Controlled Comparison of Simulated Hemodynamics Across Tricuspid and Bicuspid Aortic Valves

被引:0
|
作者
Alexander D. Kaiser
Rohan Shad
Nicole Schiavone
William Hiesinger
Alison L. Marsden
机构
[1] Stanford University,Institute for Computational & Mathematical Engineering
[2] Stanford University,Department of Pediatrics (Cardiology)
[3] Stanford Cardiovascular Institute,Department of Cardiothoracic Surgery
[4] Stanford University,Department of Mechanical Engineering
[5] Stanford University,Department of Bioengineering
[6] Stanford University,undefined
来源
关键词
Bicuspid aortic valve; Aortic valve modeling; Aortic aneurysm; Immersed boundary method; Heart valve fluid–structure interaction;
D O I
暂无
中图分类号
学科分类号
摘要
Bicuspid aortic valve is the most common congenital heart defect, affecting 1–2% of the global population. Patients with bicuspid valves frequently develop dilation and aneurysms of the ascending aorta. Both hemodynamic and genetic factors are believed to contribute to dilation, yet the precise mechanism underlying this progression remains under debate. Controlled comparisons of hemodynamics in patients with different forms of bicuspid valve disease are challenging because of confounding factors, and simulations offer the opportunity for direct and systematic comparisons. Using fluid–structure interaction simulations, we simulate flows through multiple aortic valve models in a patient-specific geometry. The aortic geometry is based on a healthy patient with no known aortic or valvular disease, which allows us to isolate the hemodynamic consequences of changes to the valve alone. Four fully-passive, elastic model valves are studied: a tricuspid valve and bicuspid valves with fusion of the left- and right-, right- and non-, and non- and left-coronary cusps. The resulting tricuspid flow is relatively uniform, with little secondary or reverse flow, and little to no pressure gradient across the valve. The bicuspid cases show localized jets of forward flow, excess streamwise momentum, elevated secondary and reverse flow, and clinically significant levels of stenosis. Localized high flow rates correspond to locations of dilation observed in patients, with the location related to which valve cusps are fused. Thus, the simulations support the hypothesis that chronic exposure to high local flow contributes to localized dilation and aneurysm formation.
引用
收藏
页码:1053 / 1072
页数:19
相关论文
共 50 条
  • [1] Controlled Comparison of Simulated Hemodynamics Across Tricuspid and Bicuspid Aortic Valves
    Kaiser, Alexander D.
    Shad, Rohan
    Schiavone, Nicole
    Hiesinger, William
    Marsden, Alison L.
    ANNALS OF BIOMEDICAL ENGINEERING, 2022, 50 (09) : 1053 - 1072
  • [2] AORTIC DISSECTION IN PATIENTS WITH BICUSPID AORTIC VALVES: CLINICAL AND PATHOLOGIC COMPARISON WITH TRICUSPID VALVES
    Eleid, Mackram
    Forde, Inga
    Edwards, William
    Suri, Rakesh
    Maleszewski, Joseph
    Schaff, Hartzell
    Enriquez-Sarano, Maurice
    Michelena, Hector
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E1970 - E1970
  • [3] Ascending Aortic Wall Cohesion: Comparison of Bicuspid and Tricuspid Valves
    Benedik, Jaroslav
    Pilarczyk, Kevin
    Wendt, Danie
    Indruch, Jiri
    Flek, Radek
    Tsagakis, Konstantinos
    Alaeddine, Savvas
    Jakob, Heinz
    CARDIOLOGY RESEARCH AND PRACTICE, 2012, 2012
  • [4] Type A aortic dissection in patients with bicuspid aortic valves: clinical and pathological comparison with tricuspid aortic valves
    Eleid, Mackram F.
    Forde, Inga
    Edwards, William D.
    Maleszewski, Joseph J.
    Suri, Rakesh M.
    Schaff, Hartzell V.
    Enriquez-Sarano, Maurice
    Michelena, Hector I.
    HEART, 2013, 99 (22) : 1668 - 1674
  • [5] Biomechanics of Aortic Dissection: A Comparison of Aortas Associated With Bicuspid and Tricuspid Aortic Valves
    Chung, Jennifer C. -Y.
    Wong, Edwin
    Tang, Mingyi
    Eliathamby, Daniella
    Forbes, Thomas L.
    Butany, Jagdish
    Simmons, Craig A.
    Ouzounian, Maral
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2020, 9 (15):
  • [6] Aortic dimensions in patients with bicuspid and tricuspid aortic valves
    Jackson, Veronica
    Olsson, Christian
    Eriksson, Per
    Franco-Cereceda, Anders
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 146 (03): : 605 - 610
  • [7] Differences between stenotic bicuspid and tricuspid aortic valves: a histological comparison
    Wu, H. W.
    El Ouraoui, M.
    Hjortnaes, J.
    Palmen, M.
    Klautz, R. J. M.
    Jukema, J. W.
    Marsan, N. Ajmone
    EUROPEAN HEART JOURNAL, 2024, 45
  • [8] Differences between stenotic bicuspid and tricuspid aortic valves: a histological comparison
    Wu, H. W.
    El Ouraoui, M.
    Hjortnaes, J.
    Palmen, M.
    Klautz, R. J. M.
    Jukema, J. W.
    Ajmone Marsan, N.
    EUROPEAN HEART JOURNAL, 2024, 45
  • [9] Editorial: Bicuspid versus tricuspid aortic valves
    Robicsek, F
    JOURNAL OF HEART VALVE DISEASE, 2003, 12 (01): : 52 - 53
  • [10] A multiscale computational comparison of the bicuspid and tricuspid aortic valves in relation to calcific aortic stenosis
    Weinberg, Eli J.
    Mofrad, Mohammad R. Kaazempur
    JOURNAL OF BIOMECHANICS, 2008, 41 (16) : 3482 - 3487