Avoiding full corrections in dynamic SPECT images impacts the performance of SPECT myocardial blood flow quantitation

被引:0
|
作者
Lei Wang
Dayong Wu
Yong Yang
Ing-Jou Chen
Chih-Yuan Lin
Bailing Hsu
Wei Fang
Yi-Da Tang
机构
[1] Chinese Academy of Medical Sciences and Peking Union Medical College,Department of Nuclear Medicine, Fu Wai Hospital, National Center for Cardiovascular Diseases
[2] Bailing Cloud Biomedical Technologies Innovation,Department of Medical Physics Research
[3] National Taipei University of Technology,Department of Electro
[4] University of Missouri-Columbia,optical Engineering
[5] Chinese Academy of Medical Sciences and Peking Union Medical College,Nuclear Science and Engineering Institute
来源
关键词
SPECT myocardial blood flow quantitation; dynamic SPECT; physical interference; physical corrections;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:1332 / 1346
页数:14
相关论文
共 50 条
  • [1] Avoiding full corrections in dynamic SPECT images impacts the performance of SPECT myocardial blood flow quantitation
    Wang, Lei
    Wu, Dayong
    Yang, Yong
    Chen, Ing-Jou
    Lin, Chih-Yuan
    Hsu, Bailing
    Fang, Wei
    Tang, Yi-Da
    JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (04) : 1332 - 1346
  • [2] Myocardial blood flow quantitation with the SPECT technique: Is it ready to be a substitute for PET myocardial blood flow quantitation?
    Fang, Wei
    Hsu, Bailing
    JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (06) : 3152 - 3154
  • [3] Myocardial blood flow quantitation with the SPECT technique: Is it ready to be a substitute for PET myocardial blood flow quantitation?
    Wei Fang
    Bailing Hsu
    Journal of Nuclear Cardiology, 2022, 29 : 3152 - 3154
  • [4] Absolute quantitation of regional myocardial blood flow of rats using dynamic pinhole SPECT
    Aoi, T
    Watabe, H
    Deloar, HM
    Ogawa, M
    Teramoto, N
    Kudomi, N
    Oota, T
    Kim, KM
    Matsuda, T
    Iida, H
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1780 - 1783
  • [5] SPECT Myocardial Blood Flow Quantitation Concludes Equivocal Myocardial Perfusion SPECT Studies to Increase Diagnostic Benefits
    Chen, Lung-Ching
    Lin, Chih-Yuan
    Chen, Ing-Jou
    Ku, Chi-Tai
    Chen, Yen-Kung
    Hsu, Bailing
    CLINICAL NUCLEAR MEDICINE, 2016, 41 (01) : e60 - e62
  • [6] SPECT myocardial blood flow quantitation for the detection of angiographic stenoses with cardiac-dedicated CZT SPECT
    Zhang, Jie
    Xie, Jian
    Li, Muwei
    Fang, Wei
    Hsu, Bailing
    JOURNAL OF NUCLEAR CARDIOLOGY, 2023, 30 (06) : 2618 - 2632
  • [7] SPECT myocardial blood flow quantitation for the detection of angiographic stenoses with cardiac-dedicated CZT SPECT
    Jie Zhang
    Jian Xie
    Muwei Li
    Wei Fang
    Bailing Hsu
    Journal of Nuclear Cardiology, 2023, 30 : 2618 - 2632
  • [8] Myocardial Blood Flow Quantitation with Comprehensive Image Corrections: Head-to-Head Comparison between Conventional Dual-head SPECT and CZT SPECT
    Wang, L.
    Wu, D.
    Ma, R.
    Hsu, B.
    Fang, W.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S17 - S17
  • [9] A method to measure the extent of myocardial ischemia and steal with SPECT myocardial blood flow quantitation
    Chen, Lung-Ching
    Hung, Huei-Fong
    Jong, Bor-Hsin
    Lin, Sheng-Che
    Yeh, Chia-lu
    Ku, Chi-Tai
    Chen, Yen-Kung
    Hsu, Bailing
    ANNALS OF NUCLEAR MEDICINE, 2020, 34 (09) : 682 - 690
  • [10] A method to measure the extent of myocardial ischemia and steal with SPECT myocardial blood flow quantitation
    Lung-Ching Chen
    Huei-Fong Hung
    Bor-Hsin Jong
    Sheng-Che Lin
    Chia-lu Yeh
    Chi-Tai Ku
    Yen-Kung Chen
    Bailing Hsu
    Annals of Nuclear Medicine, 2020, 34 : 682 - 690