DETERMINATION OF EPHEDRINE IN HUMAN URINE USING A GLASSY-CARBON ELECTRODE

被引:22
|
作者
CHICHARRO, M [1 ]
ZAPARDIEL, A [1 ]
BERMEJO, E [1 ]
PEREZ, JA [1 ]
HERNANDEZ, L [1 ]
机构
[1] UNIV AUTONOMA MADRID,DEPT ANALYT CHEM & INSTRUMENTAL ANAL,E-28049 MADRID,SPAIN
关键词
VOLTAMMETRY; EPHEDRINE; GLASSY CARBON ELECTRODES; PHARMACEUTICALS; URINE;
D O I
10.1016/0003-2670(93)80178-N
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrochemical behaviour of ephedrine at a glassy carbon electrode was studied using linear-sweep and differential-pulse voltammetry at a stationary electrode and a rotating disc electrode. The studies were performed using 0.04 M Britton-Robinson buffer (pH 10.0), which allowed the evaluation of the diffusion constant, the charge-transfer coefficient and the conditional charge-transfer rate constant. A method was also devised for the electrochemical determination of ephedrine in human urine samples using differential-pulse voltammetry with prior drug separation. If this separation method is applied, either calibration graphs or standard additions can be used to determine ephedrine at concentrations between 7 and 20 mug ml-1, with relative errors lower than 6.0% and relative standard deviations lower than 5.8%. The presence of norephedrine at levels 20% lower than those of ephedrine has no influence on ephedrine determination.
引用
收藏
页码:361 / 368
页数:8
相关论文
共 50 条
  • [1] VOLTAMMETRIC DETERMINATION OF TOTAL ALKANNIN USING A GLASSY-CARBON ELECTRODE
    CHAISUKSANT, R
    VOULGAROPOULOS, A
    MELLIDIS, AS
    PAPAGEORGIOU, VP
    ANALYST, 1993, 118 (02) : 179 - 182
  • [2] VOLTAMMETRIC DETERMINATION OF PENTACHLOROPHENOL AT A GLASSY-CARBON ELECTRODE
    GUIJARRO, EC
    YANEZSEDENO, P
    CARRAZON, JMP
    DIEZ, LMP
    ANALYST, 1988, 113 (04) : 625 - 627
  • [3] ELECTROCHEMICAL DETERMINATION OF ADRIAMYCIN USING PRECONCENTRATION BY ADSORPTION ON GLASSY-CARBON ELECTRODE
    HIRANO, S
    MASUJIMA, T
    YOSHIDA, H
    IMAI, H
    BUNSEKI KAGAKU, 1986, 35 (03) : 167 - 172
  • [4] GLUCOSE ELECTRODE USING GLASSY-CARBON AS BASE ELECTRODE
    MATSUMOTO, K
    YOSHIOKA, S
    NOMURA, T
    OSAJIMA, Y
    SCIENCE BULLETIN OF THE FACULTY OF AGRICULTURE KYUSHU UNIVERSITY, 1980, 34 (3-4): : 115 - 121
  • [5] VOLTAMMETRIC DETERMINATION OF COBALT(II) USING A GLASSY-CARBON WORKING ELECTRODE
    CAKRT, M
    BERCIK, J
    HLADKY, Z
    MATHIASOVA, A
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1981, 309 (05): : 397 - 398
  • [6] Stripping voltammetric determination of lead using a glassy-carbon electrode system
    V. A. Nevostruev
    I. K. Kilina
    O. N. Bulgakova
    Yu. I. Ivanov
    Journal of Analytical Chemistry, 2000, 55 : 70 - 71
  • [7] Stripping voltammetric determination of lead using a glassy-carbon electrode system
    Nevostruev, VA
    Kilina, IK
    Bulgakova, ON
    Ivanov, YI
    JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 55 (01) : 70 - 71
  • [8] VOLTAMMETRIC DETERMINATION OF PHENYLBUTAZONE AND OXYPHENBUTAZONE AT A GLASSY-CARBON ELECTRODE
    CHAN, HK
    FOGG, AG
    ANALYTICA CHIMICA ACTA, 1979, 109 (02) : 341 - 349
  • [9] AMPEROMETRIC DETERMINATION OF NITRITE BY OXIDATION AT A GLASSY-CARBON ELECTRODE
    NEWBERY, JE
    DEHADDAD, MPL
    ANALYST, 1985, 110 (01) : 81 - 82
  • [10] A GLASSY-CARBON ELECTRODE FOR VOLTAMMETRY
    ZITTEL, HE
    MILLER, FJ
    ANALYTICAL CHEMISTRY, 1965, 37 (02) : 200 - &