A METHOD FOR PRECISE CALIBRATION OF ELECTRON-BEAM ENERGY

被引:1
|
作者
GALUMIAN, P
JOSEPH, C
PERROUD, JP
TRAN, MT
WERLEN, M
机构
[1] University of Lausanne, IPN
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 1993年 / 327卷 / 2-3期
关键词
D O I
10.1016/0168-9002(93)90692-B
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A method for precise calibration of high energy electron beams is presented. The method is based on the kinematics of elastic scattering of the beam electrons by fixed target electrons. A conceptual setup is presented and the main sources of systematic errors are discussed. The feasibility of the method was investigated for LEP beams at the energies 46.5 and 80 GeV. The results obtained show that the beam energy at LEP can be measured with an accuracy of +/- (1-2) MeV in the energy range from 45 to 100 GeV.
引用
收藏
页码:269 / 276
页数:8
相关论文
共 50 条
  • [1] ENERGY DETERMINATION FOR ELECTRON-BEAM CALIBRATION
    FREIM, JO
    FELDMAN, A
    PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (03): : 361 - 365
  • [2] ELECTRON-BEAM CALIBRATION CONSTANTS
    LANE, RG
    LAKE, D
    RADIOLOGY, 1978, 126 (01) : 259 - 260
  • [3] A precise electron beam energy calibration for use in nuclear physics
    Zwart, T
    Alarcon, R
    Booth, E
    Dodson, G
    Dolfini, S
    Dow, K
    Farkhondeh, M
    Jacobs, K
    Joo, K
    Kowalski, S
    Soong, S
    Shaw, J
    Turchinetz, W
    Tsentalovich, E
    Wojtsekhowski, B
    Young, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 384 (2-3): : 299 - 306
  • [4] COMPARISONS OF ACCEPTANCE AND CALIBRATION OF A SCANNING ELECTRON-BEAM AND A SCATTERED ELECTRON-BEAM
    SWEENEY, LE
    JONES, D
    MEDICAL PHYSICS, 1985, 12 (04) : 533 - 533
  • [5] A RAPID METHOD FOR ELECTRON-BEAM ENERGY CHECK
    PISCIOTTA, VJ
    WU, XD
    FIEDLER, JA
    SERAGO, CF
    CALISHWATZICH, ML
    SCHWADE, JG
    HOUDEK, PV
    MEDICAL PHYSICS, 1992, 19 (06) : 1451 - 1453
  • [6] A SIMPLE METHOD FOR THE MEASUREMENT OF ELECTRON-BEAM ENERGY
    KNIZHNIK, EI
    MOSKALEV, VA
    ONISKO, AD
    SOVIET ATOMIC ENERGY, 1986, 60 (03): : 279 - 281
  • [7] FLOW CALORIMETRIC METHOD OF DETERMINING ELECTRON-BEAM ENERGY
    LOVELL, S
    SHEN, H
    PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (02): : 198 - 208
  • [8] ELECTRON-BEAM ENERGY DETERMINATION
    ALMOND, PR
    MEDICAL PHYSICS, 1985, 12 (04) : 534 - 534
  • [9] CALIBRATION OF THE HP ELECTRON-BEAM LITHOGRAPHY SYSTEM
    BUGELY, FL
    OSBORNE, IF
    OWEN, G
    SCHUDY, RB
    HEWLETT-PACKARD JOURNAL, 1981, 32 (05): : 27 - 33
  • [10] TOTAL-ABSORPTION CALORIMETER FOR MEDIUM-ENERGY ELECTRON-BEAM CALIBRATION
    SUNAGA, H
    TANAKA, R
    ALI, NM
    YOTSUMOTO, K
    RADIATION PHYSICS AND CHEMISTRY, 1995, 46 (4-6): : 1283 - 1286