Analysis of leakage failure in a domestic hydraulic installation assisted by pitting corrosion of water tube

被引:4
|
作者
Pantazopoulos G. [1 ]
机构
[1] ELKEME Hellenic Research Centre for Metals S.A., Athens 17778
关键词
Corrosion deposits; DHP-copper; Leakage failure; Pitting corrosion;
D O I
10.1007/s11668-009-9274-6
中图分类号
学科分类号
摘要
Deoxidized high phosphorus copper (C12200, DHP-Cu) is the principal construction material in hydraulic and heating ventilation and air-conditioning installations due to its excellent thermal/electrical conductivity, formability, corrosion resistance and antimicrobial properties. However, design and installation deficiencies or aggressive environmental conditions, such as improper water chemistry, may lead to unexpected failures. A corroded copper water tube caused leakage in a domestic hydraulic installation close to the sea coast area. The leakage was reported after short-time period in service. After installation the pipeline was not in continuous operation and remained unused for approximately 3-6 months per year. Tubes were disconnected from a hydraulic installation and samples were taken for failure investigation. Failure analysis findings suggest strongly that the leakage was caused by tube perforation from the waterside by severe localized pitting corrosion. The main cause of the accelerated tube pitting corrosion was probably the improper water quality (high hardness and electrical conductivity) but the potential for an aggressive environment created by substances, such as chlorides and organic compounds, could not be excluded. © 2009 ASM International.
引用
收藏
页码:479 / 485
页数:6
相关论文
共 50 条
  • [1] Failure analysis of a hard-drawn water tube leakage caused by the synergistic actions of pitting corrosion and stress-corrosion cracking
    Pantazopoulos, G.
    Vazdirvanidis, A.
    Tsinopoulos, G.
    ENGINEERING FAILURE ANALYSIS, 2011, 18 (02) : 649 - 657
  • [2] Investigation of cold water pitting corrosion failure of deoxidized high phosphorus (DHP) copper tube A case study
    Pantazopoulos, George
    Vazdirvanidis, Athanasios
    Rikos, Andreas
    Skarmoutsos, Dionysios
    INTERNATIONAL JOURNAL OF STRUCTURAL INTEGRITY, 2016, 7 (05) : 599 - 606
  • [3] Failure analysis and experimental verification on the hydrogen-driven pitting corrosion of heat exchanger tube material
    Liu, Dong
    Hu, Junying
    Yuan, Xi
    Zhou, Li
    Zhong, Xiankang
    ENGINEERING FAILURE ANALYSIS, 2022, 137
  • [4] Pitting corrosion failure analysis of a wet gas pipeline
    Mansoori, Hamed
    Mirzaee, Reza
    Esmaeilzadeh, Feridun
    Vojood, Arash
    Dowrani, Alireza Soltan
    ENGINEERING FAILURE ANALYSIS, 2017, 82 : 16 - 25
  • [5] Analysis and identification of leakage failure in hydraulic system of hydraulic powered support
    Yao, ZC
    Yang, ZY
    Lin, B
    MINING SCIENCE AND TECHNOLOGY 99, 1999, : 743 - 746
  • [6] Analysis and identification of leakage failure in hydraulic system of hydraulic powered support
    Yao, Zhichang
    Wang, Xiaolei
    Le, Jun
    Yang, Zhiyi
    Chen, Xiangwen
    He, Fulian
    Qian, Minggao
    Meitan Kexun Jishu/Coal Science and Technology (Peking), 25 (11): : 7 - 9
  • [7] Hydraulic analysis on leakage of water supply pipeline
    Wang, Jie
    Jia, Hui
    Zhang, Hong-Wei
    Li, Hong-Xia
    Shuili Xuebao/Journal of Hydraulic Engineering, 2008, 39 (08): : 1001 - 1004
  • [8] THE EFFECT OF WATER-QUALITY ON PITTING CORROSION OF COPPER TUBE IN HOT SOFT-WATER
    FUJII, T
    KODAMA, T
    BABA, H
    CORROSION SCIENCE, 1984, 24 (10) : 901 - 912
  • [9] Failure analysis of an oil pipe wall perforated by pitting corrosion
    Zhang, Shaohua
    Hou, Lifeng
    Wei, Huan
    Wei, Yinghui
    Liu, Baosheng
    MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2018, 69 (08): : 1123 - 1130
  • [10] Copper Tube Pitting in Santa Fe Municipal Water Caused by Microbial Induced Corrosion
    Burleigh, Thomas D.
    Gierke, Casey G.
    Fredj, Narjes
    Boston, Penelope J.
    MATERIALS, 2014, 7 (06) : 4321 - 4334