The value of gallium-67 and thallium-201 whole-body and single-photon emission tomography images in dialysis-related β2-microglobulin amyloid

被引:0
|
作者
Tzu-Chen Yen
Kai-Yuan Tzen
Kuo-Su Chen
Chi-Juen Tsai
机构
[1] Department of Nuclear Medicine,
[2] Chang Gung Memorial Hospital,undefined
[3] Taipei Medical Center and School of Medicine,undefined
[4] Chang Gung University,undefined
[5] Taiwan,undefined
[6] Department of Nephrology,undefined
[7] Chang Gung Memorial Hospital at Keelung,undefined
[8] Taiwan,undefined
来源
关键词
Uptake Pattern; Diphosphonate; 201Tl Uptake; Emission Tomography Image; Methylene Diphosphonate;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study was to investigate the value of gallium-67 and thallium-201 whole-body and single-photon emission tomography (SPET) images in long-term dialysis patients in whom dialysis-related β2-microglobulin amyloid (β2-MA) was clinically suspected. Twenty-three patients who had received dialysis for at least 10 years were included in the study. A technetium-99m methylene diphosphonate (MDP) whole-body scan was performed in all of the patients. If there was any MDP accumulation in the articular and/or peri-articular region, 67Ga and 201Tl whole-body and SPET images were then acquired. If any 67Ga and/or 201Tl uptake was observed, a CT-guided biopsy was done. In those patients who had articular and/or peri-articular uptake of 99mTc MDP, 67Ga and/or 201Tl and who were pathologically proven to have β2-MA, 99mTc MDP, 67Ga and 201Tl whole-body scans and SPET were carried out again, both 3 months and 1 year after initiation of treatment. This served to evaluate the therapeutic effect and allowed comparison with the clinical findings. Of the 23 patients, eight had abnormal 99mTc MDP uptake. Among these eight, six had intense 99mTc MDP, 67Ga and 201Tl uptake in the articular and peri-articular regions before medication. Three months after the start of treatment, there were very marked decreases in uptake on both the 67Ga and 201Tl scans but less obvious changes in uptake of 99mTc-MDP. In comparison with the other clinical manifestations such as limitation in range of motion, the more the painful disability improved, the less was the uptake on both 67Ga and 201Tl scans. There were virtually no differences in uptake pattern between the three scans of each radiopharmaceutical obtained for each patient in both 3 months and 1 year after initial of treatment. It is concluded that 99mTc-MDP whole-body bone scan can both detect active and pre-existing inactive deposits of β2-MA. 67Ga and 201Tl scans are helpful to differentiate active from inactive deposits of β2-MA and to evaluate the therapeutic effect on these patients. SPET images are usually needed to distinguish articular and peri-articular lesions from bone lesions.
引用
收藏
页码:56 / 61
页数:5
相关论文
共 18 条
  • [1] The value of gallium-67 and thallium-201 whole-body and single-photon emission tomography images in dialysis-related β2-microglobulin amyloid
    Yen, TC
    Tzen, KY
    Chen, KS
    Tsai, CJ
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2000, 27 (01) : 56 - 61
  • [2] The value of quantitative gallium-67 single-photon emission tomography in the clinical management of malignant external otitis
    Department of Nuclear Medicine and Diagnostic Radiology, Leiden University Hospital, Netherlands
    不详
    不详
    Eur. J. Nucl. Med. Mol. Imaging, 11 (1429-1432):
  • [3] The value of quantitative gallium-67 single-photon emission tomography in the clinical management of malignant external otitis
    M. P. M. Stokkel
    R. P. Takes
    B. L. F. van Eck-Smit
    R. J. Baatenburg de Jong
    European Journal of Nuclear Medicine, 1997, 24 : 1429 - 1432
  • [4] The value of quantitative gallium-67 single-photon emission tomography in the clinical management of malignant external otitis
    Stokkel, MPM
    Takes, RP
    vanEckSmit, BLF
    deJong, RJB
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (11) : 1429 - 1432
  • [5] Diagnostic and prognostic value of dobutamine thallium-201 single-photon emission computed tomography after heart transplantation
    Wu, YW
    Yen, RF
    Lee, CM
    Ho, YL
    Chou, NK
    Wang, SS
    Huang, PJ
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2005, 24 (05): : 544 - 550
  • [6] Prognostic value of ECG-gated thallium-201 single-photon emission tomography in patients with coronary artery disease
    Matsuo, S
    Matsumoto, T
    Nakae, I
    Koh, T
    Masuda, D
    Takada, M
    Murata, K
    Horie, M
    ANNALS OF NUCLEAR MEDICINE, 2004, 18 (07) : 617 - 622
  • [7] Prognostic value of ECG-gated thallium-201 single-photon emission tomography in patients with coronary artery disease
    Shinro Matsuo
    Tetsuya Matsumoto
    Ichiro Nakae
    Terue Koh
    Daisuke Masuda
    Masahiko Takada
    Kiyoshi Murata
    Minoru Horie
    Annals of Nuclear Medicine, 2004, 18 : 617 - 622
  • [8] Reduced value of thallium-201 single-photon emission computed tomography in the management of HIV-related focal brain lesions in the era of highly active antiretroviral therapy
    Giancola, ML
    Rizzi, EB
    Schiavo, R
    Lorenzini, P
    Schininà, V
    Alba, L
    Del Grosso, B
    Gigli, B
    Rosati, S
    Mango, L
    Bibbolino, C
    Antinori, A
    AIDS RESEARCH AND HUMAN RETROVIRUSES, 2004, 20 (06) : 584 - 588
  • [9] Clinical value of 64-slice multidetector computed tomography for the detection of coronary artery stenosis: Comparison with stress thallium-201 single-photon emission computed tomography
    Sato, Akira
    Nozato, Toshihiro
    Hikita, Hiroyuki
    Ohigashi, Hirokazu
    Itou, Yusuke
    Yokoyama, Yasuhiro
    Takahashi, Atsushi
    Hiroe, Michiaki
    CIRCULATION, 2006, 114 (18) : 385 - 386
  • [10] Accuracy of a whole-body single-photon emission computed tomography with a thallium-bromide detector: Verification via Monte Carlo simulations
    Ito, Toshimune
    Hitomi, Keitaro
    Ljungberg, Michael
    Kawasaki, Sousei
    Katayama, Yuka
    Kato, Akane
    Tsuchikame, Hirotatsu
    Suzuki, Kentaro
    Miyazaki, Kyosuke
    Mogi, Ritsushi
    MEDICAL PHYSICS, 2025,