Growth and fabrication method of CdTe and its performance as a radiation detector

被引:0
|
作者
Hyojeong Choi
Manhee Jeong
Han Soo Kim
Young Soo Kim
Jang Ho Ha
Jong-Seo Chai
机构
[1] Korea Atomic Energy Research Institute,Advanced Radiation Detection Instrument & Sensor Lab
[2] Sungkyunkwan University,WCU Department of Energy Science
[3] Korea Atomic Energy Research Institute,Advanced Radiation Detection Instrument & Sensor Lab
[4] Sungkyunkwan University,WCU Department of Energy Science
来源
关键词
CdTe; Bridgman method; Am-241; Doping concentration; Semiconductor detectors;
D O I
暂无
中图分类号
学科分类号
摘要
A CdTe crystal ingot doped with 2000 ppm of Cl was grown by using the low-pressure Bridgman (LPB) method at the Korea Atomic Energy Research Institute (KAERI). A Semiconductor detector as a radiation detection sensor with a size of 7 (W) × 6.5 (D) × 2 (H) mm3 was fabricated from the CdTe ingot. In addition, the properties of the CdTe sample were observed through four kinds of experiments to analyze its performance. The resistivity was obtained as 1.41 × 1010 Ωcm by using a Keithley 6517A high-precision electrometer. The mobility-lifetime products for electrons and holes were 3.137 × 10-4 cm2/V and 4.868 × 10-5 cm2/V, respectively. Finally, we achieved a 16.8% energy resolution at 59.5 keV for the 241Am gamma-ray source. The CdTe semiconductor detector grown at KAERI has a performance good enough to detect low-energy gamma-rays.
引用
收藏
页码:27 / 30
页数:3
相关论文
共 50 条
  • [1] Growth and fabrication method of CdTe and its performance as a radiation detector
    Park S.
    Kim H.
    Kim D.
    Journal of the Korean Physical Society, 2015, 66 (1) : 31 - 36
  • [2] Growth and fabrication method of CdTe and its performance as a radiation detector
    Choi, Hyojeong
    Jeong, Manhee
    Kim, Han Soo
    Kim, Young Soo
    Ha, Jang Ho
    Chai, Jong-Seo
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 66 (01) : 27 - 30
  • [3] The CdTe detector module and its imaging performance
    Issei Mori
    Takuzo Takayama
    Nobutoku Motomura
    Annals of Nuclear Medicine, 2001, 15 : 487 - 494
  • [4] The CdTe detector module and its imaging performance
    Mori, I
    Takayama, T
    Motomura, N
    ANNALS OF NUCLEAR MEDICINE, 2001, 15 (06) : 487 - 494
  • [5] Fabrication and performance of CVD diamond radiation detector
    Zhou Hai-Yang
    Zhu Xiao-Dong
    Zhan Ru-Juan
    ACTA PHYSICA SINICA, 2010, 59 (03) : 1620 - 1624
  • [6] MOVPE Growth of CdTe on Si Substrates for Gamma Ray Detector Fabrication
    Niraula, Madan
    Yasuda, Kazuhito
    Watanabe, A.
    Kai, Y.
    Ichihashi, H.
    Yamada, W.
    Oka, H.
    Yoneyama, T.
    Nakashima, H.
    Nakanishi, T.
    Matsumoto, K.
    Katoh, D.
    Agata, Y.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) : 836 - 840
  • [7] Fabrication and performance of p-i-n CdTe radiation detectors
    Niraula, M
    Mochizuki, D
    Aoki, T
    Tomita, Y
    Nihashi, T
    Hatanaka, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2): : 132 - 137
  • [8] Improvement of the Productivity in the THM Growth of CdTe Single Crystal as Nuclear Radiation Detector
    Shiraki, Hiroyuki
    Funaki, Minoru
    Ando, Yukio
    Kominami, Shinya
    Amemiya, Kensuke
    Ohno, Ryoichi
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (01) : 395 - 399
  • [9] Formation of Schottky electrode for CdTe radiation detector
    Toyama, Hiroyuki
    Yamazato, Masaaki
    Higa, Akira
    Maehama, Takehiro
    Ohno, Ryoichi
    Toguchi, Minoru
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1395 - 1398
  • [10] PERFORMANCE OF CDTE AS A GAMMA SPECTROMETER AND DETECTOR
    ZANIO, K
    NEELAND, J
    MONTANO, H
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1970, NS17 (03) : 287 - &