Application of cyanide hydrolase from Klebsiella sp. in a biosensor system for the detection of low-level cyanide

被引:0
|
作者
Karen K. W. Mak
Alex W. C. Law
Shinsuke Tokuda
Hideshi Yanase
Reinhard Renneberg
机构
[1] The Hong Kong University of Science and Technology,Biosensors and Bioelectronics Laboratory, Department of Chemistry
[2] Tottori University,Department of Biotechnology
来源
关键词
Cyanide; Sodium Salicylate; Enzyme Electrode; Potassium Cyanide; Cyanide Hydratase;
D O I
暂无
中图分类号
学科分类号
摘要
A partially purified preparation of cyanide hydrolase (cyanidase) from a bacterium, Klebsiella sp., was applied as a biocatalyst in a biosensor system for low-level cyanide detection. In the biosensor system cyanide hydrolase converts cyanide into formate and ammonia. The formate produced in the cyanide degradation was detected with a formate biosensor, in which formate dehydrogenase (FDH; E.C. 1.2.1.2) was co-immobilized with salicylate hydroxylase (SHL; E.C. 1.14.13.1) on a Clark electrode. The principle of the formate sensor is that FDH converts formate into carbon dioxide using β-nicotinamide adenine dinucleotide hydrate (NAD+). The corresponding NADH produced is then oxidized to NAD+ by SHL using salicylate and oxygen. The oxygen consumption is monitored with the Clark electrode. The optimum buffer pH and temperature for the enzymatic hydrolysis of potassium cyanide were studied. The preliminary experiments including the pretreatment of cyanide with cyanide hydrolase and then detection by the formate sensor gave a detection limit at 7.3 μmol l−1 cyanide. The linear range of the calibration curve was between 30 μmol l−1 and 300 μmol l−1 cyanide.
引用
收藏
页码:631 / 636
页数:5
相关论文
共 50 条
  • [1] Application of cyanide hydrolase from Klebsiella sp in a biosensor system for the detection of low-level cyanide
    Mak, KKW
    Law, AWC
    Tokuda, S
    Yanase, H
    Renneberg, R
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2005, 67 (05) : 631 - 636
  • [2] Chronic Low-Level Cyanide Intoxication in an Electroplating Plant in Taiwan
    Fan, Hao-Yi
    Luo, Jiin-Chyuan John
    Yeh, Wei-Chung
    Tsao, Yu-Chung
    Huang, Pai-Tsang
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2022, 64 (09) : 777 - 781
  • [3] EXHALED HYDROGEN CYANIDE IS NOT AFFECTED BY LOW-LEVEL VARIATION IN ATMOSPHERIC CONCENTRATION
    Sturney, S.
    Storer, M.
    Dummer, J.
    Cook, J.
    Epton, M.
    RESPIROLOGY, 2012, 17 : 58 - 58
  • [4] Construction of a Nano Biosensor for Cyanide Anion Detection and Its Application in Environmental and Biological Systems
    Dong, Zhen-Zhen
    Yang, Chao
    Vellaisamy, Kasipandi
    Li, Guodong
    Leung, Chung-Hang
    Ma, Dik-Lung
    ACS SENSORS, 2017, 2 (10): : 1517 - 1522
  • [5] A LOW-LEVEL RADON DETECTION SYSTEM
    SRIVASTAVA, GK
    RAGHAVAYYA, M
    KHAN, AH
    KOTRAPPA, P
    HEALTH PHYSICS, 1984, 46 (01): : 225 - 228
  • [6] Solubilization of Radionuclides with Bacillus sp. in Low-level Contaminated Soil
    Liu, Li
    Yuan, Shi-bin
    Li, Yang-ping
    2015 4TH INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENTAL PROTECTION (ICEEP 2015), 2015, : 606 - 612
  • [7] LOW-LEVEL LOW-FREQUENCY DETECTION SYSTEM
    LARSEN, NT
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1962, 33 (11): : 1200 - &
  • [8] Highly sensitive detection of low-level water content in organic solvents and cyanide in aqueous media using novel solvatochromic AIEE fluorophores
    Chen, Wei
    Zhang, Zhiyun
    Li, Xin
    Agren, Hans
    Su, Jianhua
    RSC ADVANCES, 2015, 5 (16) : 12191 - 12201
  • [9] Nanomolar Level Fluorogenic Detection of Cyanide with an Amide Functionalized Zirconium Metal-Organic Framework and Its Application in Real-World Cyanide Monitoring
    Ghosh, Subhrajyoti
    Nagarjun, Nagarathinam
    Alam, Masud
    Dhakshinamoorthy, Amarajothi
    Biswas, Shyam
    EUROPEAN JOURNAL OF INORGANIC CHEMISTRY, 2022, 2022 (18)
  • [10] DETECTION OF LOW-LEVEL CHEMI-LUMINESCENCE AND ITS APPLICATION FOR THE ASSAY SYSTEM OF LIPID HYDROPEROXIDES
    MIYAZAWA, T
    NIPPON NOGEIKAGAKU KAISHI-JOURNAL OF THE JAPAN SOCIETY FOR BIOSCIENCE BIOTECHNOLOGY AND AGROCHEMISTRY, 1989, 63 (02): : 159 - 166