Numerical mass balances for cross flow membrane contactors and their approximations

被引:0
|
作者
Sung Bin Park
Jung Woo Lee
Yong Soo Kim
Chul Soo Lee
机构
[1] Korea University,Department of Chemical and Biological Engineering
来源
关键词
Membrane Contactor; Cross Flow; Mass Transfer Coefficient; Mass Balance;
D O I
暂无
中图分类号
学科分类号
摘要
Membrane contactor processes for stripping of sparingly soluble components such as oxygen are well understood. For readily soluble components in cross flow hollow fiber membrane modules, however, mass balances are less well established. In the present study, numerical and analytical solutions for cross flow modules are presented and compared with hitherto used solutions. Based on the comparison the best approximate solution is proposed.
引用
收藏
页码:479 / 482
页数:3
相关论文
共 50 条
  • [1] Numerical mass balances for cross flow membrane contactors and their approximations
    Park, SB
    Lee, JW
    Kim, YS
    Lee, CS
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2005, 22 (03) : 479 - 482
  • [2] Modelling of cross-flow membrane contactors: physical mass transfer processes
    Dindore, VY
    Brilman, DWF
    Versteeg, GF
    JOURNAL OF MEMBRANE SCIENCE, 2005, 251 (1-2) : 209 - 222
  • [3] Modelling of cross-flow membrane contactors: Mass transfer with chemical reactions
    Dindore, VY
    Brilman, DWF
    Versteeg, GE
    JOURNAL OF MEMBRANE SCIENCE, 2005, 255 (1-2) : 275 - 289
  • [4] DESIGNING OF MEMBRANE CONTACTORS WITH CROSS-COUNTER CURRENT FLOW
    Koltuniewicz, Andrzej B.
    Modelski, Szymon
    Witek, Anna
    CHEMICAL AND PROCESS ENGINEERING-INZYNIERIA CHEMICZNA I PROCESOWA, 2012, 33 (04): : 573 - 583
  • [5] Numerical simulation of mass transfer in gas-liquid hollow fiber membrane contactors for laminar flow conditions
    Shirazian, Saeed
    Moghadassi, Abdolreza
    Moradi, Sadegh
    SIMULATION MODELLING PRACTICE AND THEORY, 2009, 17 (04) : 708 - 718
  • [6] Performance characteristics of cross-flow membrane contactors for liquid desiccant systems
    Das, Rajat Subhra
    Jain, Sanjeev
    APPLIED ENERGY, 2015, 141 : 1 - 11
  • [7] Reconciliation of gas to liquid mass transfer in parallel and transverse flow (cross-flow) hollow fiber membrane contactors (HFMC) for CO2 absorption
    Houlker, S.
    Davey, C. J.
    Allemand, A.
    Brookes, A.
    Moore, A.
    Vale, P.
    Pidou, M.
    McAdam, E. J.
    SEPARATION SCIENCE AND TECHNOLOGY, 2021, 56 (01) : 129 - 140
  • [8] Gas-liquid absorption in industrial cross-flow membrane contactors: Experimental and numerical investigation of the influence of transmembrane pressure on partial wetting
    Fougerit, Valentin
    Pozzobon, Victor
    Pareau, Dominique
    Theoleyre, Marc-Andre
    Stambouli, Moncef
    CHEMICAL ENGINEERING SCIENCE, 2017, 170 : 561 - 573
  • [9] Fluid flow and heat transfer of cross flow hollow fiber membrane contactors with randomly distributed fibers: A topological study
    He, Kui
    Zhang, Li-Zhi
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 135 : 186 - 198
  • [10] Two-Dimensional Numerical Analysis of Membrane-Based Heat and Mass Cross-Flow Exchanger
    Ja, Marip Kum
    Choo, Fook Hoong
    Li, Bing
    Chakraborty, Anutosh
    Dass, Ettanoor T. Mohan
    Zhao, Kui
    Dubey, Swapnil
    HEAT TRANSFER ENGINEERING, 2017, 38 (04) : 438 - 445