Factors Affecting the Longevity and Strength in an In Vitro Model of the Bone–Ligament Interface

被引:0
|
作者
Jennifer Z. Paxton
Kenneth Donnelly
Robert P. Keatch
Keith Baar
Liam M. Grover
机构
[1] University of Dundee,Division of Molecular Physiology
[2] University of Dundee,Division of Mechanical Engineering and Mechatronics
[3] University of Birmingham,School of Chemical Engineering, College of Physical Science and Engineering
[4] University of California,undefined
来源
关键词
Ligament; Enthesis; Regenerative medicine; Brushite;
D O I
暂无
中图分类号
学科分类号
摘要
The interfaces between musculoskeletal tissues with contrasting moduli are morphologically and biochemically adapted to allow the transmission of force with minimal injury. Current methods of tissue engineering ligaments and tendons do not include the interface and this may limit the future clinical success of engineered musculoskeletal tissues. This study aimed to use solid brushite cement anchors to engineer intact ligaments from bone-to-bone, creating a functional musculoskeletal interface in vitro. We show here that modifying anchor shape and cement composition can alter both the longevity and the strength of an in vitro model of the bone–ligament interface: with values reaching 23 days and 21.6 kPa, respectively. These results validate the use of brushite bone cement to engineer the bone–ligament interface in vitro and raise the potential for future use in ligament replacement surgery.
引用
收藏
页码:2155 / 2166
页数:11
相关论文
共 50 条
  • [1] Factors Affecting the Longevity and Strength in an In Vitro Model of the Bone-Ligament Interface
    Paxton, Jennifer Z.
    Donnelly, Kenneth
    Keatch, Robert P.
    Baar, Keith
    Grover, Liam M.
    ANNALS OF BIOMEDICAL ENGINEERING, 2010, 38 (06) : 2155 - 2166
  • [2] Factors affecting the static shear strength of the prosthetic stem–bone cement interface
    Jian-Sheng Wang
    Mark Taylor
    Gunnar Flivik
    Lars Lidgren
    Journal of Materials Science: Materials in Medicine, 2003, 14 : 55 - 61
  • [3] Factors affecting the static shear strength of the prosthetic stem-bone cement interface
    Wang, JS
    Taylor, M
    Flivik, G
    Lidgren, L
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2003, 14 (01) : 55 - 61
  • [4] SHEAR-STRENGTH OF TRABECULAR BONE FROM FEMUR, AND SOME FACTORS AFFECTING SHEAR-STRENGTH OF CEMENT-BONE INTERFACE
    HALAWA, M
    LEE, AJC
    LING, RSM
    VANGALA, SS
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1978, 92 (01) : 19 - 30
  • [5] SOME FACTORS AFFECTING THE STRENGTH OF THE CEMENT METAL INTERFACE
    STONE, MH
    WILKINSON, R
    STOTHER, IG
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1989, 71 (02): : 217 - 221
  • [6] Engineering an In Vitro Model of a Functional Ligament from Bone to Bone
    Paxton, Jennifer Z.
    Grover, Liam M.
    Baar, Keith
    TISSUE ENGINEERING PART A, 2010, 16 (11) : 3515 - 3525
  • [7] Factors affecting bone strength other than osteoporosis
    Chiara Ratti
    Ettore Vulcano
    Gianluca Canton
    Marco Marano
    Luigi Murena
    Paolo Cherubino
    Aging Clinical and Experimental Research, 2013, 25 : 9 - 11
  • [8] Factors affecting the pullout strength of cancellous bone screws
    Chapman, JR
    Harrington, RM
    Lee, KM
    Anderson, PA
    Tencer, AF
    Kowalski, D
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (03): : 391 - 398
  • [9] Factors affecting the pullout strength of cancellous bone screws
    Chapman, J.R.
    Harrington, R.M.
    Lee, K.M.
    Anderson, P.A.
    Tencer, A.F.
    Kowalski, D.
    Journal of Biomechanical Engineering, 1996, 118 (03): : 391 - 398
  • [10] Factors affecting bone strength other than osteoporosis
    Ratti, Chiara
    Vulcano, Ettore
    Canton, Gianluca
    Marano, Marco
    Murena, Luigi
    Cherubino, Paolo
    AGING CLINICAL AND EXPERIMENTAL RESEARCH, 2013, 25 : S9 - S11