The Use of a Milli-whistle as a Detector in Gas Analysis by Gas Chromatography

被引:0
|
作者
Cheng-Huang Lin
Yi-San He
Chien-Hung Lin
Gang-Ting Fan
Hsin-Kai Chen
机构
[1] National Taiwan Normal University,Department of Chemistry
来源
Analytical Sciences | 2014年 / 30卷
关键词
Whistle; gas chromatography; microphone; accelerometer;
D O I
暂无
中图分类号
学科分类号
摘要
This mini-review introduces a general understanding of the use of a milli-whistle as a gas chromatography (GC) detector in gas analysis, including our research on the methodology and theory associated with a number of different related applications. The milli-whistle is connected to the outlet of a GC capillary, and when the eluted gases and the GC carrier gas pass through it, a sound with a fundamental frequency is produced. The sound wave can be picked up by a microphone or an accelerometer, and after a fast Fourier transform, the online data obtained for frequency-change vs. retention time constitute a new method for detecting gases. The first part of this review discusses the fundamentals of the milli-whistle. Some modifications are also discussed, including various types of whistles and an attempt to maximize the sensitivity and stability of the method. The second part then focuses on several practical applications, including an analysis of hydrogen released from ammonia borane, inorganic gases produced from fireworks, the CO2/O2 ratio from expired human breath and a purity test for alcohols. These studies show that the GC-whistle method has great potential for use as a fast sampling ionization method, and for the direct analysis of biological and chemical samples at under ambient conditions.
引用
收藏
页码:183 / 191
页数:8
相关论文
共 50 条
  • [1] The Use of a Milli-whistle as a Detector in Gas Analysis by Gas Chromatography
    Lin, Cheng-Huang
    He, Yi-San
    Lin, Chien-Hung
    Fan, Gang-Ting
    Chen, Hsin-Kai
    ANALYTICAL SCIENCES, 2014, 30 (01) : 183 - 191
  • [2] Development and Application of a Milli-Whistle for Use in Gas Chromatography Detection
    Lin, Cheng-Huang
    Lin, Chien-Hung
    Li, Yi-Shiuan
    He, Yi-San
    ANALYTICAL CHEMISTRY, 2010, 82 (17) : 7467 - 7471
  • [3] The Use of a Gas Chromatography/Milli-whistle Technique for the On-line Monitoring of Ethanol Production Using Microtube Array Membrane Immobilized Yeast Cells
    Ming-Ju Wu
    Guan-Fu Ye
    Ching-Hao Wang
    Hong-Ting Victor Lin
    Chien-Chung Chen
    Cheng-Huang Lin
    Analytical Sciences, 2017, 33 : 625 - 630
  • [4] The Use of a Gas Chromatography/Milli-whistle Technique for the On-line Monitoring of Ethanol Production Using Microtube Array Membrane Immobilized Yeast Cells
    Wu, Ming-Ju
    Ye, Guan-Fu
    Wang, Ching-Hao
    Lin, Hong-Ting Victor
    Chen, Chien-Chung
    Lin, Cheng-Huang
    ANALYTICAL SCIENCES, 2017, 33 (05) : 625 - 630
  • [5] USE OF AN ELECTRODELESS DISCHARGE AS A DETECTOR IN GAS CHROMATOGRAPHY
    ARNIKAR, HJ
    RAO, TS
    KARMARKA.KH
    JOURNAL OF CHROMATOGRAPHY, 1967, 26 (01): : 30 - &
  • [6] USE OF HERSCH CELL AS DETECTOR IN GAS CHROMATOGRAPHY
    PHILLIPS, TR
    JOHNSON, EG
    WOODWARD, H
    ANALYTICAL CHEMISTRY, 1964, 36 (03) : 450 - &
  • [7] Non-invasive and Time-dependent Blood-sugar Monitoring via Breath-derived CO2 Correlation Using Gas Chromatograph with a Milli-whistle Gas Analyzer
    Lin, Cheng-Huang
    Wu, Luo-Xian
    Chen, Kuan-Hao
    Lo, Hsu-Feng
    Lin, King-Chuen
    Kasai, Toshio
    Chen, Chien-Chung
    Shih, Chung-Hung
    Manzano, Maria Carla
    Santos, Gil Nonato
    Manzano, Enrique
    Yu, Derrick Ethelbhert
    ANALYTICAL SCIENCES, 2020, 36 (06) : 739 - 743
  • [8] Non-invasive and Time-dependent Blood-sugar Monitoring via Breath-derived CO2 Correlation Using Gas Chromatograph with a Milli-whistle Gas Analyzer
    Cheng-Huang Lin
    Luo-Xian Wu
    Kuan-Hao Chen
    Hsu-Feng Lo
    King-Chuen Lin
    Toshio Kasai
    Chien-Chung Chen
    Chung-Hung Shih
    Maria Carla Manzano
    Gil Nonato Santos
    Enrique Manzano
    Derrick Ethelbhert Yu
    Analytical Sciences, 2020, 36 : 739 - 743
  • [9] USE OF A CONVENTIONAL MASS SPECTROMETER AS A DETECTOR FOR GAS CHROMATOGRAPHY
    LINDEMAN, LP
    ANNIS, JL
    ANALYTICAL CHEMISTRY, 1960, 32 (13) : 1742 - 1749
  • [10] THE USE OF A CARBON MONOXIDE FLAME DETECTOR IN GAS CHROMATOGRAPHY
    BADDIEL, CB
    CULLIS, CF
    CHEMISTRY & INDUSTRY, 1960, (37) : 1154 - 1155