Modeling Blood Flow Circulation in Intracranial Arterial Networks: A Comparative 3D/1D Simulation Study

被引:0
|
作者
L. Grinberg
E. Cheever
T. Anor
J. R. Madsen
G. E. Karniadakis
机构
[1] Brown University,Division of Applied Mathematics
[2] Harvard Medical School,Children’s Hospital
来源
关键词
Computational fluid dynamics (CFD); Circle of Willis; Cerebral blood flow;
D O I
暂无
中图分类号
学科分类号
摘要
We compare results from numerical simulations of pulsatile blood flow in two patient-specific intracranial arterial networks using one-dimensional (1D) and three-dimensional (3D) models. Specifically, we focus on the pressure and flowrate distribution at different segments of the network computed by the two models. Results obtained with 1D and 3D models with rigid walls show good agreement in massflow distribution at tens of arterial junctions and also in pressure drop along the arteries. The 3D simulations with the rigid walls predict higher amplitude of the flowrate and pressure temporal oscillations than the 1D simulations with compliant walls at various segments even for small time-variations in the arterial cross-sectional areas. Sensitivity of the flow and pressure with respect to variation in the elasticity parameters is investigated with the 1D model.
引用
收藏
页码:297 / 309
页数:12
相关论文
共 50 条
  • [1] Modeling Blood Flow Circulation in Intracranial Arterial Networks: A Comparative 3D/1D Simulation Study
    Grinberg, L.
    Cheever, E.
    Anor, T.
    Madsen, J. R.
    Karniadakis, G. E.
    ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (01) : 297 - 309
  • [2] A comparative study of flow induced by 1D, 2D and 3D ultrasounds
    WU WenHua
    ZHAI Wei
    ZHANG Yi Bao
    XI HengDong
    LIU HaiMan
    ZHANG Jian
    WEI BingBo
    Science China(Technological Sciences), 2019, 62 (07) : 1224 - 1231
  • [3] A comparative study of flow induced by 1D, 2D and 3D ultrasounds
    Wu, WenHua
    Zhai, Wei
    Zhang, YiBao
    Xi, HengDong
    Liu, HaiMan
    Zhang, Jian
    Wei, BingBo
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2019, 62 (07) : 1224 - 1231
  • [4] A comparative study of flow induced by 1D, 2D and 3D ultrasounds
    WenHua Wu
    Wei Zhai
    YiBao Zhang
    HengDong Xi
    HaiMan Liu
    Jian Zhang
    BingBo Wei
    Science China Technological Sciences, 2019, 62 : 1224 - 1231
  • [5] A comparative study of flow induced by 1D, 2D and 3D ultrasounds
    WU WenHua
    ZHAI Wei
    ZHANG Yi Bao
    XI HengDong
    LIU HaiMan
    ZHANG Jian
    WEI BingBo
    Science China(Technological Sciences), 2019, (07) : 1224 - 1231
  • [6] Coupling strategies for the numerical simulation of blood flow in deformable arteries by 3D and 1D models
    Nobile, F.
    MATHEMATICAL AND COMPUTER MODELLING, 2009, 49 (11-12) : 2152 - 2160
  • [7] 3D Open Channel Flow Modeling by Applying 1D Adjustment
    Abedini, A. A.
    Ghiassi, R.
    Ardestani, M.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH, 2011, 5 (02) : 381 - 394
  • [8] Performance of Broken Particulate Filters—a 1D and 3D Simulation Study
    T. Chittipotula
    S. Kutschi
    J. C. Wurzenberger
    Emission Control Science and Technology, 2020, 6 : 186 - 194
  • [9] A 1D Model of the Arterial Circulation in Mice
    Aslanidou, Lydia
    Trachet, Bram
    Reymond, Philippe
    Fraga-Silva, Rodrigo A.
    Segers, Patrick
    Stergiopulos, Nikolaos
    ALTEX-ALTERNATIVES TO ANIMAL EXPERIMENTATION, 2016, 33 (01) : 13 - 28
  • [10] A Comparative Study of 3D and 1D Acoustic Simulations of the Higher Frequencies of Speech
    Blandin, Remi
    Stone, Simon
    Remacle, Angelique
    Didone, Vincent
    Birkholz, Peter
    IEEE-ACM TRANSACTIONS ON AUDIO SPEECH AND LANGUAGE PROCESSING, 2023, 31 : 3837 - 3847