Long term and equilibrium factor indoor radon measurements

被引:0
|
作者
T. Martinez
J. Lartigue
M. Navarrete
L. Cabrera
P. Gonzalez
A. Ramirez
V. Elizarraras
机构
[1] National University of Mexico,Faculty of Chemistry
[2] National Institute of Nuclear Research Sierra Mojada 447-20,undefined
来源
Journal of Radioanalytical and Nuclear Chemistry | 1998年 / 236卷
关键词
Radon; Radon Concentration; Indoor Radon; Radon Level; Monitoring Campaign;
D O I
暂无
中图分类号
学科分类号
摘要
This paper presents the annual radon gas concentrations obtained during the 1994–1995 monitoring campaign using passive electret system (type E-PERM). Radon levels were measured in 154 single family dwellings, in normal occupancy conditions (open house condition) in the metropolitan zone of Mexico City. At the same time radon monitoring was performed outdoors. The results show the general log-normal distribution of integrated indoor radon concentration with an annual indoor mean of 3.8 pCi·l−1. The seasonal variations show the minimum mean values in the summer season which are 39% lower than that in autumn. Equilibrium factors (F) were measured in 12 typical houses both in autumn and winter using a continuous working level monitor for short-lived radon decay products and H-chamber loaded with a short term electret (HST, E-PERM) for radon gas. The obtained total mean equilibrium factors are:F=0.41±0.17 andF=0.29±0.04 for indoor and outdoor, respectively. A quality program was also improved.
引用
收藏
页码:231 / 238
页数:7
相关论文
共 50 条
  • [1] LONG TERM MEASUREMENTS OF INDOOR RADON EQUILIBRIUM FACTOR
    Harley, Naomi H.
    Chen, Jing
    Chittaporn, Passaporn
    Sorimachi, Atsuyuki
    Tokonami, Shinji
    HEALTH PHYSICS, 2012, 102 (04): : 459 - 462
  • [2] Long term and equilibrium factor indoor radon measurements
    Martinez, T
    Lartigue, J
    Navarrete, M
    Cabrera, L
    Gonzalez, P
    Ramirez, A
    Elizarraras, V
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1998, 236 (1-2) : 231 - 237
  • [3] Long Term Measurements of Indoor Radon Equilibrium Factor (vol 102, pg 459, 2012)
    Harley, N. H.
    Chen, J.
    Chittaporn, P.
    Sorimachi, A.
    Tokonami, S.
    HEALTH PHYSICS, 2012, 102 (06): : 709 - 709
  • [4] Long term measurements of radon equilibrium factor in Greek dwellings
    Clouvas, A
    Xanthos, S
    Antonopoulos-Domis, M
    RADIATION PROTECTION DOSIMETRY, 2003, 103 (03) : 269 - 272
  • [5] SHORT-TERM VS LONG-TERM INDOOR RADON MEASUREMENTS
    QUINDOS, LS
    FERNANDEZ, PL
    SOTO, J
    HEALTH PHYSICS, 1991, 61 (04): : 539 - 542
  • [6] On the long term indoor radon concentration measurements the basement of Japanese hospitals
    Shiotsu, M
    Ikeda, K
    Yosizawa, S
    Iida, T
    RADON AND THORON IN THE HUMAN ENVIRONMENT, 1998, : 391 - 396
  • [7] An evaluation of thoron (and radon) equilibrium factor close to walls based on long-term measurements in dwellings
    Mishra, R.
    Zunic, Z. S.
    Venoso, G.
    Bochicchio, F.
    Stojanovska, Z.
    Carpentieri, C.
    Prajith, R.
    Sapra, B. K.
    Mayya, Y. S.
    Ishikawa, T.
    Omori, Y.
    Veselinovic, N.
    Tollefsen, T.
    Ujic, P.
    Bossew, P.
    RADIATION PROTECTION DOSIMETRY, 2014, 160 (1-3) : 164 - 168
  • [8] Long term indoor radon measurements in the pelletron laboratory at the UNAM physics institute
    Espinosa, G.
    Golzarri, J. I.
    Lopez, K.
    Rickards, J.
    REVISTA MEXICANA DE FISICA, 2011, 57 (01) : 50 - 54
  • [9] Comparative study of short- and long-term indoor radon measurements
    Al-Jarallah, M. I.
    Fazal-ur-Rehman
    Abdalla, Khalid
    RADIATION MEASUREMENTS, 2008, 43 (SUPPL.1) : S471 - S474
  • [10] PREDICTION OF LONG-TERM INDOOR RADON CONCENTRATION BASED ON SHORT-TERM MEASUREMENTS
    Stojanovska, Zdenka
    Ivanova, Kremena
    Bossew, Peter
    Boev, Blazo
    Zunic, Zora S.
    Tsenova, Martina
    Curguz, Zoran
    Kolarz, Predrag
    Zdravkovska, Milka
    Ristova, Mimoza
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2017, 32 (01): : 77 - 84