Intravascular Ultrasound for Assessment of Residual Coarctation of the Aorta after Balloon Angioplasty in Infants

被引:0
|
作者
Hojjat Mortezaeian
Yasaman Khalili
Majid Farrokhi
Saleheh Tajalli
Akbar Shah Mohammadi
Ahmad Vesal
Fariba Alaei
Ata Firouzi
Omid Shafe
Mina Farshid Gohar
Shakeel Ahmad Qureshi
机构
[1] Iran University of Medical Sciences,Cardiovascular Intervention Research Center, Rajaie Cardiovascular Medical and Research Center
[2] Iran Medical University of Medical Sciences,Rajaie Cardiovascular Medical and Research Center
[3] Iran University of Medical Sciences,Nursing Care Research Center (NCRC), School of Nursing and Midwifery
[4] Shahid Beheshti University of Medical Sciences,Department of Pediatric Cardiology, Faculty of Medicine, Mofid Children’s Hospital
[5] Qazvin University of Medical Sciences,Children Growth Research Center, Research Institute for Prevention of Non
[6] Evelina London Children’s Hospital,Communicable Diseases
来源
Pediatric Cardiology | 2021年 / 42卷
关键词
Ultrasonography; Child; Aortic coarctation; Angiography;
D O I
暂无
中图分类号
学科分类号
摘要
Intravascular ultrasound (IVUS) has been introduced as an accurate and minimally invasive diagnostic technique for the assessment of vascular anatomy and its abnormalities. We believe that IVUS can be used for clarifying the reasons for failure of balloon angiography in infantile coarctation of the aorta (CoA), because post-balloon angioplasty tearing, intimal flap, thrombosis and pseudoaneurysm of the aorta can be evaluated by IVUS with greater sensitivity and specificity. We aimed to assess the outcome of balloon angioplasty of CoA using angiography as the gold standard and IVUS as a new method in infants, comparing the two techniques for the evaluation of the diameter and area of CoA segment pre- and post-procedure. This cross-sectional study was performed on 18 infants hospitalized with a final diagnosis of CoA. All the infants underwent angiography and were also assessed by IVUS to measure the preoperative and postoperative diameter of the narrow segment in the two anterior–posterior and lateral views. In assessment by IVUS, the mean diameter of the coarctation site increased from 2.10 ± 0.30 mm to 4.50 ± 0.94 mm (P < 0.001). Similarly, the average minimum area of the coarctation level increased from 5.26 ± 1.50 mm2 to 13.77 ± 3.48 mm2 after angioplasty (P < 0.001). Comparing these findings, angiography and IVUS showed a high level of agreement. In the assessment of a dissection flap, there was a high level of agreement between angioplasty and IVUS before the procedure, but IVUS had higher accuracy after the procedure. Our study showed that IVUS was more reliable than angiography in the assessment of residual coarctation. IVUS yielded high sensitivity (58.3%) and specificity (100%) for discriminating the presence and absence of residual coarctation as well as the need for repeating the procedure. The assessment of coarctation before and after angioplasty procedures in children is possible using the IVUS method, with high accuracy. IVUS can offer greater accuracy than angiography in the evaluation of the coarctation area, detecting tears, dissection and flaps, and assessment of residual coarctation.
引用
收藏
页码:442 / 450
页数:8
相关论文
共 50 条
  • [1] Intravascular Ultrasound for Assessment of Residual Coarctation of the Aorta after Balloon Angioplasty in Infants
    Mortezaeian, Hojjat
    Khalili, Yasaman
    Farrokhi, Majid
    Tajalli, Saleheh
    Mohammadi, Akbar Shah
    Vesal, Ahmad
    Alaei, Fariba
    Firouzi, Ata
    Shafe, Omid
    Gohar, Mina Farshid
    Qureshi, Shakeel Ahmad
    PEDIATRIC CARDIOLOGY, 2021, 42 (02) : 442 - 450
  • [2] BALLOON ANGIOPLASTY OF COARCTATION OF THE AORTA EVALUATED WITH INTRAVASCULAR ULTRASOUND IMAGING
    HARRISON, JK
    SHEIKH, KH
    DAVIDSON, CJ
    KISSLO, KB
    LEITHE, ME
    HIMMELSTEIN, SI
    KANTER, RJ
    BASHORE, TM
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) : 906 - 909
  • [3] BALLOON DILATATION ANGIOPLASTY FOR COARCTATION OF THE AORTA IN INFANTS
    EVANS, VL
    NIHILL, MR
    ALYOUSEF, S
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (02) : A46 - A46
  • [4] BALLOON ANGIOPLASTY FOR COARCTATION OF THE AORTA IN INFANTS AND CHILDREN
    DEGIOVANNI, JV
    WRIGHT, JGC
    SILOVE, ED
    BRITISH HEART JOURNAL, 1987, 57 (01): : 66 - 67
  • [5] BALLOON ANGIOPLASTY FOR COARCTATION OF THE AORTA
    RAO, PS
    PEDIATRIC RESEARCH, 1986, 20 (04) : A174 - A174
  • [6] Immediate Outcomes of Balloon Angioplasty for Coarctation of the Aorta in infants and children
    Kazmi, Tehmina
    Kazmi, Uzma
    Shah, S. Salman A.
    Hyder, Syed Najam
    Ali, Muhammad Maisam
    Asaf, Saedah
    Sadiq, Masood
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (10): : 2516 - 2518
  • [7] INTRAVASCULAR STENTING VERSUS BALLOON ANGIOPLASTY TREATMENT OF EXPERIMENTAL COARCTATION OF AORTA
    SLACK, MC
    OLAUGHLIN, MP
    GRIFKA, RG
    MATSUAKA, R
    KEARNEY, D
    CIRCULATION, 1992, 86 (04) : 42 - 42
  • [8] NO PARADOXICAL HYPERTENSION AFTER BALLOON ANGIOPLASTY OF COARCTATION OF THE AORTA
    CHOY, M
    ROCCHINI, AP
    BEEKMAN, RH
    KVESELIS, DA
    ROSENTHAL, A
    MOTT, CS
    CIRCULATION, 1985, 72 (04) : 260 - 260
  • [9] REMODELING OF THE AORTA AFTER SUCCESSFUL BALLOON COARCTATION ANGIOPLASTY
    RAO, PS
    CAREY, P
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (05) : 1312 - 1317
  • [10] Balloon Angioplasty of Native Coarctation of the Aorta in Infants and Neonates: Is It Worth the Hassle?
    H.T. Patel
    A. Madani
    Y.M. Paris
    K.G. Warner
    Z.M. Hijazi
    Pediatric Cardiology, 2001, 22 : 53 - 57