SIMULTANEOUS ELECTROCHEMICAL MEASUREMENTS OF OXYGEN AND DOPAMINE INVIVO

被引:111
|
作者
ZIMMERMAN, JB [1 ]
WIGHTMAN, RM [1 ]
机构
[1] UNIV N CAROLINA,DEPT CHEM,CB 3290,VENABLE HALL,CHAPEL HILL,NC 27599
关键词
D O I
10.1021/ac00001a005
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Fast-scan cyclic voltammetry, a demonstrated analytical method for the in vivo detection of catecholamine neurotransmitters, is extended to the simultaneous determination of molecular oxygen (O2). Cyclic voltammograms were recorded at a scan rate of 400 V/s at carbon-fiber disk electrodes coated with a perfluorinated ion-exchange material. The peak current for O2 occurs near -1.2 V under these conditions. In flow-injection experiments, these electrodes respond to step changes in dopamine and O2 with a half-rise time of less than 200 ms. The voltammetric peak current is independent of flow rate, indicating a diffusion-limited response unaffected by convection. Several compounds present in the in vivo matrix (adenosine, glutathione, and NAD and glutamic, lactic, and uric acids) were tested and shown not to interfere with the voltammetric signal for O2. These electrodes maintain a stable response in vivo for at least 6 h. They have been used to measure transient increases in both dopamine and O2 in the extracellular fluid of the caudate nucleus of an anesthetized rat in response to an electrical stimulus.
引用
收藏
页码:24 / 28
页数:5
相关论文
共 50 条
  • [1] MEASUREMENTS INVIVO OF PARAMETERS OF THE DOPAMINE SYSTEM
    FRIEDMAN, AM
    DEJESUS, OT
    REVENAUGH, J
    DINERSTEIN, RJ
    ANNALS OF NEUROLOGY, 1984, 15 : S66 - S76
  • [2] INVIVO ELECTROCHEMICAL MEASUREMENTS IN THE CNS
    ADAMS, RN
    PROGRESS IN NEUROBIOLOGY, 1990, 35 (04) : 297 - 311
  • [3] SIMULTANEOUS ELECTROCHEMICAL AND MOSSBAUER MEASUREMENTS ON POLYMERIC IRON PHTHALOCYANINE OXYGEN ELECTRODES
    BLOMQUIST, J
    HELGESON, U
    MOBERG, LC
    JOHANSSON, LY
    LARSSON, R
    ELECTROCHIMICA ACTA, 1982, 27 (10) : 1453 - 1460
  • [4] Dual electrochemical microsensor for simultaneous measurements of nitric oxide and oxygen: Fabrication and characterization
    Park, Sarah S.
    Tatum, Clarissa E.
    Lee, Youngmi
    ELECTROCHEMISTRY COMMUNICATIONS, 2009, 11 (10) : 2040 - 2043
  • [5] SIMULTANEOUS RADIOENZYMATIC ASSAY OF DOPAMINE AND DIHYDROXYPHENYLACETIC ACID - AN INDEX OF INVIVO DOPAMINE RELEASE
    CHENG, CH
    WOOTEN, GF
    JOURNAL OF PHARMACOLOGICAL METHODS, 1981, 5 (02): : 165 - 173
  • [6] MEASUREMENTS OF PERTINENT CONCENTRATIONS OF OXYGEN INVIVO
    SWARTZ, HM
    BOYER, S
    GAST, P
    GLOCKNER, JF
    HU, H
    LIU, KJ
    MOUSSAVI, M
    NORBY, SW
    VAHIDI, N
    WALCZAK, T
    WU, M
    CLARKSON, RB
    MAGNETIC RESONANCE IN MEDICINE, 1991, 20 (02) : 333 - 339
  • [7] INVIVO ELECTROCHEMICAL DETERMINATION OF DOPAMINE RELEASE IN RAT NEOSTRIATUM
    GONON, F
    CESPUGLIO, R
    PONCHON, JL
    BUDA, M
    JOUVET, M
    ADAMS, RN
    PUJOL, JF
    COMPTES RENDUS HEBDOMADAIRES DES SEANCES DE L ACADEMIE DES SCIENCES SERIE D, 1978, 286 (16): : 1203 - 1206
  • [8] A NOVEL ELECTROCHEMICAL METHOD FOR ESTIMATING MAXIMAL DOPAMINE UPTAKE INVIVO
    NG, JP
    LIEM, BJ
    JUSTICE, JB
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1991, 201 : 122 - ANYL
  • [9] Developing an electrochemical sensor for the in vivo measurements of dopamine
    Delmo, Naela
    Mostafiz, Bahar
    Ross, Ashley E.
    Suni, Johanna
    Peltola, Emilia
    SENSORS & DIAGNOSTICS, 2023, 2 (03): : 559 - 581
  • [10] Simultaneous electrochemical determination of dopamine, melatonin, methionine and caffeine
    Molaakbari, Elahe
    Mostafavi, Ali
    Beitollahi, Hadi
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 208 : 195 - 203