Rice Slurry Analysis Using Mixed-Gas Plasma and Axially Viewed ICP OES

被引:0
|
作者
Guilherme Luiz Scheffler
Valderi Luiz Dressler
Dirce Pozebon
机构
[1] Universidade Federal do Rio Grande do Sul,Instituto de Química
[2] Universidade Federal de Santa Maria,Departamento de Química
来源
Food Analytical Methods | 2014年 / 7卷
关键词
Axially viewed ICP OES; Slurry; Rice; N; -Ar ICP;
D O I
暂无
中图分类号
学科分类号
摘要
This study deals with determination of essential and toxic elements in slurry of rice using axially viewed inductively coupled plasma optical emission spectrometry (ICP OES) and mixed gas plasma (N2-Ar ICP). Nitrogen was added (flow rate of 20 mL min−1) to the nebulizer gas through the spray chamber. It was observed that the addition of N2 increased the ICP robustness and mitigated the slurry matrix effects. Several parameters associated with the slurry preparation (extractant concentration, dispersant concentration, mass volume ratio of the slurry and sonication) were evaluated. The slurry was prepared in 10 % (m/v) HNO3 + 0.2 % (m/v) Triton X-100. Calibration was carried out with aqueous standards whereas Y(II) (371.029 nm) was used as internal standard (IS) in order to overcome matrix effects. The IS and sample solutions were mixed online. Accuracy was evaluated by the analysis of certified reference materials and by comparison with an independent method of sample preparation (acid digestion). The concentrations were consistent with those certified or found in digested rice sample. Calcium, Mg, K, Cd Cu, Fe, Mn, Mo, Cr, Zn, Co, Pb and Ni were investigated whose limits of detections were 0.080, 0.033, 0.050, 0.048, 0.050, 0.015, 0.005, 0.107, 0.036, 0.056, 0.040, 0.367 and 0.132 mg kg−1, respectively. The RSD (relative standard deviation) was typically lower than 10 %. Samples of parboiled, white, and brown rice were analysed and the concentrations found corroborate with those reported. It was concluded that calibration with aqueous standard is feasible, making the analysis simpler. The method is robust and can be routinely applied.
引用
收藏
页码:1415 / 1423
页数:8
相关论文
共 50 条
  • [1] Rice Slurry Analysis Using Mixed-Gas Plasma and Axially Viewed ICP OES
    Scheffler, Guilherme Luiz
    Dressler, Valderi Luiz
    Pozebon, Dirce
    FOOD ANALYTICAL METHODS, 2014, 7 (07) : 1415 - 1423
  • [2] Elemental analysis of nuts and seeds by axially viewed ICP OES
    Naozuka, Juliana
    Vieira, Edivan Carvalho
    Nascimento, Angerson Nogueira
    Oliveira, Pedro Vitoriano
    FOOD CHEMISTRY, 2011, 124 (04) : 1667 - 1672
  • [3] Effect of N2 on the emission profile and excitation temperature in axially viewed plasma-ICP OES
    Scheffler, Guilherme Luiz
    Pozebon, Dirce
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (02) : 468 - 478
  • [4] Partial leaching as an aid to slurry nebulization for the analysis of soils by ICP-MS with flow injection and mixed-gas plasmas
    Persaud, AT
    Beauchemin, D
    Jamieson, NE
    McLean, RJC
    CANADIAN JOURNAL OF CHEMISTRY-REVUE CANADIENNE DE CHIMIE, 1999, 77 (04): : 409 - 415
  • [5] INVESTIGATIONS ON MIXED-GAS PLASMAS PRODUCED BY ADDING NITROGEN TO THE PLASMA GAS IN ICP-MS
    BEAUCHEMIN, D
    CRAIG, JM
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1991, 46 (05) : 603 - 614
  • [6] Direct analysis of wheat flour by inductively coupled plasma mass spectrometry with flow injection, slurry nebulization, and a mixed-gas plasma
    Teuma-Castelletti, Robert
    Beauchemin, Diane
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (12) : 2820 - 2825
  • [7] Internal standardization in axially viewed inductively coupled plasma optical emission spectrometry (ICP OES) combined with pneumatic nebulization and aerosol desolvation
    Scheffler, Guilherme Luiz
    Pozebon, Dirce
    ANALYTICAL METHODS, 2013, 5 (17) : 4371 - 4377
  • [8] Analysis of powdered materials by slurry nebulization - ICP-OES
    Borszeki, J
    Halmos, P
    Gegus, E
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 1997, 42 (06): : 165 - 170
  • [9] Dilute-and-shoot procedure for the determination of mineral constituents in vinegar samples by axially viewed inductively coupled plasma optical emission spectrometry (ICP OES)
    Da Silva, J. C. J.
    Cadore, S.
    Nobrega, J. A.
    Baccan, N.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2007, 24 (02): : 130 - 139
  • [10] Metal Determination in Tea, Wheat, and Wheat Flour Using Diluted Nitric Acid, High-Efficiency Nebulizer, and Axially Viewed ICP OES
    Camila Alves Martins
    Camila Cerveira
    Guilherme Luiz Scheffler
    Dirce Pozebon
    Food Analytical Methods, 2015, 8 : 1652 - 1660