An electrochemical sensor for voltammetric detection of ciprofloxacin using a glassy carbon electrode modified with activated carbon, gold nanoparticles and supramolecular solvent

被引:0
|
作者
Netsirin Gissawong
Supalax Srijaranai
Suthasinee Boonchiangma
Pikaned Uppachai
Kompichit Seehamart
Sakwiboon Jantrasee
Eric Moore
Siriboon Mukdasai
机构
[1] Khon Kaen University,Materials Chemistry Research Center, Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science
[2] Rajamangala University of Technology Isan,Department of Applied Physics, Faculty of Engineering
[3] University College Cork,School of Chemistry and Tyndall National Institute
来源
Microchimica Acta | 2021年 / 188卷
关键词
Gold nanoparticles; Activated carbon; Supramolecular solvent; Ciprofloxacin; Electrochemical sensor;
D O I
暂无
中图分类号
学科分类号
摘要
A highly sensitive and novel electrochemical sensor for ciprofloxacin (CIP) has been developed using gold nanoparticles deposited with waste coffee ground activated carbon on glassy carbon electrode (AuNPs/AC/GCE) and combined with supramolecular solvent (SUPRAS). The fabricated AuNPs/AC/GCE displayed good electrocatalytic activity for AuNPs. The addition of SUPRAS, prepared from cationic surfactants namely didodecyldimethylammonium bromide (DDAB) and dodecyltrimethylammonium bromide (DTAB), increased the electrochemical response of AuNPs. The detection of CIP was based on the decrease of the cathodic current of AuNPs. The electrochemical behavior of the modified electrode was investigated using cyclic voltammetry, differential pulse voltammetry and electrochemical impedance spectroscopy. Under optimum conditions, the calibration plot of CIP exhibited a linear response in the range 0.5–25 nM with a detection limit of 0.20 nM. The fabricated electrochemical sensor was successfully applied to determine CIP in milk samples with achieved recoveries of 78.6–110.2% and relative standard deviations of <8.4%. The developed method was also applied to the analysis of pharmaceutical formulation and the results were compared with high-performance liquid chromatography.
引用
收藏
相关论文
共 50 条
  • [1] An electrochemical sensor for voltammetric detection of ciprofloxacin using a glassy carbon electrode modified with activated carbon, gold nanoparticles and supramolecular solvent
    Gissawong, Netsirin
    Srijaranai, Supalax
    Boonchiangma, Suthasinee
    Uppachai, Pikaned
    Seehamart, Kompichit
    Jantrasee, Sakwiboon
    Moore, Eric
    Mukdasai, Siriboon
    MICROCHIMICA ACTA, 2021, 188 (06)
  • [2] Voltammetric Sensing of Nifedipine Using a Glassy Carbon Electrode Modified with Carbon Nanofibers and Gold Nanoparticles
    Santos, Anderson M.
    Wong, Ademar
    Feitosa, Maria H. A.
    Cardenas-Riojas, Andy A.
    Calderon-Zavaleta, Sandy L.
    Baena-Moncada, Angelica M.
    Sotomayor, Maria D. P. T.
    Moraes, Fernando C.
    BIOSENSORS-BASEL, 2023, 13 (08):
  • [3] Electrochemical determination of ajmalicine using glassy carbon electrode modified with gold nanoparticles
    Eda Mehmeti
    Dalibor M. Stanković
    Sudkate Chaiyo
    Ľubomir Švorc
    Astrid Ortner
    Kurt Kalcher
    Monatshefte für Chemie - Chemical Monthly, 2016, 147 : 1161 - 1166
  • [4] Electrochemical determination of ajmalicine using glassy carbon electrode modified with gold nanoparticles
    Mehmeti, Eda
    Stankovic, Dalibor M.
    Chaiyo, Sudkate
    Svorc, L'ubomir
    Ortner, Astrid
    Kalcher, Kurt
    MONATSHEFTE FUR CHEMIE, 2016, 147 (07): : 1161 - 1166
  • [5] Electrochemical detection of ciprofloxacin based on graphene modified glassy carbon electrode
    Xie, A. -J.
    Chen, Y.
    Luo, S. -P.
    Tao, Y. -W.
    Jin, Y. -S.
    Li, W. -W.
    MATERIALS TECHNOLOGY, 2015, 30 (06) : 362 - 367
  • [6] An electrochemical sensor based on octahedral composite modified glassy carbon electrode for voltammetric detection of cocaine
    Oveili, Elham
    Jahani, Shohreh
    Tayari, Omid
    Jahanara, Abbas
    Fazli, Zohreh
    Aramesh-Boroujeni, Zahra
    Rashidi, Soroush
    Baravati, Nadia Rezaei Zade
    Foroughi, Mohammad Mehdi
    ELECTROANALYSIS, 2023, 35 (07)
  • [7] Voltammetric Response of Epinephrine at Carbon Nanotube Modified Glassy Carbon Electrode and Activated Glassy Carbon Electrode
    WANG Juan~1
    2. Department of Environmental Engineer
    WuhanUniversityJournalofNaturalSciences, 2005, (05) : 913 - 918
  • [8] Voltammetric determination of Cr(VI) using gold nanoparticles-modified glassy carbon electrode
    Wyantuti, Santhy
    Ishmayana, Safri
    Hartati, Yeni Wahyuni
    INTERNATIONAL SYMPOSIUM ON APPLIED CHEMISTRY 2015, 2015, 16 : 15 - 23
  • [9] Electrochemical sensor for amino acids based on gold nanoparticles/macroporous carbon composites modified glassy carbon electrode
    Zeng, Lijun
    Wang, Huan
    Bo, Xiangjie
    Guo, Liping
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 687 : 117 - 122
  • [10] Voltammetric Detection of Paracetamol at Cobalt Ferrite Nanoparticles Modified Glassy Carbon Electrode
    Kumary, V. Anitha
    Divya, J.
    Nancy, T. E. Mary
    Sreevalsan, K.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (05): : 6610 - 6619