Increased polyethylene wear after cementless ABG I total hip arthroplasty

被引:0
|
作者
Karl-Stefan Delank
Philipp Drees
Nicole Menzel
Torsten Hansen
Heinz Duschner
Anke Eckardt
机构
[1] University of Cologne,Department of Orthopaedic Surgery
[2] University of Mainz,Department of Orthopaedic Surgery
[3] University of Mainz,Pathological Institute
[4] University of Mainz,Institute for Applied Structure and Microanalysis
关键词
Total hip replacement; Hydroxyapatite; Polyethylene; Wear;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:509 / 516
页数:7
相关论文
共 50 条
  • [1] Increased polyethylene wear after cementless ABG I total hip arthroplasty
    Delank, Karl-Stefan
    Drees, Philipp
    Menzel, Nicole
    Hansen, Torsten
    Duschner, Heinz
    Eckardt, Anke
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2006, 126 (08) : 509 - 516
  • [2] Measurement of polyethylene wear in cementless total hip arthroplasty
    Shih, CH
    Lee, PC
    Chen, JH
    Tai, CL
    Chen, LF
    Wu, JSS
    Chang, WH
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (03): : 361 - 365
  • [3] Risk factors for accelerated polyethylene wear and osteolysis in ABG I total hip arthroplasty
    Jiri Gallo
    Vitezslav Havranek
    Jana Zapletalova
    International Orthopaedics, 2010, 34 : 19 - 26
  • [4] Risk factors for accelerated polyethylene wear and osteolysis in ABG I total hip arthroplasty
    Gallo, Jiri
    Havranek, Vitezslav
    Zapletalova, Jana
    INTERNATIONAL ORTHOPAEDICS, 2010, 34 (01) : 19 - 26
  • [5] In Vivo Measurement of Polyethylene Wear in Cementless Total Hip Arthroplasty
    Roth, A.
    Sander, K.
    Layher, F.
    Babisch, J.
    Venbrocks, R.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2010, 77 (01) : 13 - 17
  • [6] Late dislocations after cementless total hip arthroplasty resulting from polyethylene wear
    Orozco, F
    Hozack, WJ
    JOURNAL OF ARTHROPLASTY, 2000, 15 (08): : 1059 - 1063
  • [7] Thigh mass associated with polyethylene wear-induced osteolysis after cementless total hip arthroplasty
    Youn-Soo Park
    Seung-Jae Lim
    Jin-Hong Kim
    Ajay Wala
    Archives of Orthopaedic and Trauma Surgery, 2010, 130 : 1097 - 1101
  • [8] Thigh mass associated with polyethylene wear-induced osteolysis after cementless total hip arthroplasty
    Park, Youn-Soo
    Lim, Seung-Jae
    Kim, Jin-Hong
    Wala, Ajay
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2010, 130 (09) : 1097 - 1101
  • [9] The Relationship between Acetabular Osteolytic Lesion Volume and Polyethylene Wear in Cementless Total Hip Arthroplasty
    Kitamura, N.
    Hopper, R. H.
    Leung, S. B.
    Engh, C. A., Jr.
    Engh, Ch. A.
    BIOCERAMICS AND ALTERNATIVE BEARINGS IN JOINT ARTHROPLASTY, 2005, : 209 - 218
  • [10] Early polyethylene wear and osteolysis in cementless total hip arthroplasty - The influence of femoral head size and polyethylene thickness
    Lee, PC
    Shih, CH
    Chen, WJ
    Tu, YK
    Tai, CL
    JOURNAL OF ARTHROPLASTY, 1999, 14 (08): : 976 - 981