Feasibility of stress only rubidium-82 PET myocardial perfusion imaging

被引:0
|
作者
Sean R. McMahon
Janusz Kikut
Richard G. Pinckney
Friederike K. Keating
机构
[1] University of Vermont,Department of Medicine, Fletcher Allen Health Care
[2] University of Vermont,Department of Nuclear Medicine and Diagnostic Radiology
[3] University of Vermont,Center for Clinical and Translational Science and Department of Medicine
[4] University of Vermont,Division of Cardiology, Department of Medicine
来源
关键词
Myocardial perfusion imaging; PET; stress only; radiation reduction;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:1069 / 1075
页数:6
相关论文
共 50 条
  • [1] Feasibility of stress only rubidium-82 PET myocardial perfusion imaging
    McMahon, Sean R.
    Kikut, Janusz
    Pinckney, Richard G.
    Keating, Friederike K.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2013, 20 (06) : 1069 - 1075
  • [2] FEASIBILITY OF STRESS-ONLY RUBIDIUM-82 PET MYOCARDIAL PERFUSION IMAGING TO REDUCE RADIATION EXPOSURE
    McMahon, Sean Robert
    Kikut, Janusz
    Pinckney, Richard
    Keating, Friederike
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E1320 - E1320
  • [3] Story of rubidium-82 and advantages for myocardial perfusion PET imaging
    Chatal, Jean-Francois
    Rouzet, Francois
    Haddad, Fend
    Bourdeau, Cecile
    Mathieu, Cedric
    Le Guludec, Dominique
    FRONTIERS IN MEDICINE, 2015, 2
  • [4] Reproducibility of absolute myocardial perfusion measurements with rubidium-82 PET imaging
    Beauchesne, LM
    Ruddy, TD
    deKemp, RA
    Aung, MT
    Levesque, N
    Alvarez-Diaz, T
    Vickers, TK
    Aubrey, BA
    Beanlands, RSB
    CIRCULATION, 1998, 98 (17) : 222 - 222
  • [5] Value of SiPM PET in myocardial perfusion imaging using Rubidium-82
    Koenders, S. S.
    van Dalen, J. A.
    Jager, P. L.
    Knollema, S.
    Timmer, J. R.
    Mouden, M.
    Slump, H.
    van Dijk, J. D.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (01) : 204 - 212
  • [6] Value of Digital PET in Myocardial Perfusion Imaging Using Rubidium-82 PET
    Koenders, S. S.
    van Dalen, J. A.
    Jager, P. L.
    Knollema, S.
    Timmer, J. R.
    Slump, C. H.
    van Dijk, J. D.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S19 - S19
  • [7] Rubidium-82 tracer activity optimisation for PET myocardial perfusion imaging
    Huizing, E. D.
    van Dijk, J. D.
    van Dalen, J. A.
    Timmer, J. R.
    Arkies, H.
    Slump, C. H.
    Jager, P. L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S248 - S248
  • [8] Value of SiPM PET in myocardial perfusion imaging using Rubidium-82
    S. S. Koenders
    J. A. van Dalen
    P. L. Jager
    S. Knollema
    J. R. Timmer
    M. Mouden
    C. H. Slump
    J. D. van Dijk
    Journal of Nuclear Cardiology, 2022, 29 : 204 - 212
  • [9] Reproducibility of total perfusion deficit measurements for rubidium-82 PET myocardial perfusion imaging
    Renaud, Jennifer
    Beanlands, Rob
    deKemp, Robert
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [10] Minimizing rubidium-82 tracer activity for relative PET myocardial perfusion imaging
    Huizing, Eline D.
    van Dijk, Joris D.
    van Dalen, Jorn A.
    Timmer, Jorik R.
    Arkies, Hester
    Slump, Cees H.
    Jager, Pieter L.
    NUCLEAR MEDICINE COMMUNICATIONS, 2017, 38 (08) : 708 - 714