Technique for Measuring Limb Occlusion Pressure that Facilitates Personalized Tourniquet Systems: A Randomized Trial

被引:0
|
作者
Bassam A. Masri
Brian Day
Alastair S. E. Younger
Jeswin Jeyasurya
机构
[1] University of British Columbia,Department of Orthopaedics
[2] University of British Columbia,Department of Orthopaedics
[3] Western Clinical Engineering,undefined
关键词
Tourniquet; Limb occlusion pressure; Personalized; Tourniquet safety; Tourniquet injury;
D O I
暂无
中图分类号
学科分类号
摘要
We developed a technique for measuring patient limb occlusion pressure (LOP) through a tourniquet cuff that overcomes many limitations of existing LOP measurement techniques. The purpose of the study is to determine whether the LOP measured by the proposed technique is statistically or clinically different from that measured by the gold standard Doppler ultrasound technique. The study used randomized crossover multicenter trials. 143 pre- and post-surgical patients with a mean age of 54 years (range 17–86 years) were enrolled in the study. Pneumatic cuffs were applied to the non-operative upper and lower limbs and LOP was measured using the proposed technique and the Doppler ultrasound technique. From a total of 252 usable measurements for each technique (134 for upper limbs and 118 for lower limbs), the mean difference in LOP between the two techniques was 1 ± 8 mmHg for the upper limbs, 0 ± 15 mmHg for the lower limbs, and 1 ± 12 mmHg overall. The differences between the proposed technique and the Doppler technique were neither statistically nor clinically significant. The simplicity, effectiveness, and accuracy of the proposed technique should lead to broader clinical usage and acceptance of LOP measurement, thus leading to safer, personalized pressures in surgical tourniquet applications.
引用
收藏
页码:644 / 650
页数:6
相关论文
共 50 条
  • [1] Technique for Measuring Limb Occlusion Pressure that Facilitates Personalized Tourniquet Systems: A Randomized Trial
    Masri, Bassam A.
    Day, Brian
    Younger, Alastair S. E.
    Jeyasurya, Jeswin
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2016, 36 (05) : 644 - 650
  • [2] Development of Personalized Tourniquet Systems Using a New Technique for Measuring Limb Occlusion Pressure
    McEwen, J. A.
    Masri, B. A.
    Day, B.
    Younger, A. S.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 1325 - 1328
  • [3] Limb Occlusion Pressure Versus Standard Pneumatic Tourniquet Pressure in Open Carpal Tunnel Surgery - A Randomized Trial
    Morehouse, Hannah
    Goble, Haley M.
    Lambert, Bradley S.
    Cole, Jaclyn
    Holderread, Brendan M.
    Le, Jessica T.
    Siff, Todd
    McCulloch, Patrick C.
    Liberman, Shari R.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (12)
  • [4] Limb occlusion pressure versus standard tourniquet inflation pressure in minor hand surgery: a randomized controlled trial
    Kanchanathepsak, Thepparat
    Pukrittayakamee, Natsuda Chua
    Woratanarat, Patarawan
    Tawonsawatruk, Tulyapruek
    Angsanuntsukh, Chanika
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [5] Limb occlusion pressure versus standard tourniquet inflation pressure in minor hand surgery: a randomized controlled trial
    Thepparat Kanchanathepsak
    Natsuda Chua Pukrittayakamee
    Patarawan Woratanarat
    Tulyapruek Tawonsawatruk
    Chanika Angsanuntsukh
    Journal of Orthopaedic Surgery and Research, 18
  • [6] Tourniquet pressure settings based on limb occlusion pressure determination or arterial occlusion pressure estimation in total knee arthroplasty? A prospective, randomized, double blind trial
    Tuncali, Bahattin
    Boya, Hakan
    Kayhan, Zeynep
    Arac, Sukru
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2018, 52 (04) : 256 - 260
  • [7] Personalized tourniquet pressure versus uniform tourniquet pressure in trauma orthopedic surgery of extremities: a prospective randomized controlled study
    Tan, Zhelun
    Sun, Zhijian
    Muertizha, Mieralimu
    Jue, Hou
    Wang, Zongrui
    Chen, Chenghui
    Wu, Xinbao
    Ting, Li
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):
  • [8] Personalized tourniquet pressure versus uniform tourniquet pressure in orthopedic trauma surgery of extremities: A prospective randomized controlled study protocol
    Sun, Zhi-jian
    Chen, Cheng-hui
    Tan, Zhe-lun
    Li, Chang-run
    Fei, Han
    Yu, Xiang
    Yao, Dong-chen
    Li, Ting
    CONTEMPORARY CLINICAL TRIALS COMMUNICATIONS, 2024, 42
  • [9] Efficacy of arterial occlusion pressure estimation-based tourniquet pressure settings in upper limb surgery
    Tuncali, B.
    Kokten, G.
    Boya, H.
    Altinel, F.
    Kayhan, Z.
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2022, 27 (05) : 1051 - 1055
  • [10] MEASURING LIMB OCCLUSION PRESSURE USING DIFFERENT VASCULAR DOPPLERS
    Barrett, Kiara B.
    Page, Logan B.
    Szczyglowski, Marcin K.
    Martin, Tyler D.
    Mouser, J. Grant
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2020, 52 (07) : 889 - 889