A method of reducing susceptibility artifacts in MRI of the head and neck region

被引:3
|
作者
Minowa K. [1 ]
Abe S. [1 ]
Sawamura T. [1 ]
Obinata K. [1 ]
Ohmori K. [1 ]
Nakamura M. [1 ]
机构
[1] Department of Dental Radiology, Hokkaido Univ. School of Dentistry, Kita-ku, Sapporo 060, Nishi 7-chome
关键词
Head and neck region; Mid; Susceptibility artifact;
D O I
10.1007/BF02489642
中图分类号
学科分类号
摘要
Methods of reducing susceptibility artifacts, which invariably occur in MRI examinations of the head and neck region, were investigated in healthy subjects and in patients with head and neck disease. It was found that MRI examination of the head and neck region can be improved by setting the read- out direction in the axial cross-sectional image in the anteroposterior direction and by making TE as small as possible.
引用
收藏
页码:45 / 49
页数:4
相关论文
共 50 条
  • [1] MR Imaging Artifacts in the Head and Neck Region Pitfalls and Solutions
    Marshall, Emily L.
    Ginat, Daniel T.
    Sammet, Steffen
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2022, 32 (02) : 279 - 286
  • [2] Computed Tomography Imaging Artifacts in the Head and Neck Region Pitfalls and Solutions
    Marshall, Emily L.
    Ginat, Daniel T.
    Sammet, Steffen
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2022, 32 (02) : 271 - 277
  • [3] Indications for and accuracy of CT and MRI in the head and neck region
    Greess, H
    Lell, M
    Römer, W
    Bautz, W
    HNO, 2002, 50 (07) : 611 - 625
  • [4] Gradient compensated reverse spiral acquisition for reducing susceptibility artifacts in functional MRI
    Stenger, VA
    Yang, Q
    Boada, F
    Noll, D
    NEUROIMAGE, 2001, 13 (06) : S43 - S43
  • [5] An optimized and highly repeatable MRI acquisition and processing pipeline for quantitative susceptibility mapping in the head-and-neck region
    Karsa, Anita
    Punwani, Shonit
    Shmueli, Karin
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (06) : 3206 - 3222
  • [6] MRI findings of solitary fibrous tumours in the head and neck region
    Liu, Y.
    Tao, X.
    Shi, H.
    Li, K.
    DENTOMAXILLOFACIAL RADIOLOGY, 2014, 43 (03)
  • [7] MRI OF THE HEAD AND NECK
    LUFKIN, R
    HANAFEE, W
    MAGNETIC RESONANCE IMAGING, 1988, 6 (01) : 69 - 88
  • [8] Simultaneous Z-Shim Method for Reducing Susceptibility Artifacts With Multiple Transmitters
    Deng, Weiran
    Yang, Cungeng
    Alagappan, Vijayanand
    Wald, Lawrence L.
    Boada, Fernando E.
    Stenger, V. Andrew
    MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (02) : 255 - 259
  • [9] The Principal of Dynamic Contrast Enhanced MRI, the Method of Pharmacokinetic Analysis, and Its Application in the Head and Neck Region
    Chikui, Toru
    Ohara, Makoto
    Simonetti, Arjan W.
    Ohga, Masahiro
    Koga, Shoichi
    Kawano, Shintaro
    Matsuo, Yoshio
    Kamintani, Takeshi
    Shiraishi, Tomoko
    Kitamoto, Erina
    Nakamura, Katsumasa
    Yoshiural, Kazunori
    INTERNATIONAL JOURNAL OF DENTISTRY, 2012, 2012
  • [10] Reducing Streaking Artifacts in Quantitative Susceptibility Mapping
    Palacios, Benjamin
    Uhlmann, Gunther
    Wang, Yiran
    SIAM JOURNAL ON IMAGING SCIENCES, 2017, 10 (04): : 1921 - 1934