Carboxyhemoglobin predicts oxygenator performance and imminent oxygenator change in extracorporeal membrane oxygenation

被引:0
|
作者
Erlebach, Rolf [1 ]
Buhlmann, Alix [1 ]
Andermatt, Rea [1 ]
Seeliger, Benjamin [2 ]
Stahl, Klaus [3 ]
Bode, Christian [4 ]
Schuepbach, Reto [1 ]
Wendel-Garcia, Pedro David [1 ]
David, Sascha [1 ]
机构
[1] Univ Hosp Zurich, Inst Intens Care Med, Zurich, Switzerland
[2] Hannover Med Sch, Dept Resp Med, Hannover, Germany
[3] Hannover Med Sch, Dept Gastroenterol Hepatol Infect Dis & Endocrino, Hannover, Germany
[4] Univ Hosp Bonn, Dept Anesthesiol & Intens Care Med, Bonn, Germany
关键词
Hemolysis; Thrombosis; Blood gas analysis; Co-oximetry; Coagulation; Surveillance; CARBON-MONOXIDE PRODUCTION; HEMOGLOBIN; HEMOLYSIS; OXIMETRY;
D O I
10.1186/s40635-024-00626-7
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background The continuous exposure of blood to a non-biological surface during extracorporeal membrane oxygenation (ECMO) may lead to progressive thrombus formation in the oxygenator, hemolysis and consequently impaired gas exchange. In most centers oxygenator performance is monitored only on a once daily basis. Carboxyhemoglobin (COHb) is generated upon red cell lysis and is routinely measured with any co-oximetry performed to surveille gas exchange and acid-base homeostasis every couple of hours. This retrospective cohort study aims to evaluate COHb in the arterial blood gas as a novel marker of oxygenator dysfunction and its predictive value for imminent oxygenator change. Results Out of the 484 screened patients on ECMO 89, cumulatively requiring 116 oxygenator changes within 1833 patient days, including 19,692 arterial COHb measurements were analyzed. Higher COHb levels were associated with lower post-oxygenator pO2 (estimate for log(COHb): - 2.176 [95% CI - 2.927, - 1.427], p < 0.0001) and with a shorter time to oxygenator change (estimate for log(COHb): - 67.895 [95% CI - 74.209, - 61.542] hours, p < 0.0001). COHb was predictive of oxygenator change within 6 h (estimate for log(COHb): 5.027 [95% CI 1.670, 15.126], p = 0.004). Conclusion COHb correlates with oxygenator performance and can be predictive of imminent oxygenator change. Therefore, longitudinal measurements of COHb in clinical routine might be a cheap and more granular candidate for ECMO surveillance that should be further analyzed in a controlled prospective trial design.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Membrane Oxygenator for Extracorporeal Blood Oxygenation
    Ratnaningsih, Enny
    Aryanti, Putu Teta Prihartini
    Himma, Nurul Faiqotul
    Wardani, Anita Kusuma
    Khoiruddin, Khoiruddin
    Kadj, Grandprix Thomryes Marth
    Prasetya, Nicholaus
    Wenten, I. Gede
    JOURNAL OF ENGINEERING AND TECHNOLOGICAL SCIENCES, 2021, 53 (05):
  • [2] Use of Carboxyhemoglobin as an Early Sign of Oxygenator Dysfunction in Patients Supported by Extracorporeal Membrane Oxygenation
    Cousin, Vladimir L.
    Giraud, Raphael
    Assouline, Benjamin
    Silva, Ivo Neto
    Bendjelid, Karim
    FRONTIERS IN MEDICINE, 2022, 9
  • [3] OXYGENATOR IMPACT ON REMDESIVIR IN EXTRACORPOREAL MEMBRANE OXYGENATION CIRCUITS
    Cies, Jeffrey
    Moore, Wayne
    Deacon, Jillian
    Enache, Adela
    Chopra, Arun
    CRITICAL CARE MEDICINE, 2023, 51 (01) : 315 - 315
  • [4] Oxygenator impact on voriconazole in extracorporeal membrane oxygenation circuits
    Cies, Jeffrey J.
    Moore, Wayne S., II
    Giliam, Nadji
    Low, Tracy
    Marino, Daniel
    Deacon, Jillian
    Enache, Adela
    Chopra, Arun
    PERFUSION-UK, 2020, 35 (06): : 529 - 533
  • [5] OXYGENATOR IMPACT ON CEFTAROLINE IN EXTRACORPOREAL MEMBRANE OXYGENATION CIRCUITS
    Cies, Jeffrey
    Moore, Wayne
    Gilliam, Nadju
    Enache, Adela
    Chopra, Arun
    CRITICAL CARE MEDICINE, 2018, 46 (01) : 423 - 423
  • [6] The effects of propofol on extracorporeal membrane oxygenation oxygenator exchange
    Browder, Kelsey L.
    Ather, Ayesha
    Pandya, Komal A.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2021, 44 (12): : 938 - 943
  • [7] Oxygenator Impact on Ceftaroline in Extracorporeal Membrane Oxygenation Circuits
    Cies, Jeffrey J.
    Moore, Wayne S., II
    Giliam, Nadji
    Low, Tracy
    Enache, Adela
    Chopra, Arun
    PEDIATRIC CRITICAL CARE MEDICINE, 2018, 19 (11) : 1077 - 1082
  • [8] OXYGENATOR IMPACT ON VORICONAZOLE IN EXTRACORPOREAL MEMBRANE OXYGENATION CIRCUITS
    Cies, Jeffrey
    Moore, Wayne
    Gilliam, Nadju
    Low, Tracy
    Enache, Adela
    Chopra, Arun
    CRITICAL CARE MEDICINE, 2019, 47
  • [9] Predictors of membrane oxygenator failure in pediatric extracorporeal membrane oxygenation
    Ikeda, Makoto
    Murayama, Hiroomi
    Aoki, Satoshi
    Motomura, Makoto
    Kojima, Taiki
    ARTIFICIAL ORGANS, 2024, 48 (11) : 1346 - 1354
  • [10] OXYGENATOR IMPACT ON PERAMIVIR IN EXTRACORPOREAL MEMBRANE OXYGENATION CIRCUITS
    Cies, Jeffrey
    Moore, Wayne
    Marino, Daniel
    Deacon, Jillian
    Enache, Adela
    Chopra, Arun
    CRITICAL CARE MEDICINE, 2022, 50 (01) : 499 - 499