Whispering gallery mode biosensors in the low-Q limit

被引:0
|
作者
A. Weller
F.C. Liu
R. Dahint
M. Himmelhaus
机构
[1] Universität Heidelberg,Angewandte Physikalische Chemie
来源
Applied Physics B | 2008年 / 90卷
关键词
Transverse Magnetic; Transverse Electric; Whisper Gallery Mode; Bovine Serum Albu; High Mass Sensitivity;
D O I
暂无
中图分类号
学科分类号
摘要
Whispering gallery modes (WGM) of dye-doped polystyrene beads with diameters from 20 down to 1.5 μm are studied with respect to their appearance and linewidth by excitation of the entire mode spectrum within the emission range of the dye. The lowest order (q=1) modes, which travel most closely to the inner particle surface, are assigned to their individual quantum numbers by means of a least-square-fit, resulting in a precise determination of particle radius and eccentricity. On this basis, the suitability of these microscopic cavities for applications in optical (bio-)sensing is explored. Due to the low quality (Q) factors of these small cavities, particles with diameters below 6 μm exhibit only q=1 modes, thereby causing a drastic simplification of the WGM spectrum. In such spectra, the shift in the WGM positions upon molecular adsorption can be easily monitored, as we demonstrate for the adsorption of bovine serum albumin as well as multiple layers of polyelectrolytes onto the surface of particles with 2 μm diameter. Mie simulations are used to confirm our findings. With a mass sensitivity limit of 3 fg, these microscopic sensors are highly competitive in the field of label-free detection techniques. Moreover, their small size and the simplified, dye-mediated excitation and detection scheme may pave the way to remote in-vitro biosensing in the future.
引用
收藏
页码:561 / 567
页数:6
相关论文
共 50 条
  • [1] Whispering gallery mode biosensors in the low-Q limit
    Weller, A.
    Liu, F. C.
    Dahint, R.
    Himmelhaus, M.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2008, 90 (3-4): : 561 - 567
  • [2] Low-Q whispering gallery modes in anisotropic metamaterial shells
    Diaz-Rubio, Ana
    Carbonell, Jorge
    Torrent, Daniel
    Sanchez-Dehesa, Jose
    PHYSICAL REVIEW B, 2013, 88 (11):
  • [3] Broadband light management using low-Q whispering gallery modes in spherical nanoshells
    Yan Yao
    Jie Yao
    Vijay Kris Narasimhan
    Zhichao Ruan
    Chong Xie
    Shanhui Fan
    Yi Cui
    Nature Communications, 3
  • [4] Broadband light management using low-Q whispering gallery modes in spherical nanoshells
    Yao, Yan
    Yao, Jie
    Narasimhan, Vijay Kris
    Ruan, Zhichao
    Xie, Chong
    Fan, Shanhui
    Cui, Yi
    NATURE COMMUNICATIONS, 2012, 3
  • [5] Interferometric detection of mode splitting for whispering gallery mode biosensors
    Knittel, Joachim
    McRae, Terry G.
    Lee, Kwan H.
    Bowen, Warwick P.
    APPLIED PHYSICS LETTERS, 2010, 97 (12)
  • [6] Whispering gallery mode biosensors using semiconductor quantum dots
    Meissner, KE
    Allen, A
    2005 IEEE SENSORS, VOLS 1 AND 2, 2005, : 4 - 7
  • [7] Sensitivity optimization in whispering gallery mode optical cylindrical biosensors
    Khozeymeh, F.
    Razaghi, M.
    8TH YOUNG RESEARCHER MEETING, 2017, 2018, 956
  • [8] The physics of extreme sensitivity in whispering gallery mode optical biosensors
    Lopez-Yglesias, Xerxes
    Gamba, Jason M.
    Flagan, Richard C.
    JOURNAL OF APPLIED PHYSICS, 2012, 111 (08)
  • [9] Flow-enhanced transient response in whispering gallery mode biosensors
    Gamba, Jason M.
    Flagan, Richard C.
    APPLIED PHYSICS LETTERS, 2011, 99 (25)
  • [10] Free space whispering gallery mode microlasers as highly sensitive biosensors
    Ferretti, Stefano
    Capocefalo, Angela
    Ceraolo, Maria Grazia
    Gentilini, Silvia
    Barolo, Lorenzo
    Baiocco, Paola
    Conti, Claudio
    Cortese, Barbara
    Bearzi, Claudia
    Rizzi, Roberto
    Ghofraniha, Neda
    EOS ANNUAL MEETING, EOSAM 2024, 2024, 309