REMOVAL OF BASE-LINE WANDER AND POWER-LINE INTERFERENCE FROM THE ECG BY AN EFFICIENT FIR FILTER WITH A REDUCED NUMBER OF TAPS

被引:220
|
作者
VANALSTE, JA
SCHILDER, TS
机构
关键词
D O I
10.1109/TBME.1985.325514
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
引用
收藏
页码:1052 / 1060
页数:9
相关论文
共 50 条
  • [1] REMOVAL OF BASE-LINE WANDER AND POWER-LINE INTERFERENCE FROM THE ECG BY AN EFFICIENT FIR FILTER WITH A REDUCED NUMBER OF TAPS.
    Van Alste, J.A.
    Schilder, T.S.
    1985, (BME-32)
  • [2] An efficient removal of power-line interference and baseline wander from ECG signals by employing Fourier decomposition technique
    Singhal, Amit
    Singh, Pushpendra
    Fatimah, Binish
    Pachori, Ram Bilas
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2020, 57
  • [3] INTEGER COEFFICIENT BANDPASS FILTER FOR THE SIMULTANEOUS REMOVAL OF BASE-LINE WANDER, 50 AND 100 HZ INTERFERENCE FROM THE ECG
    WARIAR, R
    ESWARAN, C
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1991, 29 (03) : 333 - 336
  • [4] Baseline Wander and Power-Line Interference Removal from ECG Signals Using Fourier Decomposition Method
    Singh, Pushpendra
    Srivastava, Ishita
    Singhal, Amit
    Gupta, Anubha
    MACHINE INTELLIGENCE AND SIGNAL ANALYSIS, 2019, 748 : 25 - 36
  • [5] Power-line interference and baseline wander elimination in ECG using VMD and EWT
    Mir, Haroon Yousuf
    Singh, Omkar
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2024, 27 (15) : 2111 - 2130
  • [6] Removal of power-line interference from the ECG: a review of the subtraction procedure
    Chavdar Levkov
    Georgy Mihov
    Ratcho Ivanov
    Ivan Daskalov
    Ivaylo Christov
    Ivan Dotsinsky
    BioMedical Engineering OnLine, 4
  • [7] Removal of power-line interference from the ECG: a review of the subtraction procedure
    Levkov, Chavdar
    Mihov, Georgy
    Ivanov, Ratcho
    Daskalov, Ivan
    Christov, Ivaylo
    Dotsinsky, Ivan
    BIOMEDICAL ENGINEERING ONLINE, 2005, 4 (1)
  • [8] AN IMPROVED FILTER FOR ECG BASE-LINE WANDER IN REAL-TIME ISCHEMIA MONITORING
    FRANKEL, RA
    POTTALA, EW
    BAILEY, JJ
    JOURNAL OF ELECTROCARDIOLOGY, 1993, 25 : 156 - 156
  • [9] Removal of the baseline wander and the power line interference from ECG signals using the Median-Kalman filter
    Nandi, Kiron
    Lahiri, Abhijit
    FOUNDATIONS AND FRONTIERS IN COMPUTER, COMMUNICATION AND ELECTRICAL ENGINEERING, 2016, : 415 - 419
  • [10] Quantitative analysis of errors due to power-line interference and base-line drift in detection of onsets and offsets in ECG using wavelets
    J. S. Sahambi
    S. N. Tandon
    R. K. P. Bhatt
    Medical and Biological Engineering and Computing, 1997, 35 : 747 - 751