Development of animal-dedicated phased-array coils for rat images

被引:0
|
作者
Eun-Hoe Goo
Hyong-Hu Park
In-Chul Im
Jae-Seung Lee
机构
[1] Cheong-ju University,Department of Radiological Science
[2] Bong-Seng Memorial Hospital,Department of Radiology
[3] Dong-eui University,Department of Radiological Science
来源
关键词
Phased-array coil; Loop coil; Signal-to-noise ratio (SNR);
D O I
暂无
中图分类号
学科分类号
摘要
The researched aimed to achieve high-resolution images by manufacturing rat-dedicated 8-channel phased-array coils, with a receiver in every coil and with a small diameter. Recently, this has been the most widely used method in animal experiments. The manufactured rat-dedicated 8-channel phased-array coil is made of polyimide, a PC board material. The manufactured coil is an 8-channel, phased-array, receive-only coil. The coil has a diameter of 80 mm and a length of 150 mm. An overlap among channels is 8 mm. The average difference between the signal-to-noise ratios of a rat-dedicated 8-channel phased-array coil and a clinically-dedicated 1-channel loop coil was 748.93 ± 10.59, with the better SNR being observed in the rat-dedicated coil. This study verified that the manufactured phased-array coil was much better in terms of signal-to-noise ratio when the rat-dedicated 8-channel phased-array coils at 3.0-T was compared to a clinically-dedicated 1-channel loop coil. Moreover, further use of rat-dedicated coils in animal experiments to acquire various signals from organs other than just the brain is expected in the future.
引用
收藏
页码:815 / 820
页数:5
相关论文
共 50 条
  • [1] Development of animal-dedicated phased-array coils for rat images
    Goo, Eun-Hoe
    Park, Hyong-Hu
    Im, In-Chul
    Lee, Jae-Seung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 61 (05) : 815 - 820
  • [2] PHASED-ARRAY COILS FOR UPPER EXTREMITY MRA
    MONROE, JW
    SCHMALBROCK, P
    SPIGOS, DG
    MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (02) : 224 - 229
  • [3] Impact of different phased-array coils on the quality of prostate magnetic resonance images
    Stocker, Daniel
    Manoliu, Andrei
    Becker, Anton S.
    Barth, Borna K.
    Nanz, Daniel
    Klarhoefer, Markus
    Donati, Olivio F.
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2021, 8
  • [4] Mouse MRI using phased-array coils
    Gareis, Daniel
    Wichmann, Tobias
    Lanz, Titus
    MeIkus, Gerd
    Horn, Michael
    Jakob, Peter M.
    NMR IN BIOMEDICINE, 2007, 20 (03) : 326 - 334
  • [5] Dedicated phased-array coil for peripheral MRA
    R. Janka
    F. Fellner
    C. Fellner
    M. Requardt
    A. Reykowski
    W. Lang
    W. Bautz
    European Radiology, 2000, 10 : 1745 - 1749
  • [6] Dedicated phased-array coil for peripheral MRA
    Janka, R
    Fellner, F
    Fellner, C
    Requardt, M
    Reykowski, A
    Lang, W
    Bautz, W
    EUROPEAN RADIOLOGY, 2000, 10 (11) : 1745 - 1749
  • [7] Design and Development of Phased-Array Coils for 1.5T MRI Scanner
    Morey, Abhay M.
    Bhujade, Sheetal
    Bhuiya, Tapas
    Thakur, Samruddha
    Pandey, Twisha
    PROCEEDINGS OF IEEE INTERNATIONAL CONFERENCE ON TECHNOLOGICAL ADVANCEMENTS IN POWER AND ENERGY, 2015, : 165 - 169
  • [8] Phased-array development at DARPA
    Corey, L
    Jaska, E
    Guerci, J
    IEEE INTERNATIONAL SYMPOSIUM ON PHASED ARRAY SYSTEMS AND TECHNOLOGY 2003, 2003, : 9 - 16
  • [9] CARCINOMA OF THE PROSTATE-GLAND - MR-IMAGING WITH PELVIC PHASED-ARRAY COILS VERSUS INTEGRATED ENDORECTAL PELVIC PHASED-ARRAY COILS
    HRICAK, H
    WHITE, S
    VIGNERON, D
    KURHANEWICZ, J
    KOSCO, A
    LEVIN, D
    WEISS, J
    NARAYAN, P
    CARROLL, PR
    RADIOLOGY, 1994, 193 (03) : 703 - 709
  • [10] TRENDS IN PHASED-ARRAY DEVELOPMENT
    SCHELL, AC
    MICROWAVE JOURNAL, 1986, 29 (03) : 26 - &