WIND INDUCED RESPONSE OF A CABLE SUPPORTED STADIUM ROOF

被引:10
|
作者
VICKERY, BJ [1 ]
MAJOWIECKI, M [1 ]
机构
[1] STUDIO TECN MAJOWIECKI,CASALECCHIO RENO,ITALY
关键词
D O I
10.1016/0167-6105(92)90152-Z
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The first section of the paper describes the results of a wind tunnel investigation of the behaviour of wind of the cable supported roof of the "Stadio delle Alpi", Turin, Italy. The results presented and discussed include local and area-averaged pressures on the roof and the motions observed on a 1:200 aeroelastic model. It is shown that the major part of the loading is dynamic in nature and is due to vortices formed in the wake of the upstream sector of the roof and producing vertical velocity fluctuations in the flow approaching the leading edge of the downstream sector. The second section of the paper is concerned with the difficulties of presenting the experimental data to the designer in a form which could be readily brought into the design and analysis process and to the discussion of improved experimental techniques which might surmount those difficulties in future studies of similar structures. The improved approach involves the use of a multi-point high speed pressure scanning system and the formation of a suitable set of load pattern time histories.
引用
收藏
页码:1447 / 1458
页数:12
相关论文
共 50 条
  • [1] Wind tunnel tests of a cable supported roof of a stadium
    Józwiak, R
    Kacprzyk, J
    Zuranski, JA
    WIND ENGINEERING INTO THE 21ST CENTURY, VOLS 1-3, 1999, : 1511 - 1517
  • [2] Steel Cable Roof Stadium Halt
    不详
    STAHL UND EISEN, 2010, 130 (07): : 81 - 81
  • [3] Cable Erection of Krasnodar Stadium Suspended Roof
    Lombardini, Daniela
    Geyer, Silvia
    TENSINET - COST TU1303 INTERNATIONAL SYMPOSIUM 2016 - NOVEL STRUCTURAL SKINS - IMPROVING SUSTAINABILITY AND EFFICIENCY THROUGH NEW STRUCTURAL TEXTILE MATERIALS AND DESIGNS, 2016, 155 : 407 - 415
  • [4] Wind-induced vibration response and parametric analysis of the cable-net stadium roofs
    Ren, Tao
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2010, 31 (SUPPL. 2): : 137 - 141
  • [5] Stadium roof features cable-stay design
    不详
    CIVIL ENGINEERING, 2000, 70 (05): : 21 - 21
  • [6] WIND RESPONSE OF A LARGE TENSILE STRUCTURE - THE NEW ROOF OF THE OLYMPIC STADIUM IN ROME
    BORRI, C
    MAJOWIECKI, M
    SPINELLI, P
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1992, 42 (1-3) : 1435 - 1446
  • [7] Shielding and wind direction effects on wind-induced response of cable-supported photovoltaic array
    Ding, Hao
    He, Xuhui
    Jing, Haiquan
    Wu, Xiaoping
    Weng, Xiaojun
    ENGINEERING STRUCTURES, 2024, 309
  • [8] Erection of the cable net roof for the London 2012 Olympic Stadium
    Watson Steel Structures Ltd., 60 Newman St., London, W1T 3DA, United Kingdom
    不详
    Struct. Congr. - Proc. Struct. Congr., (304-313):
  • [9] Assessment of Cable Forces at the London 2012 Olympic Stadium Roof
    Caetano, Elsa de Sa
    Bartek, Rastislav
    Magalhaes, Filipe
    Keenan, Chris
    Trippick, Glyn
    STRUCTURAL ENGINEERING INTERNATIONAL, 2013, 23 (04) : 489 - 500
  • [10] Wind-induced responses of a stadium canopy roof based on non-steady wind pressure
    Zhou, Xuanyi
    Gu, Ming
    Huang, Youqin
    Shang, Chengzhi