Securing accuracy and precision when pipetting hot and cold liquids with Microman®

被引:0
|
作者
Frédéric Millet
Thierry Barthlen
机构
[1] Gilson S.A.S.,
来源
Nature Methods | 2007年 / 4卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Biotechnology researchers and laboratory technicians cannot always prevent errors in their results owing to the temperature variation between samples and pipettes. Gilson, the pioneer in high-quality pipetting technology, has developed a positive displacement pipette, the Microman®, to circumvent the issue. Here we present a comparison of Microman® performance with that of the Pipetman®, the reliability standard from Gilson.
引用
收藏
页码:iii / iv
相关论文
共 50 条
  • [1] Securing accuracy and precision when pipetting hot and cold liquids with Microman®
    Millet, Frederic
    Barthlen, Thierry
    NATURE METHODS, 2007, 4 (09) : III - IV
  • [2] Errors associated with pipetting of warm and cold liquids
    Smith, J.
    Davis, A.
    Rodrigues, G.
    CLINICAL CHEMISTRY, 2007, 53 (06) : A119 - A119
  • [3] THE ACCURACY, PRECISION, AND UTILITY OF THE SYRINGE AS A PIPETTING DEVICE
    DERN, RJ
    PULLMAN, TN
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1950, 36 (03): : 494 - 500
  • [4] Increasing Precision When Pipetting Protein Samples: Assessing Reliability of the Reverse Pipetting Technique
    Suominen, Irmgard
    Koivisto, Sami
    AMERICAN LABORATORY, 2011, 43 (02) : 50 - 52
  • [5] EVALUATION OF PIPETTING DEVICES .2. PRECISION AND ACCURACY OF DISPENSERS
    LORIA, A
    SALAS, R
    REVISTA DE INVESTIGACION CLINICA-CLINICAL AND TRANSLATIONAL INVESTIGATION, 1990, 42 (02): : 157 - 160
  • [6] Automated Optic Calibration to Optimize Pipetting Accuracy and Precision in a Liquid Handling System
    Bach, Anna
    Mikkat, Sebastian
    Fleischer, Heidi
    Tlili, Mohamed Ali
    Roddelkopf, Thomas
    Thurow, Kerstin
    2024 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, I2MTC 2024, 2024,
  • [7] When cold becomes hot
    McNulty, Penelope A.
    Burke, David
    JOURNAL OF PHYSIOLOGY-LONDON, 2009, 587 (23): : 5511 - 5511
  • [8] Precision and accuracy of cold fusion calorimetry
    Miles, Melvin H.
    Fleischmann, Martin
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2007, 233 : 356 - 356
  • [9] TEMPERATURE EXTREMES PRODUCED ORALLY BY HOT AND COLD LIQUIDS
    PALMER, DS
    BARCO, MT
    BILLY, EJ
    JOURNAL OF PROSTHETIC DENTISTRY, 1992, 67 (03): : 325 - 327
  • [10] When hot water freezes before cold
    Katz, J. I.