A COMPARISON OF THE CAFFEINE HALOTHANE MUSCLE CONTRACTURE TEST WITH THE MOLECULAR GENETIC DIAGNOSIS OF MALIGNANT HYPERTHERMIA

被引:29
|
作者
MACKENZIE, AE
ALLEN, G
LAHEY, D
CROSSAN, ML
NOLAN, K
METTLER, G
WORTON, RG
MACLENNAN, DH
KORNELUK, R
机构
[1] UNIV OTTAWA,OTTAWA CIVIC HOSP,DEPT ANESTHESIA,OTTAWA K1N 6N5,ONTARIO,CANADA
[2] UNIV TORONTO,HOSP SICK CHILDREN,DEPT GENET,TORONTO M5G 1X8,ONTARIO,CANADA
[3] UNIV TORONTO,DEPT MED GENET,TORONTO M5S 1A1,ONTARIO,CANADA
[4] UNIV TORONTO,BANTING & BEST DEPT MED RES,TORONTO M5S 1A1,ONTARIO,CANADA
关键词
MALIGNANT HYPERTHERMIA GENETIC LINKAGE; RYANODINE; RECEPTOR GENE MEASUREMENT TECHNIQUES; CAFFEINE HALOTHANE CONTRACTURE TEST;
D O I
10.1097/00000542-199107000-00002
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Malignant hyperthermia (MH) is currently diagnosed by the caffeine-halothane contracture (CHC) test. In a previous study, this test was used to establish linkage between the human gene for MH susceptibility and the ryanodine receptor (RYR) gene. The current study extends the genetic linkage analysis to a large French-Canadian kindred. In this family, genetic linkage between RYR and MH genes was not demonstrable using the currently recommended limits of normal for the CHC test in the identification of MH-susceptible individuals. With CHC test threshold limits below those currently recommended, however, complete linkage between the RYR and MH genes was seen. Comparisons of CHC test results with genetic linkage studies will increase the diagnostic accuracy of both tests as well as generate new insights into the biology of MH.
引用
收藏
页码:4 / 8
页数:5
相关论文
共 50 条
  • [1] Use of the caffeine-halothane contracture test for the diagnosis of malignant hyperthermia in Brazil
    Sudo, R. T.
    Cunha, L. B. P.
    Carmo, P. L.
    Matos, A. R.
    Trachez, M. M.
    Cardoso, L. A. M.
    Aguiar, M. I. S.
    Abreu, A. V.
    Zapata-Sudo, G.
    BRAZILIAN JOURNAL OF MEDICAL AND BIOLOGICAL RESEARCH, 2010, 43 (06) : 549 - 556
  • [2] COMPARISON OF THE CAFFEINE SKINNED FIBER TENSION (CSFT) TEST WITH THE CAFFEINE-HALOTHANE CONTRACTURE (CHC) TEST IN THE DIAGNOSIS OF MALIGNANT HYPERTHERMIA
    BRITT, BA
    FRODIS, W
    SCOTT, E
    CLEMENTS, MJ
    ENDRENYI, L
    CANADIAN ANAESTHETISTS SOCIETY JOURNAL, 1982, 29 (06) : 550 - 562
  • [3] Diagnosis of malignant hyperthermia: A comparison of the in vitro contracture test with the molecular genetic diagnosis in a large pedigree
    Healy, JMS
    Quane, KA
    Keating, KE
    Lehane, M
    Heffron, JJA
    McCarthy, TV
    JOURNAL OF MEDICAL GENETICS, 1996, 33 (01) : 18 - 24
  • [4] NEUROLEPTIC MALIGNANT SYNDROME AND MALIGNANT HYPERTHERMIA - INVITRO COMPARISON WITH HALOTHANE AND CAFFEINE CONTRACTURE TESTS
    KRIVOSICHORBER, R
    ADNET, P
    GUEVART, E
    THEUNYNCK, D
    LESTAVEL, P
    BRITISH JOURNAL OF ANAESTHESIA, 1987, 59 (12) : 1554 - 1556
  • [5] FALSE-NEGATIVE RESULTS WITH MUSCLE CAFFEINE HALOTHANE CONTRACTURE TESTING FOR MALIGNANT HYPERTHERMIA
    ISAACS, H
    BADENHORST, M
    ANESTHESIOLOGY, 1993, 79 (01) : 5 - 9
  • [6] Caffeine-halothane contracture test and pharmacogenomics screening for investigation of malignant hyperthermia susceptibility
    Martinez de Soto, Lucia
    Rodriguez Mariblanca, Amelia
    Garcia Garcia, Irene
    Diaz Garcia, Lucia
    Queiruga Parada, Javier
    Monserrat Villatoro, Jaime
    Borobia Perez, Alberto M.
    Ramirez Garcia, Elena
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2018, 123 : 42 - 42
  • [7] STANDARDIZATION OF THE CAFFEINE HALOTHANE MUSCLE CONTRACTURE TEST
    LARACH, MG
    ANESTHESIA AND ANALGESIA, 1989, 69 (04): : 511 - 515
  • [8] SOURCES OF VARIABILITY IN HALOTHANE AND CAFFEINE CONTRACTURE TESTS FOR SUSCEPTIBILITY TO MALIGNANT HYPERTHERMIA
    ORDING, H
    BENDIXEN, D
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 1992, 9 (05) : 367 - 376
  • [9] COMPARISON OF INVITRO CONTRACTURE TESTING WITH RYANODINE, HALOTHANE AND CAFFEINE IN MALIGNANT HYPERTHERMIA AND OTHER NEUROMUSCULAR DISORDERS
    HOPKINS, PM
    ELLIS, FR
    HALSALL, PJ
    BRITISH JOURNAL OF ANAESTHESIA, 1993, 70 (04) : 397 - 401
  • [10] Malignant hyperthermia (MH) diagnostics: A comparison between the halothane-caffeine- and the ryanodine-contracture-test results in MH susceptible, normal and control muscle
    Hartung, E
    Koob, M
    Anetseder, M
    Schoemig, P
    Krauspe, R
    Hogrefe, G
    Engelhardt, W
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1996, 40 (04) : 437 - 444