Distal planar rotary scanner for endoscopic optical coherence tomography

被引:0
|
作者
Kyle Searles
Nabil Shalabi
Geoffrey Hohert
Nirvana Gharib
Sayed Mohammad Hashem Jayhooni
Pierre M. Lane
Kenichi Takahata
机构
[1] University of British Columbia,School of Biomedical Engineering
[2] University of British Columbia,Department of Electrical and Computer Engineering
[3] BC Cancer Research Institute,Integrative Oncology
来源
Biomedical Engineering Letters | 2024年 / 14卷
关键词
Optical scanner; Electromagnetic actuator; Ferrofluid; Endoscopic probe; Optical coherence tomography;
D O I
暂无
中图分类号
学科分类号
摘要
Optical coherence tomography (OCT) is becoming a more common endoscopic imaging modality for detecting and treating disease given its high resolution and image quality. To use OCT for 3-dimensional imaging of small lumen, embedding an optical scanner at the distal end of an endoscopic probe for circumferential scanning the probing light is a promising way to implement high-quality imaging unachievable with the conventional method of revolving an entire probe. To this end, the present work proposes a hollow and planar micro rotary actuator for its use as an endoscopic distal scanner. A miniaturized design of this ferrofluid-assisted electromagnetic actuator is prototyped to act as a full 360° optical scanner, which is integrated at the tip of a fiber-optic probe together with a gradient-index lens for use with OCT. The scanner is revealed to achieve a notably improved dynamic performance that shows a maximum speed of 6500 rpm, representing 325% of the same reported with the preceding design, while staying below the thermal limit for safe in-vivo use. The scanner is demonstrated to perform real-time OCT using human fingers as live tissue samples for the imaging tests. The acquired images display no shadows from the electrical wires to the scanner, given its hollow architecture that allows the probing light to pass through the actuator body, as well as the quality high enough to differentiate the dermis from the epidermis while resolving individual sweat glands, proving the effectiveness of the prototyped scanner design for endoscopic OCT application.
引用
收藏
页码:583 / 592
页数:9
相关论文
共 50 条
  • [1] Distal planar rotary scanner for endoscopic optical coherence tomography
    Searles, Kyle
    Shalabi, Nabil
    Hohert, Geoffrey
    Gharib, Nirvana
    Jayhooni, Sayed Mohammad Hashem
    Lane, Pierre M.
    Takahata, Kenichi
    BIOMEDICAL ENGINEERING LETTERS, 2024, 14 (03) : 583 - 592
  • [2] Polyimide amplified piezoelectric scanner for endoscopic optical coherence tomography
    Zara, Jason M.
    Patterson, Paul E.
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE X, 2006, 6079
  • [3] Endoscopic optical coherence tomography angiography using a piezo scanner
    Wurster, Lara M.
    Kretschmer, Simon
    Placzek, Fabian
    Vilches, Sergio
    Niederleithner, Michael
    Ataman, Caglar
    Zappe, Hans
    Leitgeb, Rainer A.
    2018 INTERNATIONAL CONFERENCE ON OPTICAL MEMS AND NANOPHOTONICS (OMN), 2018, : 201 - 202
  • [4] Integrated three-dimensional scanner for endoscopic optical coherence tomography
    Aljasem, Khaled
    Froehly, Luc
    Zappe, Hans
    Seifert, Andreas
    MICRO-OPTICS 2010, 2010, 7716
  • [5] Endoscopic optical coherence tomography
    Tearney, GJ
    Bouma, BE
    Brezinski, ME
    Boppart, SA
    Pitris, C
    Southern, JF
    Swanson, EA
    Fujimoto, JG
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE: THEORY, INSTRUMENTATION, MODEL, AND HUMAN STUDIES II, PROCEEDINGS OF, 1997, 2979 : 2 - 5
  • [6] Endoscopic optical coherence tomography angiography using a forward imaging piezo scanner probe
    Wurster, Lara M.
    Shah, Ronak N.
    Placzek, Fabian
    Kretschmer, Simon
    Niederleithner, Michael
    Ginner, Laurin
    Ensher, Jason
    Minneman, Michael P.
    Hoover, Erich E.
    Zappe, Hans
    Drexler, Wolfgang
    Leitgeb, Rainer A.
    Ataman, Caglar
    JOURNAL OF BIOPHOTONICS, 2019, 12 (04)
  • [7] Reproducibility of the Humphrey Optical Coherence Tomography Scanner
    Jones, AL
    Sheen, NJL
    North, RV
    Morgan, JE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S290 - S290
  • [8] Electro-thermal MEMS fiber scanner for endoscopic optical coherence tomography (Conference Presentation)
    Park, Hyeon-Cheol
    Zhang, Xiaoyang
    Mavadia-Shukla, Jessica
    Yuan, Wu
    Xie, Huikai
    Li, Xingde
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XX, 2016, 9697
  • [9] Endoscopic applications of optical coherence tomography
    Feldchtein, FI
    Gelikonov, GV
    Gelikonov, VM
    Kuranov, RV
    Sergeev, AM
    Gladkova, ND
    Shakhov, AV
    Shakhova, NM
    Snopova, LB
    Terent'eva, AB
    Zagainova, EV
    Chumakov, YP
    Kuznetzova, IA
    OPTICS EXPRESS, 1998, 3 (06): : 257 - 270
  • [10] FULL FINGERPRINT SCANNER USING OPTICAL COHERENCE TOMOGRAPHY
    Breithaupt, Ralph
    Sousedik, Ctirad
    Meissner, Sven
    2015 INTERNATIONAL WORKSHOP ON BIOMETRICS AND FORENSICS (IWBF), 2015,