PERFORMANCE OF LOCALLY PRODUCED COLD-FORMED STEEL SECTIONS FOR ROOF TRUSS SYSTEM

被引:0
|
作者
Mahmood, M. T. [1 ]
Thong, C. M. [1 ]
Tan, C. S. [1 ]
机构
[1] Univ Teknol Malaysia, Fac Civil Engn, Steel Technol Ctr, Skudai 81310, Johor, Malaysia
来源
JURNAL TEKNOLOGI | 2005年 / 42卷
关键词
Cold-formed steel section; roof truss system; section capacities; C-section; hat-section;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Traditionally, timber is usually used for roof truss as a construction material. However, the use of timber is no longer popular recently due to the increase in cost, not environmental-friendly as more trees need to be cut, prone to termite attack, and lesser capacity compared with steel. Cold-formed steel section has been introduced in this paper for the construction of roof truss system as an alternative to timber truss. This paper describes experimental test results of the proposed cold-formed produced locally with the code of practice as prescribed by BS 5950 Part 5: 1987 for the use in roof truss system. The tests were also performed to meet the requirements that have been outlined by Public Works Department, Malaysia. The experimental results showed good agreement with BS 5950 Part 5. From the study it can be concluded that the proposed locally produced cold-formed steel sections and the connections are suitable to be used in the roof truss system provided that the design values should not be more than the experimental values.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Experimental Investigation on Wide-span Cold-formed Steel Roof Truss System
    Mohammad, Shahrin
    Tahir, Mahmood Md
    Tan, Cher-Siang
    Shek, Poi-Ngian
    PROGRESS IN STRUCTURE, PTS 1-4, 2012, 166-169 : 1304 - 1307
  • [2] Torsional restraint of roof sheeting on cold-formed steel hat sections
    Papangelis, John
    Li, Chong
    Yi, Liao
    Yue, Fangyuan
    THIN-WALLED STRUCTURES, 2025, 209
  • [3] Axial fatigue performance of cold-formed steel sections
    Hassan, SK
    Polyzois, D
    Morris, G
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1998, 124 (02): : 149 - 157
  • [4] Reliability Assessment of Cold-Formed Steel Roof Truss According to Random Factors in Vietnam
    Hoang, Bac An
    CIGOS 2021, EMERGING TECHNOLOGIES AND APPLICATIONS FOR GREEN INFRASTRUCTURE, 2022, 203 : 461 - 470
  • [5] Design optimisation for cold-formed steel residential roof truss using genetic algorithm
    Kok, Ka Yee
    Lau, Hieng Ho
    Thanh Duoc Phan
    Ting, TIina Chui Huon
    WORLD JOURNAL OF ENGINEERING, 2018, 15 (05) : 575 - 583
  • [6] PROPERTIES OF COLD-FORMED STEEL SECTIONS
    Dandens, Atis
    Kreilis, Janis
    Andersons, Guntis
    CIVIL ENGINEERING 11, 2011, 3 : 166 - 170
  • [7] Structure Analysis of Cold-Formed Steel Roof Truss Post Office Branches Loa Janan
    Pranoto, Y.
    Jepriani, S.
    2ND INTERNATIONAL CONFERENCE ON SUSTAINABLE INFRASTRUCTURE, 2020, 1625
  • [8] Full-scale proof load test of ultralite cold-formed steel roof truss
    Mei, C. C.
    Chiew, S. P.
    Toh, S. L.
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON STEEL, SPACE & COMPOSITE STRUCTURES, 2007, : 285 - +
  • [9] Behavior and design for component and system of cold-formed steel roof trusses
    Reda, M.
    Sharaf, T.
    ElSabbagh, A.
    ElGhandour, M.
    THIN-WALLED STRUCTURES, 2019, 135 : 21 - 32
  • [10] Destructive mechanism of large span cold-formed section roof truss
    Guo, YJ
    Li, K
    Du, XX
    ADVANCES IN STEEL STRUCTURES, VOLS I & II, PROCEEDINGS, 2002, : 453 - 459