Multicenter study for the evaluation of a dedicated biopsy device for MR-guided vacuum biopsy of the breast

被引:0
|
作者
C. Perlet
A. Heinig
X. Prat
J. Casselman
L. Baath
H. Sittek
C. Stets
J. Lamarque
I. Anderson
P. Schneider
P. Taourel
M. Reiser
S. Heywang-Köbrunner
机构
[1] Institute of Clinical Radiology,
[2] Ludwig Maximilians University,undefined
[3] Klinikum Grosshadern,undefined
[4] Marchioninistrasse 15,undefined
[5] 81377 Munich,undefined
[6] Germany,undefined
[7] Department of Diagnostic Radiology,undefined
[8] Martin-Luther University,undefined
[9] Halle,undefined
[10] Germany,undefined
[11] Département d'Imagerie Médicale,undefined
[12] Hospital Lapeyronie,undefined
[13] Montpellier Cédex,undefined
[14] France,undefined
[15] Diagnostic Radiology,undefined
[16] AZ St. Jan Hospital,undefined
[17] Brugge,undefined
[18] Belgium,undefined
[19] Department of Radiology,undefined
[20] Malmö University Hospital,undefined
[21] Malmö,undefined
[22] Sweden,undefined
来源
European Radiology | 2002年 / 12卷
关键词
Breast MR imaging Biopsy Intervention;
D O I
暂无
中图分类号
学科分类号
摘要
The purpose of this multicenter study was to determine the accuracy and clinical value of a dedicated breast biopsy system which allows for MR-guided vacuum biopsy (VB) of contrast-enhancing lesions. In five European centers, MR-guided 11-gauge VB was performed on 341 lesions. In 7 cases VB was unsuccessful. This was immediately realized on postinterventional images or direct follow-up combined with histopathology-imaging correlation; thus, a false-negative diagnosis was avoided. Histology of 334 successful biopsies yielded 84 (25%) malignancies, 17 (5%) atypical ductal hyperplasias, and 233 (70%) benign entities. Verification of malignant or borderline lesions included reexcision of the biopsy cavity. Benign histologic biopsy results were verified by retrospective correlation with the pre- and postinterventional MRI and by subsequent follow-up. Our results indicate that MR-guided VB, in combination with the dedicated biopsy coil, offers the possibility to accurately diagnose even very small lesions that can only be visualized or localized by MRI.
引用
收藏
页码:1463 / 1470
页数:7
相关论文
共 50 条
  • [1] Multicenter study for the evaluation of a dedicated biopsy device for MR-guided vacuum biopsy of the breast
    Perlet, C
    Heinig, A
    Prat, X
    Casselman, J
    Baath, L
    Sittek, H
    Stets, C
    Lamarque, J
    Anderson, I
    Schneider, P
    Taourel, P
    Reiser, M
    Heywang-Köbrunner, SH
    EUROPEAN RADIOLOGY, 2002, 12 (06) : 1463 - 1470
  • [2] European multicenter study on MR-guided vacuum biopsy of the breast: Clinical results
    Perlet, CH
    Prat, X
    Casselman, JW
    Barentsz, JO
    Sittek, H
    Heywang-Koebrunner, SH
    RADIOLOGY, 2002, 225 : 556 - 556
  • [3] European multicenter study on MR-guided vacuum biopsy of the breast: Results of phase I and II
    Perlet, C
    Prat, X
    Sittek, H
    Casselman, I
    Heinig, A
    Heywang-Koebrunner, SH
    RADIOLOGY, 2001, 221 : 378 - 378
  • [4] Multicenter-study on MR-guided breast localisation and vacuum biopsy - First year report
    Heywang-Koebrunner, SH
    Sittek, H
    Prat, X
    Baath, L
    Lamarque, J
    Heinig, A
    RADIOLOGY, 2000, 217 : 493 - 493
  • [5] MR-guided breast biopsy
    SH Heywang-Köbrunner
    H Sittek
    X Prat
    L Baath
    Breast Cancer Research, 2 (Suppl 2)
  • [6] MR-guided vacuum assisted breast biopsy with the ATEC® breast biopsy and excision system
    Hauth, E. A.
    Umutlu, L.
    Quinsten, A.
    Kuemmel, S.
    Kimmig, R.
    Forsting, M.
    GEBURTSHILFE UND FRAUENHEILKUNDE, 2008, 68 (09) : 901 - 906
  • [7] Clip marker placement following MR-guided vacuum biopsy of the breast
    Perlet, C
    Sittek, H
    Reiser, M
    Heywang-Köbrunner, SH
    RADIOLOGE, 2005, 45 (03): : 230 - +
  • [8] MR-guided interventional breast procedures considering vacuum biopsy in particular
    Viehweg, P
    Heinig, A
    Amaya, B
    Alberich, T
    Laniado, M
    Heywang-Köbrunner, SH
    EUROPEAN JOURNAL OF RADIOLOGY, 2002, 42 (01) : 32 - 39
  • [9] MR-guided vacuum-assisted breast biopsy: is it an essential technique?
    Mitsuhiro Tozaki
    Norie Yamashiro
    Takako Suzuki
    Naoko Kawano
    Shinji Ozaki
    Naomi Sakamoto
    Satoko Abe
    Tomoko Ogawa
    Nobuhito Katayama
    Yuko Tsunoda
    Eisuke Fukuma
    Breast Cancer, 2009, 16
  • [10] MR-guided vacuum-assisted breast biopsy: is it an essential technique?
    Tozaki, Mitsuhiro
    Yamashiro, Norie
    Suzuki, Takako
    Kawano, Naoko
    Ozaki, Shinji
    Sakamoto, Naomi
    Abe, Satoko
    Ogawa, Tomoko
    Katayama, Nobuhito
    Tsunoda, Yuko
    Fukuma, Eisuke
    BREAST CANCER, 2009, 16 (02) : 121 - 125