Multimodal particle size distributions emitted from HFA-134a solution pressurized metered-dose inhalers

被引:0
|
作者
Hugh D. C. Smyth
机构
[1] University of North Carolina at Chapel Hill,School of Pharmacy
关键词
metered-dose inhaler; particle size distribution; laser diffraction; HFA-134a; cascade impaction; atomization;
D O I
10.1208/pt040338
中图分类号
学科分类号
摘要
The purpose of this research was to investigate the measurement and in vitro delivery implications of multimodal distributions, occurring near or in the respirable range, emitted from pressurized metered-dose inhalers (pMDIs). Particle size distributions of solution pMDIs containing hydrofluoroalkane-134a (HFA-134a) and ethanol were evaluated using 2 complementary particle-sizing methods: laser diffraction (LD) and cascade impaction (CI). Solution pMDIs were formulated from mixtures of HFA-134a (50%–97.5% wt/wt) and ethanol. A range of propellant concentrations was selected for a range of vapor pressures. The fluorescent probe, Rhodamine B, was included for chemical analysis. The complementary nature of LD and CI allowed identification of 2 dominant particle size modes at 1 and 10 μm or greater. Increasing propellant concentrations resulted in increases in the proportion of the size distributions at the 1-μm mode and also reduced the particle size of the larger droplet population. Despite significant spatial differences and time scales of measurement between the particle-sizing techniques, the fine particle fractions obtained from LD and CI were practically identical. This was consistent with LD experiments, which showed that particle sizes did not decrease with increasing measurement distance, and may be explained by the absence of significant evaporation/disintegration of larger droplets. The fine particle fractions (FPFs) emitted from HFA-134a/ethanol solution pMDI can be predicted on the basis of formulation parameters and is independent of measurement technique. These results highlight the importance of presenting particle size distribution data from complementary particle size techniques.
引用
收藏
相关论文
共 50 条
  • [1] ACUTE SAFETY OF THE CFC-FREE PROPELLANT HFA-134A FROM A PRESSURIZED METERED-DOSE INHALER
    DONNELL, D
    HARRISON, LI
    WARD, S
    KLINGER, NM
    EKHOLM, BP
    COOPER, KM
    PORIETIS, I
    MCEWEN, J
    EUROPEAN JOURNAL OF CLINICAL PHARMACOLOGY, 1995, 48 (06) : 473 - 477
  • [2] Fluticasone propionate HFA-134a pressurized metered-dose inhaler in adolescents and adults with moderate to severe asthma
    Pinnas, JL
    Noonan, MJ
    Weinstein, SF
    Chervinsky, P
    Scott, CA
    Herje, NE
    Wu, W
    Crim, C
    JOURNAL OF ASTHMA, 2005, 42 (10) : 865 - 871
  • [3] Relationship Between Geometric and Aerodynamic Particle Size Distributions in the Formulation of Solution and Suspension Metered-Dose Inhalers
    Hiroyuki Yoshida
    Akiko Usui
    Yasuhiro Abe
    Yukihiro Goda
    Ken-ichi Izutsu
    AAPS PharmSciTech, 21
  • [4] Relationship Between Geometric and Aerodynamic Particle Size Distributions in the Formulation of Solution and Suspension Metered-Dose Inhalers
    Yoshida, Hiroyuki
    Usui, Akiko
    Abe, Yasuhiro
    Goda, Yukihiro
    Izutsu, Ken-ichi
    AAPS PHARMSCITECH, 2020, 21 (05)
  • [5] SIZE DISTRIBUTIONS AND LUNG DEPOSITION OF SUBMICROMETER PARTICLES FROM METERED-DOSE INHALERS
    LIN, RH
    WANG, CR
    LI, CS
    ENVIRONMENT INTERNATIONAL, 1994, 20 (02) : 161 - 167
  • [6] The effect of dose on the characterization of aerodynamic particle-size distributions of beclomethasone dipropionate metered-dose inhalers
    El-Araud, KA
    Clark, BJ
    Kaahwa, C
    Anum, P
    Chrystyn, H
    JOURNAL OF PHARMACY AND PHARMACOLOGY, 1998, 50 (10) : 1081 - 1085
  • [7] AEROSOL-PARTICLE GENERATION FROM DRY POWDER INHALERS - CAN THEY EQUAL PRESSURIZED METERED-DOSE INHALERS
    OLSSON, B
    JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1995, 8 : S13 - S19
  • [8] FORMULATION OF SOLUTION METERED-DOSE INHALERS AND COMPARISON WITH AEROSOLS EMITTED FROM CONVENTIONAL SUSPENSION SYSTEMS
    WARREN, SJ
    FARR, SJ
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1995, 124 (02) : 195 - 203
  • [9] Metered-dose inhalers .2. Particle size measurement variation
    LeBelle, MJ
    Graham, SJ
    Ormsby, ED
    Duhaime, RM
    Lawrence, RC
    Pike, RK
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1997, 151 (02) : 209 - 221
  • [10] The Evolution of Pressurized Metered-Dose Inhalers from Early to Modern Devices
    Roche, Nicolas
    Dekhuijzen, P. N. Richard
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2016, 29 (04) : 311 - 327