A microbubble agent improves the therapeutic efficiency of high intensity focused ultrasound: a rabbit kidney study

被引:0
|
作者
Tinghe Yu
Guoyun Wang
Kai Hu
Ping Ma
Jin Bai
Zhibiao Wang
机构
[1] Chongqing Medical University,Institute of Ultrasound Engineering in Medicine
[2] Shandong University,Institute of Developmental Biology, College of Life Science
来源
Urological Research | 2004年 / 32卷
关键词
High intensity focused ultrasound; Microbubble agent; Kidney; Therapeutic efficiency; Acoustic characteristics of tissue;
D O I
暂无
中图分类号
学科分类号
摘要
Eighty kidneys (40 left and 40 right kidneys) of New Zealand rabbits were ablated using high intensity focused ultrasound (HIFU), (14,300 W/cm2, 1.0 MHz). Kidneys were randomly divided into two groups. HIFU was performed in the manner of linear scan in both groups. Prior to HIFU, normal saline solution and isovolumetric microbubble agent were administrated intravenously in groups I and II, respectively. HIFU was finished in all left kidneys and in 26/40 right ones. The therapeutic efficiency was reflected using necrosis rate (cubic centimeters per second), which was the tissue volume of coagulative necrosis per 1 s HIFU exposure. In both groups, predetermined volumes were damaged without harming overlying tissues. Necrosis rates were increased in group II both in left (0.0089±0.0107 vs. 0.0493±0.0777, P=0.0323) and in right (0.0039±0.0055 vs. 0.0162±0.0168, P=0.0248) kidneys. Pathological examinations confirmed that there were no intact tissue focuses within exposed regions in either group. These findings suggested that the microbubble agent improved the therapeutic efficiency of HIFU. Hemorrhage and hyperemia were also detected on the margin of the ablated tissues (both in cortex and medulla) in both groups.
引用
收藏
页码:14 / 19
页数:5
相关论文
共 50 条
  • [1] A microbubble agent improves the therapeutic efficiency of high intensity focused ultrasound: a rabbit kidney study
    Yu, TH
    Wang, GY
    Hu, K
    Ma, P
    Bai, J
    Wang, ZB
    UROLOGICAL RESEARCH, 2004, 32 (01): : 14 - 19
  • [2] Microbubble contrast agent SonoVue combined with oxytocin improves the efficiency of high-intensity focused ultrasound ablation for adenomyosis
    Yao, Ruihong
    Zhao, Wei
    Gao, Bulang
    Hu, Jihong
    Wang, Tao
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2021, 38 (01) : 1601 - 1608
  • [3] Erythrocytes and microbubble contrast agents, improve the therapeutic efficiency of high intensity focused ultrasound
    Takegami, K
    Kaneko, Y
    Watanabe, T
    Maruyama, T
    Matsumoto, Y
    Nagawa, H
    4th International Symposium on Therapeutic Ultrasound, 2005, 754 : 217 - 219
  • [4] The use of a microbubble agent to enhance rabbit liver destruction using high intensity focused ultrasound
    Yu, TH
    Xiong, SH
    Mason, TJ
    Wang, ZB
    ULTRASONICS SONOCHEMISTRY, 2006, 13 (02) : 143 - 149
  • [5] Effect of microbubble contrast agent during high intensity focused ultrasound ablation on rabbit liver in vivo
    Chung, Dong Jin
    Cho, Se Hyun
    Lee, Jae Mun
    Hahn, Seong-Tae
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (04) : E519 - E523
  • [6] Use of a microbubble agent to increase the therapeutic effects of high intensity focused ultrasound on experimental liver tumors
    Hanajiri, K
    Maruyama, T
    Kaneko, Y
    Mitsui, H
    Watanabe, S
    Omata, M
    Ikeda, Y
    Hashimoto, N
    Yamada, H
    Matsumoto, Y
    HEPATOLOGY, 2005, 42 (04) : 309A - 309A
  • [7] Use of a microbubble agent to increase the effects of high intensity focused ultrasound on liver tissue
    Yukio Kaneko
    Toshiyuki Maruyama
    Kenji Takegami
    Toshiaki Watanabe
    Hiroshi Mitsui
    Kazuyuki Hanajiri
    Hirokazu Nagawa
    Yoichiro Matsumoto
    European Radiology, 2005, 15 : 1415 - 1420
  • [8] Use of a microbubble agent to increase the effects of high intensity focused ultrasound on liver tissue
    Kaneko, Y
    Maruyama, T
    Takegami, K
    Watanabe, T
    Mitsui, H
    Hanajiri, K
    Nagawa, HA
    Matsumoto, Y
    EUROPEAN RADIOLOGY, 2005, 15 (07) : 1415 - 1420
  • [9] High-intensity focused ultrasound ablation of rabbit kidney tumors
    Adams, JB
    Moore, RG
    Anderson, JH
    Strandberg, JD
    Marshall, FF
    Davoussi, LR
    JOURNAL OF ENDOUROLOGY, 1996, 10 (01) : 71 - 75
  • [10] Enhancing effects of SonoVue, a microbubble sonographic contrast agent, on high-intensity focused ultrasound ablation in rabbit livers in vivo
    Luo, Wen
    Zhou, Xiaodong
    Ren, Xiaolong
    Zheng, Minjuan
    Zhang, Jun
    He, Guangbin
    JOURNAL OF ULTRASOUND IN MEDICINE, 2007, 26 (04) : 469 - 476