereodifferentiation of chiral compounds using reversed-phase liquid chromatography coupled with capillary gas chromatography
    del Castillo, MLR
    Caballero, EG
    Herraiz, M
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2003, 41 (01) : 26 - 30