A possibility of parallel and anti-parallel diffraction measurements on neutron diffractometer employing bent perfect crystal monochromator at the monochromatic focusing condition

被引:0
|
作者
Yong Nam Choi
Shin Ae Kim
Sung Kyu Kim
Sung Baek Kim
Chang-Hee Lee
Pavel Mikula
机构
[1] Korea Atomic Energy Research Institute,HANARO Center
[2] Nuclear Physics Institute,undefined
来源
Pramana | 2004年 / 63卷
关键词
Neutron diffractometer; bent crystal monochromator; monochromatic focusing; 28.41.Rc;
D O I
暂无
中图分类号
学科分类号
摘要
In a conventional diffractometer having single monochromator, only one position, parallel position, is used for the diffraction experiment (i.e. detection) because the resolution property of the other one, anti-parallel position, is very poor. However, a bent perfect crystal (BPC) monochromator at monochromatic focusing condition can provide a quite flat and equal resolution property at both parallel and anti-parallel positions and thus one can have a chance to use both sides for the diffraction experiment. From the data of the FWHM and the Δd/d measured on three diffraction geometries (symmetric, asymmetric compression and asymmetric expansion), we can conclude that the simultaneous diffraction measurement in both parallel and anti-parallel positions can be achieved.
引用
收藏
页码:175 / 181
页数:6
相关论文
共 5 条
  • [1] A possibility of parallel and anti-parallel diffraction measurements on neutron diffractometer employing bent perfect crystal monochromator at the monochromatic focusing condition
    Choi, YN
    Kim, SA
    Kim, SK
    Kim, SB
    Lee, CH
    Mikula, P
    PRAMANA-JOURNAL OF PHYSICS, 2004, 63 (01): : 175 - 181
  • [2] Bent perfect crystal monochromator at the monochromatic focusing condition
    Choi, Y. N.
    Kim, S. A.
    Kim, S. K.
    Kim, S. B.
    Lee, C. H.
    Mikula, P.
    Vrana, M.
    ZEITSCHRIFT FUR KRISTALLOGRAPHIE, 2006, : 199 - 204
  • [3] USE OF A BENT PACKET OF PERFECT CRYSTAL LAMELLAE AS FOCUSING NEUTRON MONOCHROMATOR
    FREY, F
    NUCLEAR INSTRUMENTS & METHODS, 1975, 125 (01): : 9 - 17
  • [4] Focusing bent perfect-crystal neutron monochromator - A key to high-resolution stress/strain measurement studies of polycrystalline materials
    Ono, M
    Mikula, P
    Harjo, S
    Saroun, J
    Yoneda, K
    Sawano, J
    Sakurai, Y
    Kobayashi, T
    EUROPEAN POWDER DIFFRACTION, PTS 1 AND 2, 2000, 321-3 : 296 - 301
  • [5] Single and multiple diffraction in non-absorbing perfect crystal spheres bathed in the monochromatic parallel incident beam:: The intensity pattern of ψ-scans calculated in the framework of the kinematical approach
    Rossmanith, E