Improving rigid fiberoptic intubation: A comparison of the Bonfils Intubating Fiberscope™ with a novel modification

被引:7
|
作者
Boedeker B.H. [1 ,2 ]
Barak-Bernhagen M.A. [1 ,2 ]
Miller D.J. [1 ]
Nicholas IV T.A. [1 ]
Linnaus A. [1 ]
Murray W.B. [3 ]
机构
[1] University of Nebraska Medical Center, Omaha, NE
[2] Omaha VA Medical Center, Omaha, NE
[3] Clinical Simulation Center, Penn State College of Medicine, Hershey, PA
关键词
Difficult Airway; Cricoid Pressure; Intubation Attempt; Anesthesia Provider; Awake Intubation;
D O I
10.1186/1471-227X-10-11
中图分类号
学科分类号
摘要
Background: The Bonfils intubating fiberscope has a limited upward tip angle of 40° and requires retromolar entry into the hypopharynx. These factors may make its use less desirable when managing the difficult airway because most anesthesia providers are well versed in midline oral intubation rather than the lateral retromolar approach. The Center for Advanced Technology and Telemedicine at the University of Nebraska Medical Center has developed a novel fiberscope with a more anterior 60° curve to allow for easier midline insertion and intubation. The objective of this work was to evaluate the novel fiberscope, in comparison to the Bonfils intubating fiberscope, in terms of use and function in difficult airway intubation.Methods: Twenty-two anesthesia providers participated in simulated intubations of a difficult airway mannequin to compare the Bonfils intubating fiberscope with the novel curved Boedeker intubating fiberscope. The intubations were assessed based upon the following variables: recorded Cormack Lehane airway scores, requests for cricoid pressure, time to intubation, number of intubation attempts and success or failure of the procedure.Results: Participants using the Bonfils fiberscope recorded an average Cormack Lehane (CL) airway score of 1.67 ± 1.02 (median = 1); with the novel fiberscope, the recorded average airway grade improved to 1.18 ± 0.50 (median = 1). The difference in airway scores was not statistically significant (p = 0.34; Fishers Exact Test comparing CL grades 1&2 vs. 3&4). There was, however, a statistically significant difference in intubation success rates between the two devices. With the Bonfils fiberscope, 68% (15/22) of participants were successful in intubation compared to a 100% success rate in intubation with the novel fiberscope (22/22) (p = 0.008). After the intubation trial, the majority of participants (95%) indicated a preference for the novel fiberscope (n = 20).Conclusions: With this data, we can infer that the novel fiberscope curvature appears to improve or maintain the quality of an intubation attempt (airway score, cricoid pressure requirement, intubation time, number of attempts, placement success). The data indicate that the novel fiberscope offers a superior intubation experience to currently available best practices. The instrument was well received and would be welcomed by most study participants should the device become clinically available in the future. © 2010 Boedeker et al; licensee BioMed Central Ltd.
引用
收藏
相关论文
共 30 条
  • [1] Tracheal intubation with the Bonfils fiberscope in the difficult pediatric airway: a comparison with fiberoptic intubation
    Kaufmann, Jost
    Laschat, Michael
    Engelhardt, Thomas
    Hellmich, Martin
    Wappler, Frank
    PEDIATRIC ANESTHESIA, 2015, 25 (04) : 372 - 378
  • [2] Predictors of Difficult Intubation with the Bonfils Rigid Fiberscope
    Nowakowski, Michal
    Williams, Stephan
    Gallant, Jason
    Ruel, Monique
    Robitaille, Arnaud
    ANESTHESIA AND ANALGESIA, 2016, 122 (06): : 1901 - 1906
  • [3] An unexpected difficult intubation. Bonfils rigid fiberscope
    Maybauer, MO
    Maier, S
    Thierbach, AR
    ANAESTHESIST, 2005, 54 (01): : 35 - 39
  • [4] Difficult airway intubation simulation using Bonfils fiberscope and rigid fiberscope for surgical training
    Dharmarajan, Harish
    Liu, Yi-Chun Carol
    Hippard, Helena Karlberg
    Chandy, Binoy
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2018, 105 : 171 - 175
  • [5] Comparing intubation performance of Bonfils fiberscope and fiberoptic bronchoscope in difficult pediatric airways
    Liu, Gao Pu
    Li, Rui Ping
    Xue, Fu Shan
    PEDIATRIC ANESTHESIA, 2015, 25 (02) : 217 - 217
  • [6] A Comparison Between the Bonfils Intubation Fiberscope and McCoy Laryngoscope for Tracheal Intubation in Patients with a Simulated Difficult Airway
    Abdullah, Hairil Rizal
    Li-Ming, Teo
    Marriott, Andrew
    Wong, Theodore Gar-Ling
    ANESTHESIA AND ANALGESIA, 2013, 117 (05): : 1217 - 1220
  • [7] A COMPARISON OF FIBEROPTIC OROTRACHEAL INTUBATION USING 2 DIFFERENT INTUBATING CONDUITS
    HAGBERG, C
    ABRAMSON, D
    CHELLY, J
    ANESTHESIOLOGY, 1995, 83 (3A) : A1220 - A1220
  • [8] A comparison of Bonfils intubation fiberscopy and fiberoptic bronchoscopy in difficult airways assisted with direct laryngoscopy
    Kim, Soo Hwan
    Woo, Su Jin
    Kim, Jong Hoon
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2010, 58 (03) : 249 - 255
  • [9] A comparison of the intubating laryngeal mask airway and the Bonfils intubation fibrescope in patients with predicted difficult airways
    Bein, B
    Worthmann, F
    Scholz, J
    Brinkmann, F
    Tonner, PH
    Steinfath, M
    Dörges, V
    ANAESTHESIA, 2004, 59 (07) : 668 - 674
  • [10] Comparison of haemodynamic responses to intubation: Flexible fibreoptic bronchoscope versus bonfils rigid intubation endoscope
    Gupta, Kapil
    Girdhar, Kiran Kumar
    Anand, Raktima
    Majgi, Sumanth Mallikarjuna
    Gupta, Surinder Pal
    Gupta, Payal Bansal
    INDIAN JOURNAL OF ANAESTHESIA, 2012, 56 (04) : 353 - 358