Introduction to Grayscale Calibration and Related Aspects of Medical Imaging Grade Liquid Crystal Displays

被引:0
|
作者
Kenneth A. Fetterly
Hartwig R. Blume
Michael J. Flynn
Ehsan Samei
机构
[1] Mayo Clinic,Department of Diagnostic Radiology
[2] Henry Ford Health Systems,Department of Radiology
[3] Duke University Medical Center,Department of Radiology
[4] Duke University Medical Center,Department of Physics
[5] Duke University Medical Center,Department of Biomedical Engineering
来源
关键词
Medical imaging grade liquid crystal displays (LCDs); DICOM GSDF; observer perception; ambient light;
D O I
暂无
中图分类号
学科分类号
摘要
Consistent presentation of digital radiographic images at all locations within a medical center can help ensure a high level of patient care. Currently, liquid crystal displays (LCDs) are the electronic display technology of choice for viewing medical images. As the inherent luminance (and thereby perceived contrast) properties of different LCDs can vary substantially, calibration of the luminance response of these displays is required to ensure that observer perception of an image is consistent on all displays. The digital imaging and communication in medicine (DICOM) grayscale standard display function (GSDF) defines the luminance response of a display such that an observer’s perception of image contrast is consistent throughout the pixel value range of a displayed image. The main purpose of this work is to review the theoretical and practical aspects of calibration of LCDs to the GSDF. Included herein is a review of LCD technology, principles of calibration, and other practical aspects related to calibration and observer perception of images presented on LCDs. Both grayscale and color displays are considered, and the influence of ambient light on calibration and perception is discussed.
引用
收藏
页码:193 / 207
页数:14
相关论文
共 50 条
  • [1] Introduction to grayscale calibration and related aspects of medical imaging grade liquid crystal displays
    Fetterly, Kenneth A.
    Blume, Hartwig R.
    Flynn, Michael J.
    Samei, Ehsan
    JOURNAL OF DIGITAL IMAGING, 2008, 21 (02) : 193 - 207
  • [2] Mechanism of grayscale generation in antiferroelectric liquid crystal displays
    Sabater, J
    Rodrigo, C
    Quintana, X
    Oton, JM
    MOLECULAR CRYSTALS AND LIQUID CRYSTALS SCIENCE AND TECHNOLOGY SECTION A-MOLECULAR CRYSTALS AND LIQUID CRYSTALS, 1997, 303 : 187 - 192
  • [3] Effect of angular performance on the chromaticity of grayscale images displayed on medical liquid-crystal displays
    Akamine H.
    Morishita J.
    Matsuyama M.
    Hashimoto N.
    Nakamura Y.
    Yabuuchi H.
    Radiological Physics and Technology, 2013, 6 (1) : 61 - 69
  • [4] On the color calibration of liquid crystal displays
    Cazes, A
    Braudaway, G
    Christensen, J
    Cordes, M
    DeCain, D
    Lien, A
    Mintzer, F
    Wright, SL
    FLAT PANEL DISPLAY TECHNOLOGY AND DISPLAY METROLOGY, 1999, 3636 : 154 - 161
  • [5] Investigation of the Contrast Ratio Required for Medical-Grade Liquid-Crystal Displays
    Takarabe, S.
    Akamine, H.
    Yabuuchi, H.
    Nakamura, Y.
    Hashimoto, N.
    Morishita, J.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [6] Effects of the DICOM Grayscale Standard Display Function on the Accuracy of Medical-grade Grayscale and Consumer-grade Color Displays for Telemammography Screening
    Salazar, Antonio J.
    Romero, Javier
    Bernal, Oscar
    Moreno, Angela
    Velasco, Sofia
    Diaz, Xavier
    IX INTERNATIONAL SEMINAR ON MEDICAL INFORMATION PROCESSING AND ANALYSIS, 2013, 8922
  • [7] Liquid-crystal displays for medical imaging: a discussion of monochrome versus color
    Wright, SL
    Samei, E
    MEDICAL IMAGING 2004: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2004, 5367 : 444 - 455
  • [8] Liquid crystal beyond displays: feature introduction
    Lin, Yi-Hsin
    Hu, Wei
    Lin, Tsung-Hsien
    d'Alessandro, Antonio
    OPTICS EXPRESS, 2019, 27 (15) : 20785 - 20786
  • [9] Implementation of a color calibration method for liquid crystal displays
    Cazes, A
    Mintzer, F
    FLAT PANEL DISPLAY TECHNOLOGY AND DISPLAY METROLOGY II, 2001, 4295 : 267 - 278
  • [10] Temporal response of medical liquid crystal displays
    Liang, Hongye