Determination of the rate of atmospheric corrosion of metal structures by the method of polarization resistance

被引:0
|
作者
L. I. Nyrkova
S. H. Polyakov
S. O. Osadchuk
S. L. Mel’nychuk
N. O. Hapula
机构
[1] Ukrainian National Academy of Sciences,Paton Institute of Electric Welding
来源
Materials Science | 2012年 / 47卷
关键词
corrosion rate; electrochemical sensor for measuring the rate of atmospheric corrosion; thin layer of a humid film; atmospheric humidity; method of polarization resistance;
D O I
暂无
中图分类号
学科分类号
摘要
We consider a method aimed at the determination of the rate of atmospheric corrosion in metallic structures according to the polarization resistance based on the use of multielectrode sensors with cosurface location of the electrodes (applied to increase the sensitivity of measurements). The serviceability of four models of electrochemical sensors intended for the monitoring of metallic structures under the conditions of atmospheric corrosion for an atmospheric humidity of 100 % and temperatures of 24, 40, 50, and 70°C is investigated. It is shown that, by decreasing the thickness of the insulating interlayer, the width of electrodes, and their number, it is possible to increase the accuracy and sensitivity of measurements of the corrosion rate in humid atmospheres. The developed sensors prove to be suitable for the purposes of monitoring of the corrosion rate in metallic structures operating under the atmospheric conditions, including closed volumes.
引用
收藏
页码:683 / 688
页数:5
相关论文
共 50 条
  • [1] Determination of the rate of atmospheric corrosion of metal structures by the method of polarization resistance
    Nyrkova, L. I.
    Polyakov, S. H.
    Osadchuk, S. O.
    Mel'nychuk, S. L.
    Hapula, N. O.
    MATERIALS SCIENCE, 2012, 47 (05) : 683 - 688
  • [2] DETERMINATION OF POLARIZATION RESISTANCE AND CORROSION RATE BY USING PULSE METHOD, POLARIZATION CURVES AND AAS
    METIKOSHUKOVIC, M
    ZEVNIK, C
    WERKSTOFFE UND KORROSION-MATERIALS AND CORROSION, 1982, 33 (12): : 661 - 668
  • [3] Polarization resistance method for determination of instantaneous corrosion rates
    Scully, JR
    CORROSION, 2000, 56 (02) : 199 - 218
  • [4] DETERMINATION OF THE CORROSION RATE OF STEEL IN CONCRETE FROM THE POLARIZATION RESISTANCE
    ROZENTAL, NK
    PROTECTION OF METALS, 1988, 24 (04): : 559 - 561
  • [5] CORROSION RATE DETERMINATION ON PLANTS THROUGH POLARIZATION RESISTANCE MEASUREMENTS
    TRABANELLI, G
    ZUCCHI, F
    MANTOVAN.G
    CHIMICA & L INDUSTRIA, 1973, 55 (12): : 958 - 961
  • [6] Estimation of the accuracy of measurements of the corrosion rate by the method of polarization resistance
    Gerasimenko, US
    Belousova, NA
    Nechai, MV
    Shlokova, EA
    MATERIALS SCIENCE, 1995, 31 (03) : 302 - 306
  • [7] Estimation of accuracy of corrosion rate measurement by polarization resistance method
    Gerasymenko, Ju.S.
    Belousova, N.A.
    Nechaj, M.V.
    Shlokova, O.O.
    Fiziko-Khimicheskaya Mekhanika Materialov, 31 (03): : 22 - 27
  • [8] DETERMINATION OF INSTANTANEOUS RATE OF ATMOSPHERIC CORROSION
    GONZALEZ, JA
    WERKSTOFFE UND KORROSION-MATERIALS AND CORROSION, 1978, 29 (07): : 456 - 460
  • [9] Programmable linear polarization meter for determination of corrosion rate of reinforcement in concrete structures
    Gowers, K.R.
    Millard, S.G.
    Gill, J.S.
    Gill, R.P.
    British Corrosion Journal, 1994, 29 (01): : 25 - 32
  • [10] DETERMINATION OF CORROSION RATE OF CATHODICALLY PROTECTED STEEL IN NEUTRAL MEDIA BY POLARIZATION RESISTANCE
    SOROKIN, VI
    PROTECTION OF METALS, 1993, 29 (03): : 373 - 376