Detection of hyperacute parenchymal hemorrhage of the brain using echo-planar T2*-weighted and diffusion-weighted MRI

被引:0
|
作者
Martin Wiesmann
Thomas E. Mayer
Indra Yousry
Gerhard F. Hamann
H. Brückmann
机构
[1] Department of Radiology,
[2] Medizinische Universität zu Lübeck,undefined
[3] 23538 Lübeck,undefined
[4] Germany,undefined
[5] Department of Neuroradiology,undefined
[6] Klinikum Grosshadern,undefined
[7] Ludwig-Maximilians-Universität,undefined
[8] 81377 München,undefined
[9] Germany Tel.: + 49-89-70 95 25 01 Fax: + 49–89–70952509,undefined
[10] Department of Neurology,undefined
[11] Klinikum Grosshadern,undefined
[12] Ludwig-Maximilians-Universität,undefined
[13] 81377 München,undefined
[14] Germany,undefined
来源
European Radiology | 2001年 / 11卷
关键词
Key words Intracerebral hemorrhage; Stroke; MR imaging; Echo-planar imaging; Diffusion-weighted imaging;
D O I
暂无
中图分类号
学科分类号
摘要
We investigated the usefulness of echo-planar imaging (EPI) as well as T2*-weighted and diffusion-weighted MRI (DWI) to identify hyperacute hemorrhage (within 24 h after ictus) in the brain. Seven patients were examined 3.5 to 24 h after onset of symptoms using a whole-body 1.5-T MR system. Two diffusion-weighted sequences were run to obtain isotropic and anisotropic diffusion images. Apparent diffusion coefficients (ADC) were calculated from the isotropic diffusion images. All DWI images as well as the T2*-weighted EPI images showed the hematomas as either discrete, deeply hypointense homogeneous lesions, or as lesions of mixed signal intensity containing hypointense areas. We conclude that even in the early phase after hemorrhage, sufficient amounts of paramagnetic deoxyhemoglobin are present in intracerebral hemorrhages to cause hypointensity on EPI T2*-weighted and DWI images; thus, use of ultrafast EPI allows identification of intracerebral hemorrhage.
引用
收藏
页码:849 / 853
页数:4
相关论文
共 50 条
  • [1] Detection of hyperacute parenchymal hemorrhage of the brain using echo-planar T2*-weighted and diffusion-weighted MRI
    Wiesmann, M
    Mayer, TE
    Yousry, I
    Hamann, GF
    Brückmann, H
    EUROPEAN RADIOLOGY, 2001, 11 (05) : 849 - 853
  • [2] Diffusion-weighted echo-planar MRI of lacunar infarcts
    Noguchi, K
    Nagayoshi, T
    Watanabe, N
    Kanazawa, T
    Toyoshima, S
    Morijiri, M
    Shojaku, H
    Shimizu, M
    Seto, H
    NEURORADIOLOGY, 1998, 40 (07) : 448 - 451
  • [3] Diffusion-weighted echo-planar MRI of lacunar infarcts
    K. Noguchi
    T. Nagayoshi
    N. Watanabe
    T. Kanazawa
    S. Toyoshima
    M. Morijiri
    H. Shojaku
    M. Shimizu
    H. Seto
    Neuroradiology, 1998, 40 : 448 - 451
  • [4] Hyperacute stroke: Evaluation with combined multisection diffusion-weighted and hemodynamically weighted echo-planar MR imaging
    Sorensen, AG
    Buonanno, FS
    Gonzalez, RG
    Schwamm, LH
    Lev, MH
    HuangHellinger, FR
    Reese, TG
    Weisskoff, RM
    Davis, TL
    Suwanwela, N
    Can, U
    Moreira, JA
    Copen, WA
    Look, RB
    Finklestein, SP
    Rosen, BR
    Koroshetz, WJ
    RADIOLOGY, 1996, 199 (02) : 391 - 401
  • [5] A prospective, longitudinal study of echo-planar T2*-weighted MRI for early detection of intracranial hemorrhage in premature infants
    Neil, JJ
    Benzinger, TLS
    Mathur, A
    Almli, CR
    McKinstry, RC
    ANNALS OF NEUROLOGY, 2003, 54 : S122 - S122
  • [6] Assessment of lacunar hemorrhage associated with hypertensive stroke by echo-planar gradient-echo T2*-weighted MRI
    Kinoshita, T
    Okudera, T
    Tamura, H
    Ogawa, T
    Hatazawa, J
    STROKE, 2000, 31 (07) : 1646 - 1650
  • [7] Detection of active multiple sclerosis lesions with T-2-weighted, echo planar, diffusion-weighted MRI
    Gass, A
    Marx, A
    Schreiber, W
    Gaa, J
    Schwartz, A
    Hennerici, MG
    ANNALS OF NEUROLOGY, 1997, 42 (03) : T298 - T298
  • [8] Usefulness of diffusion-weighted MRI with echo-planar technique in the evaluation of cellularity in gliomas
    Sugahara, T
    Korogi, Y
    Kochi, M
    Ikushima, I
    Shigematu, Y
    Hirai, T
    Okuda, T
    Liang, LX
    Ge, YL
    Komohara, Y
    Ushio, Y
    Takahashi, M
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 9 (01): : 53 - 60
  • [9] Comparison of Ferucarbotran-Enhanced Fluid-Attenuated Inversion-Recovery Echo-Planar, T2-Weighted Turbo Spin-Echo, T2*-Weighted Gradient-Echo, and Diffusion-Weighted Echo-Planar Imaging for Detection of Malignant Liver Lesions
    Fukukura, Yoshihiko
    Kamiyama, Takuro
    Takumi, Koji
    Shindo, Toshikazu
    Higashi, Ryutaro
    Nakajo, Masayuki
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (03) : 607 - 616
  • [10] Hemorrhagic and nonhemorrhagic stroke: Diagnosis with diffusion-weighted and T2-weighted echo-planar MR imaging
    Ebisu, T
    Tanaka, C
    Umeda, M
    Kitamura, M
    Fukunaga, M
    Aoki, I
    Sato, H
    Higuchi, T
    Naruse, S
    Horikawa, Y
    Ueda, S
    RADIOLOGY, 1997, 203 (03) : 823 - 828