Comparison of 1D and 3D Models for the Estimation of Fractional Flow Reserve

被引:0
|
作者
P. J. Blanco
C. A. Bulant
L. O. Müller
G. D. Maso Talou
C. Guedes Bezerra
P. A. Lemos
R. A. Feijóo
机构
[1] National Laboratory for Scientific Computing,Department of Interventional Cardiology
[2] LNCC/MCTIC,undefined
[3] Av. Getúlio Vargas,undefined
[4] 333,undefined
[5] Heart Institute (InCor) and the University of São Paulo Medical School,undefined
[6] INCT-MACC Instituto Nacional de Ciência e Tecnologia em Medicina Assistida por Computação Científica,undefined
来源
关键词
Fractional Flow Reserve (FFR); Coronary Computed Tomography Angiography (CCTA); IVUS Images; Rest Coronary Blood Flow (RCBF); Hyperemic Coronary Blood Flow (HCBF);
D O I
暂无
中图分类号
学科分类号
摘要
In this work we propose to validate the predictive capabilities of one-dimensional (1D) blood flow models with full three-dimensional (3D) models in the context of patient-specific coronary hemodynamics in hyperemic conditions. Such conditions mimic the state of coronary circulation during the acquisition of the Fractional Flow Reserve (FFR) index. Demonstrating that 1D models accurately reproduce FFR estimates obtained with 3D models has implications in the approach to computationally estimate FFR. To this end, a sample of 20 patients was employed from which 29 3D geometries of arterial trees were constructed, 9 obtained from coronary computed tomography angiography (CCTA) and 20 from intra-vascular ultrasound (IVUS). For each 3D arterial model, a 1D counterpart was generated. The same outflow and inlet pressure boundary conditions were applied to both (3D and 1D) models. In the 1D setting, pressure losses at stenoses and bifurcations were accounted for through specific lumped models. Comparisons between 1D models (FFR1D) and 3D models (FFR3D) were performed in terms of predicted FFR value. Compared to FFR3D, FFR1D resulted with a difference of 0.00 ± 0.03 and overall predictive capability AUC, Acc, Spe, Sen, PPV and NPV of 0.97, 0.98, 0.90, 0.99, 0.82, and 0.99, with an FFR threshold of 0.8. We conclude that inexpensive FFR1D simulations can be reliably used as a surrogate of demanding FFR3D computations.
引用
收藏
相关论文
共 50 条
  • [1] Comparison of 1D and 3D Models for the Estimation of Fractional Flow Reserve
    Blanco, P. J.
    Bulant, C. A.
    Muller, L. O.
    Maso Talou, G. D.
    Guedes Bezerra, C.
    Lemos, P. L.
    Feijoo, R. A.
    SCIENTIFIC REPORTS, 2018, 8
  • [2] Author Correction: Comparison of 1D and 3D Models for the Estimation of Fractional Flow Reserve
    P. J. Blanco
    C. A. Bulant
    L. O. Müller
    G. D. Maso Talou
    C. Guedes Bezerra
    P. A. Lemos
    R. A. Feijóo
    Scientific Reports, 8
  • [3] Comparison of 1D and 3D Models for the Estimation of Fractional Flow Reserve (vol 8, 17275, 2018)
    Blanco, P. J.
    Bulant, C. A.
    Mueller, L. O.
    Maso Talou, G. D.
    Guedes Bezerra, C.
    Lemos, P. A.
    Feijoo, R. A.
    SCIENTIFIC REPORTS, 2018, 8
  • [4] Comparison of one-dimensional (1D) and three-dimensional (3D) models for the estimation of coronary fractional flow reserve through cardiovascular imaging
    Bezerra, Cristiano
    Lemos, Pedro A.
    Pinton, Fabio A.
    Mueller, Lucas
    Bulant, Carlos
    Talou, Gonzalo Maso
    Feijoo, Raul A.
    Filh Esteves, Antonio Esteves
    Blanco, Pablo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (13) : B248 - B248
  • [5] Global Sensitivity Analysis For Clinically Validated 1D Models of Fractional Flow Reserve
    Tanade, Cyrus
    Feiger, Bradley
    Vardhan, Madhurima
    Chen, S. James
    Leopold, Jane A.
    Randles, Amanda
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 4395 - 4398
  • [6] Comparison of fractional flow reserve value of patient-specific left anterior descending artery using 1D and 3D CFD analysis
    Saha, Supratim
    Purushotham, T.
    Prakash, K. Arul
    INTERNATIONAL JOURNAL OF ADVANCES IN ENGINEERING SCIENCES AND APPLIED MATHEMATICS, 2019, 11 (04) : 244 - 253
  • [7] Comparison of fractional flow reserve value of patient-specific left anterior descending artery using 1D and 3D CFD analysis
    Supratim Saha
    T. Purushotham
    K. Arul Prakash
    International Journal of Advances in Engineering Sciences and Applied Mathematics, 2019, 11 : 244 - 253
  • [8] A singularity removal method for coupled 1D–3D flow models
    Ingeborg G. Gjerde
    Kundan Kumar
    Jan M. Nordbotten
    Computational Geosciences, 2020, 24 : 443 - 457
  • [9] 1D and 3D models of auto-regulated cerebrovascular flow
    Moorhead, KT
    Moore, SM
    Chase, JG
    David, T
    Fink, J
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 726 - 729
  • [10] COMPARISON OF 3D IMAGING AND 1D DEPOSITION MODELS: AT WHICH DIMENSION?
    Katz, I.
    Pichelin, M.
    Majoral, C.
    Caillibotte, G.
    Montesantos, S.
    Bennett, M.
    Conway, J.
    Fleming, J.
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2013, 26 (05) : A6 - A6