Treatment of distal radius fractures with locking plates: an update

被引:11
|
作者
Loisel F. [1 ,2 ,3 ]
Kielwasser H. [1 ,2 ,3 ]
Faivre G. [1 ,2 ,3 ]
Rondot T. [1 ,2 ,3 ]
Rochet S. [1 ,2 ,3 ]
Adam A. [1 ,2 ,3 ]
Sergent P. [1 ,2 ,3 ]
Leclerc G. [1 ,2 ,3 ]
Obert L. [1 ,2 ,3 ]
Lepage D. [1 ,2 ,3 ]
机构
[1] Department of Orthopedic, Trauma, Plastic and Reconstructive Surgery and Hand Clinic, University Hospital Besançon - Medical School CIC IT, 808 - Bd Fleming, Besançon
[2] Research Unit: Nano Médecine, University of Bourgogne - Franche Comté, Besançon
关键词
Dorsal plate; Secondary displacement; Volar plate;
D O I
10.1007/s00590-018-2274-z
中图分类号
学科分类号
摘要
Internal fixation with volar locking plates has revolutionized the treatment of distal radius fractures. Manufacturers have introduced plate designs that closely follow the anatomy of the distal radius. However, use of volar plates has also led to the emergence of new types of complications. While the use of monoaxial or polyaxial locking screws and of minimally invasive techniques (arthroscopy, preservation of pronator quadratus) increases the cost of the surgical procedure, it results in a tangible benefit for patients, allowing them to move their wrist almost immediately after surgery and to quickly regain their autonomy. We reviewed the literature to analyze the level of proof. © 2018, Springer-Verlag France SAS, part of Springer Nature.
引用
收藏
页码:1537 / 1542
页数:5
相关论文
共 50 条
  • [1] Surgical treatment of unstable distal radius fractures with volar locking plates
    Murakami, Kenichi
    Abe, Yoshihiro
    Takahashi, Kazuhisa
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2007, 12 (02) : 134 - 140
  • [2] Treatment of distal radius fractures Percutaneous Kirschner-wires or palmar locking plates?
    Meier, R.
    Krettek, C.
    Probst, C.
    UNFALLCHIRURG, 2012, 115 (07): : 598 - 605
  • [3] Comparative study of treatment for distal radius fractures with two different palmar locking plates
    Tanaka, H.
    Hatta, T.
    Sasajima, K.
    Itoi, E.
    Aizawa, T.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2016, 41 (05) : 536 - 542
  • [4] Comparison between Carbon-Peek volar locking plates and titanium volar locking plates in the treatment of distal radius fractures
    Perugia, Dario
    Guzzini, Matteo
    Mazza, Daniele
    Iorio, Carlo
    Civitenga, Carolina
    Ferretti, Andrea
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 : S24 - S29
  • [5] Complications of volar locking plates used to treat distal radius fractures
    Herzberg, G.
    Marc, A.
    Burnier, M.
    HAND SURGERY & REHABILITATION, 2016, 35 : S95 - S98
  • [6] Complications of distal radius locking plates
    Toros, Tulgar
    Sugun, Tahir Sadik
    Ozaksar, Kemal
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (03): : 336 - 339
  • [7] Treatment of unstable distal radius fractures with the volar locking plate
    Minegishi, Hanae
    Dohi, Osamu
    An, Soukan
    Sato, Hidetsugu
    UPSALA JOURNAL OF MEDICAL SCIENCES, 2011, 116 (04) : 280 - 284
  • [8] Indications for locking plate osteosynthesis in the treatment of distal radius fractures
    Woltmann, A.
    Hierholzer, C.
    Buehren, V
    TRAUMA UND BERUFSKRANKHEIT, 2007, 9 (01) : 6 - 13
  • [9] A Comparison Between Volar Locking Plates and Percutaneous Pinning in the Treatment of Distal Radius Fractures: A Systematic Review
    Gopal, Nikhil
    Anil, Abhijith
    Gopal, Meera
    Bhat, Anil K.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2025, 50 (03): : 265 - 273
  • [10] PALMAR FIXATION OF DORSALLY DISPLACED DISTAL RADIUS FRACTURES USING LOCKING PLATES WITH SMARTLOCK LOCKING SCREWS
    Wong, T. C.
    Yeung, C. C.
    Chiu, Y.
    Yeung, S. H.
    Ip, F. K.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2009, 34E (02) : 173 - 178