Impedance of a goat eye lens

被引:0
|
作者
K. S. Kohli
D. V. Rai
P. Kumar
V. K. Jindal
N. Goyal
机构
[1] Panjab University,Department of Biophysics
[2] Panjab University,Center of Advanced Studies in Physics
关键词
Lens; Cole-Cole plot; Complex impedance; Dielectric constant; Electrode polarisation; Dipolar model;
D O I
暂无
中图分类号
学科分类号
摘要
The complex electrical impedance of a goat eye lens is studied in the frequency range 10mHz−10Hz at room temperature, using a computer-controlled AC impedance system. AC impedance software (model 368, version 2.2) is employed to determine the total impedance and capacitance of the eye lens at various frequencies. A Cole-Cole plot of the eye lens material is drawn between the real component of impedance Z′ and the imaginary component Z″ for each excitation frequency that shows a perfect arc of a semicircle, with its centre lying below the abscissa at an angle of 35°. The half-angle ϕ between R0 and R∞ is found to be 55°, which mathematically demonstrates the selective permeability of the eye lens. Using graphical analysis of the Cole-Cole plot, characteristic frequency fc and distribution factor α are observed to be 1Hz and 0.77, respectively. At characteristic frequency, capacitance and total impedance are found to be 1.14μF and 9.08kΩ. The effect of electrode polarisation on capacitance is corrected, based on Fricke's power function. The observed electrical parameters are then used to explain the multiple current path through various tissue compartments. Further, an attempt is made to explain the results on the basis of a possible dipolar model.
引用
收藏
页码:348 / 353
页数:5
相关论文
共 50 条
  • [1] Impedance of a goat eye lens
    Kohli, KS
    Rai, DV
    Kumar, P
    Jindal, VK
    Goyal, N
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1997, 35 (04) : 348 - 353
  • [2] Impedance of a goat eye lens
    Department of Biophysics, Panjab University, Chandigraph, 160 014, India
    不详
    不详
    MED. BIOL. ENG. COMPUT., 4 (348-353):
  • [3] Impedance of goat eye lens at different DC voltages
    K. S. Kohli
    D. V. Rai
    V. K. Jindal
    N. Goyal
    Medical and Biological Engineering and Computing, 1998, 36 : 604 - 607
  • [4] Impedance of goat eye lens at different DC voltages
    Department of Biophysics, Panjab University, Chandigarh-160 014, India
    不详
    Medical and Biological Engineering and Computing, 1998, 36 (05): : 604 - 607
  • [5] Impedance of goat eye lens at different DC voltages
    Kohli, KS
    Rai, DV
    Jindal, VK
    Goyal, N
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1998, 36 (05) : 604 - 607
  • [6] INVITRO STUDIES ON THE EFFECT OF CADMIUM ON GOAT EYE LENS
    SRIVASTAVA, VK
    PANDEY, DC
    VARSHNEY, N
    CURRENT SCIENCE, 1989, 58 (12): : 712 - 713
  • [7] Electrical impedance tomography of the eye: In vitro measurements of the cornea and the lens
    Jurgens, I
    Rosell, J
    Riu, PJ
    PHYSIOLOGICAL MEASUREMENT, 1996, 17 : A187 - A195
  • [8] Goat's eye integrated with a human cataractous lens: A training model for phacoemulsification
    Sengupta, Sabyasachi
    Dhanapal, Praveen
    Nath, Manas
    Haripriya, Aravind
    Venkatesh, Rengaraj
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2015, 63 (03) : 275 - U157
  • [9] Impedance of goat lens as a function of frequency at DC voltages 0, 50, 100, 200 mV
    Rai, D. V.
    Kohli, K. S.
    ELECTROMAGNETIC BIOLOGY AND MEDICINE, 2006, 25 (03) : 155 - 162
  • [10] In vitro prevention of cataract by Oyster Mushroom Pleurotus florida extract on isolated goat eye lens
    Ganeshpurkar, Aditya
    Bhadoriya, Santosh Singh
    Pardhi, Priya
    Jain, Alok Pal
    Rai, Gopal
    INDIAN JOURNAL OF PHARMACOLOGY, 2011, 43 (06) : 667 - 670