Non-calcified coronary atherosclerotic plaque visualization on CT: effects of contrast-enhancement and lipid-content fractions

被引:0
|
作者
Wisnumurti Kristanto
Peter M. A. van Ooijen
Marcel J. W. Greuter
Jaap M. Groen
Rozemarijn Vliegenthart
Matthijs Oudkerk
机构
[1] University Medical Center Groningen,Department of Radiology, Center for Medical Imaging
[2] University of Groningen,North East Netherlands
关键词
Coronary artery disease; Non-calcified atherosclerotic plaques characterization; Computed tomography angiography; Software phantoms; Simulation study;
D O I
暂无
中图分类号
学科分类号
摘要
Computed tomography (CT) may characterize lipid-rich and presumably rupture-prone non-calcified coronary atherosclerotic plaque based on its Hounsfield-Unit (HU), but still inconclusively. This study aimed to evaluate factors influencing the HU-value of non-calcified plaque using software simulation. Several realistic virtual plaqueburdened coronary phantoms were constructed at 5 μm resolution. CT scanning was simulated with settings resembling a 64-row multi-detector CT (64-MDCT) and reconstructed at 64-MDCT (0.4 mm) and MicroCT (48 μm) resolutions. Influences of lumen contrast-enhancement, stenosis-grades, and plaque compositions on plaque visualization were analyzed. Lumen contrast-enhancement and mean plaque HU-value were positively correlated (R2 > 0.92), with approximately the same slopes for all plaque compositions. Percentage lipid-content and mean plaque HU-value were negatively correlated (R2 > 0.98). Stenosis-grade and noise had minimal influence on the correlations. Influence of lumen contrast-enhancement on plaque HU-value was following a specific exponentially declining pattern (y = Ae−λx + c) from the lumen border until 2-pixel radius. Outside 2-pixel radius, plaque HU-values deviated maximally 5 HU from non-contrast-enhanced reference. Thus, to avoid lumen contrast-enhancement influence, plaques should be measured outside 2-pixel radius from the lumen border. Based on the patterns found, a lumen influence correction algorithm may be developed. HU-based plaque percentage lipid-content determination might serve as an alternative plaque characterization method. However, its applicability is still hindered by many inherent limitations.
引用
收藏
页码:1137 / 1148
页数:11
相关论文
共 38 条
  • [1] Non-calcified coronary atherosclerotic plaque visualization on CT: effects of contrast-enhancement and lipid-content fractions
    Kristanto, Wisnumurti
    van Ooijen, Peter M. A.
    Greuter, Marcel J. W.
    Groen, Jaap M.
    Vliegenthart, Rozemarijn
    Oudkerk, Matthijs
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (05): : 1137 - 1148
  • [2] Correction of lumen contrast-enhancement influence on non-calcified coronary atherosclerotic plaque quantification on CT
    Kristanto, Wisnumurti
    Tuncay, Volkan
    Vliegenthart, Rozemarijn
    van Ooijen, Peter M. A.
    Oudkerk, Matthijs
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 (02): : 429 - 436
  • [3] Correction of lumen contrast-enhancement influence on non-calcified coronary atherosclerotic plaque quantification on CT
    Wisnumurti Kristanto
    Volkan Tuncay
    Rozemarijn Vliegenthart
    Peter M. A. van Ooijen
    Matthijs Oudkerk
    The International Journal of Cardiovascular Imaging, 2015, 31 : 429 - 436
  • [4] Non-calcified plaque-based coronary stenosis grading in contrast enhanced CT
    Jawaid, Muhammad Moazzam
    Narejo, Sanam
    Riaz, Farhan
    Reyes-Aldasoro, Constantino Carlos
    Slabaugh, Greg
    Brown, James
    MEDICAL ENGINEERING & PHYSICS, 2024, 129
  • [5] Influence of age and cardiovascular risk factors on the presence of calcified and non-calcified coronary atherosclerotic plaque detected by coronary CT angiography
    Geckeis, K.
    Achenbach, S.
    Ropers, D.
    Renz, A.
    Daniel, W. G.
    EUROPEAN HEART JOURNAL, 2008, 29 : 618 - 618
  • [6] Characterization of non-calcified coronary atherosclerotic plaque by multi-detector row CT: Comparison to IVUS
    Pohle, Karsten
    Achenbach, Stephan
    MacNeill, Briain
    Ropers, Dieter
    Ferencik, Maros
    Moselewski, Fabian
    Hoffmann, Udo
    Brady, Thomas J.
    Jang, Ik-Kyung
    Daniel, Werner G.
    ATHEROSCLEROSIS, 2007, 190 (01) : 174 - 180
  • [7] Non-Calcified Coronary Atherosclerotic Plaque Characterization by Dual Energy Computed Tomography
    Yamak, Didem
    Panse, Prasad
    Pavlicek, William
    Boltz, Thomas
    Akay, Metin
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2014, 18 (03) : 939 - 945
  • [8] Incremental detection of coronary artery disease by assessment of non-calcified plaque on coronary CT angiography
    Venkatesh, V.
    Ellins, M. L.
    Yang, S.
    Natarajan, M.
    Amlani, S.
    Sheth, T.
    CLINICAL RADIOLOGY, 2009, 64 (03) : 250 - 255
  • [9] Progression of non-calcified coronary atherosclerotic plaque: assessment by 64-slice computed tomography
    Schmid, M.
    Pflederer, T.
    Ropers, U.
    Wechsel, M.
    Marwan, M.
    Ropers, D.
    Daniel, W. G.
    Achenbach, S.
    EUROPEAN HEART JOURNAL, 2006, 27 : 426 - 426
  • [10] Interobserver variability of 64-slice computed tomography for the quantification of non-calcified coronary atherosclerotic plaque
    Plflederer, T.
    Schmid, M.
    Ropers, D.
    Rapers, U.
    Komatsu, S.
    Daniel, W. G.
    Achenbach, S.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2007, 179 (09): : 953 - 957