Mitral valve replacement using bileaflet mechanical prosthetic valve in the first year of life

被引:0
|
作者
Masuda M. [1 ]
Kado H. [1 ,2 ]
Matsumoto T. [1 ,2 ]
Imoto Y. [1 ,2 ]
Shiokawa Y. [1 ,2 ]
Fukae K. [1 ,2 ]
Ushinohama D. [1 ,3 ]
Yasui H. [1 ]
机构
[1] Department of Cardiac Surgery, Kyushu University Hospital, Fukuoka, 812-8582, 3-1-1 Maidashi, Higashi-ku
[2] Department of Cardiovascular Surgery, Fukuoka Children’s Hospital, Fukuoka
[3] Department of Pediatric Cardiology, Fukuoka Children’s Hospital, Fukuoka
来源
The Japanese Journal of Thoracic and Cardiovascular Surgery | 2000年 / 48卷 / 10期
关键词
mitral valve replacement; infant; mechanical prosthetic valve; CarboMedics prosthetic heart valve; St. Jude Medical prosthetic heart valve;
D O I
10.1007/BF03218220
中图分类号
学科分类号
摘要
OBJECTIVE: The operative management and long term outcome of mitral valve replacement in infancy remain a therapeutic challenge. The selection of a prosthetic valve for this particular age group might affect the clinical outcome. Here we present our experience of mitral valve replacement in 6 infants using small bileaflet mechanical prosthetic valves. METHODS: Between January 1994 and August 1997, 6 infants (their age ranged from 3 months to 11 months, and their body weight from 2978 g to 7403 g) underwent mitral valve replacement using a mechanical valve prosthesis (16 mm CarboMedics prosthetic valve in 5, and 17 mm St. Jude Medical prosthetic valve Hemodynamic Plus in 1). The preoperative morphological features of the mitral valve were stenosis in 1, regurgitation in 3, and a combination of these in 2. The prosthesis was fixed at the annulus in 3, and at the supra-annular position in 3. Anticoagulation was performed using warfarin. RESULTS: There was no operative mortality. Postoperative catheterization revealed an acceptable wedge pressure in the pulmonary arteries, ranging from 10 to 12 mmHg. During the mean follow-up period of 36 months, late death due to residual pulmonary hypertension occurred in 1 patient at 10 months after surgery. Excluding this patient, all remaining patients are doing well with no need for repeated operation with no thromboembolic complication. The actuarial survival rate and the reoperation free rate at 70 months are 83 +/- 15% and 100%, respectively. CONCLUSION: Mitral valve replacement using a small size bileaflet mechanical prosthetic valves in infancy can be performed with low operative mortality and with satisfactory mid-term results.
引用
收藏
页码:643 / 647
页数:4
相关论文
共 50 条
  • [1] Outcomes of mitral valve replacement with bileaflet mechanical prosthetic valve in children
    Okamoto, Takuya
    Nakano, Toshihide
    Goda, Masami
    Oda, Shinichiro
    Kado, Hideaki
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2020, 68 (06) : 571 - 577
  • [2] Outcomes of mitral valve replacement with bileaflet mechanical prosthetic valve in children
    Takuya Okamoto
    Toshihide Nakano
    Masami Goda
    Shinichiro Oda
    Hideaki Kado
    General Thoracic and Cardiovascular Surgery, 2020, 68 : 571 - 577
  • [3] Intermediate-term results after the aortic valve replacement using bileaflet mechanical prosthetic valve in children
    Masuda, Munetaka
    Kado, Hideaki
    Ando, Yusuke
    Shiose, Akira
    Nakano, Toshihide
    Fukae, Kouji
    Tanoue, Yoshihisa
    Tominaga, Ryuji
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2008, 34 (01) : 42 - 47
  • [4] PROSTHETIC REPLACEMENT OF MITRAL VALVE
    BARNARD, CN
    HOLMGREN, LV
    SCHRIRE, V
    GOOSEN, CC
    LANCET, 1962, 2 (7265): : 1087 - &
  • [5] Tricuspid Valve Replacement Using a Bileaflet Mechanical Valve: 35 Years of Experience
    Shojima, Takahiro
    Arinaga, Koichi
    Akasu, Koji
    Takaseya, Tohru
    Takagi, Kazuyoshi
    Kikusaki, Satoshi
    Tanaka, Hiroyuki
    CARDIOLOGY, 2016, 134 (02) : 225 - 225
  • [6] Prosthetic valve thrombosis in a patient with mitral valve replacement
    Bilal, Muhammad
    Khan, Muhammad Shahzeb
    Haseeb, Abdul
    Khan, Abdul Bari
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2015, 65 (07) : 802 - 803
  • [7] Thrombotic occlusion of a bileaflet, mechanical mitral valve
    Pybus, David A.
    ANESTHESIA AND ANALGESIA, 2007, 105 (06): : 1567 - 1568
  • [8] A tilted prosthetic mitral valve decade after mitral valve replacement
    Kalyani, Maulik
    Sharma, Vishal
    Kothari, Shyam S.
    ASIAN CARDIOVASCULAR & THORACIC ANNALS, 2023, 31 (09): : 819 - 820
  • [9] EXPERIENCE WITH PROSTHETIC MITRAL VALVE REPLACEMENT
    GRADEL, E
    BURKART, F
    VONBERTR.R
    WOLFF, G
    SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 1968, 98 (33) : 1265 - &
  • [10] PROSTHETIC REPLACEMENT OF MITRAL VALVE IN ELDERLY
    GOULD, L
    WEBER, DJ
    SCHAFFER, AI
    JOURNAL OF CARDIOVASCULAR SURGERY, 1966, 7 (02): : 166 - &