Errors in the Extra-Analytical Phases of Clinical Chemistry Laboratory Testing

被引:11
|
作者
Zemlin A.E. [1 ]
机构
[1] Division of Chemical Pathology, National Health Laboratory Service (NHLS) and University of Stellenbosch, Tygerberg Hospital, Cape Town
关键词
Laboratory errors; Postanalytical phase; Preanalytical phase; Quality assessment; Quality indicators;
D O I
10.1007/s12291-017-0657-2
中图分类号
学科分类号
摘要
The total testing process consists of various phases from the pre-preanalytical to the post-postanalytical phase, the so-called brain-to-brain loop. With improvements in analytical techniques and efficient quality control programmes, most laboratory errors now occur in the extra-analytical phases. There has been recent interest in these errors with numerous publications highlighting their effect on service delivery, patient care and cost. This interest has led to the formation of various working groups whose mission is to develop standardized quality indicators which can be used to measure the performance of service of these phases. This will eventually lead to the development of external quality assessment schemes to monitor these phases in agreement with ISO15189:2012 recommendations. This review focuses on potential errors in the extra-analytical phases of clinical chemistry laboratory testing, some of the studies performed to assess the severity and impact of these errors and processes that are in place to address these errors. The aim of this review is to highlight the importance of these errors for the requesting clinician. © 2017, Association of Clinical Biochemists of India.
引用
收藏
页码:154 / 162
页数:8
相关论文
共 50 条
  • [1] Performance specifications for the extra-analytical phases of laboratory testing: Why and how
    Plebani, Mario
    CLINICAL BIOCHEMISTRY, 2017, 50 (10-11) : 550 - 554
  • [2] Quality indicators and specifications for the extra-analytical phases in clinical laboratory management
    Ricós, C
    García-Victoria, M
    de la Fuente, B
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2004, 42 (06) : 578 - 582
  • [3] Prevention of extra-analytical phase errors by non-analytical automation in clinical laboratory
    Bakan, Ebubekir
    Bakan, Nuri
    TURKISH JOURNAL OF BIOCHEMISTRY-TURK BIYOKIMYA DERGISI, 2021, 46 (03): : 235 - 243
  • [4] Automation of extra-analytical phase for clinical laboratory
    Bakan, Ebubekir
    Umudum, Fatma Zuhal
    TURKISH JOURNAL OF BIOCHEMISTRY-TURK BIYOKIMYA DERGISI, 2021, 46 (02): : 115 - 128
  • [5] Towards quality specifications in extra-analytical phases of laboratory activity
    Plebani, M
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2004, 42 (06) : 576 - 577
  • [6] Quality in the extra-analytical phases of urinalysis
    Caleffi, Alberta
    Manoni, Fabio
    Alessio, Maria Grazia
    Ottomano, Cosimo
    Lippi, Giuseppe
    BIOCHEMIA MEDICA, 2010, 20 (02) : 179 - 183
  • [7] The Impact of COVID-19 Containment Actions on Extra-Analytical Phases of the Clinical Laboratory: A Case Report
    Mahto, Mala
    Kumar, Mukunda
    Banerjee, Ayan
    Kumar, Sushil
    LABORATORY MEDICINE, 2021, 52 (06) : 619 - 625
  • [8] Extra-analytical quality indicators and laboratory performances
    Sciacovelli, Laura
    Aita, Ada
    Plebani, Mario
    CLINICAL BIOCHEMISTRY, 2017, 50 (10-11) : 632 - 637
  • [9] Performance specifications in extra-analytical phase of laboratory testing: Sample handling and transportation
    Zaninotto, Martina
    Tasinato, Adriano
    Vecchiato, Gianni
    Legnaro, Angelo
    Pinato, Alessio
    Plebani, Mario
    CLINICAL BIOCHEMISTRY, 2017, 50 (10-11) : 574 - 578
  • [10] Quality improvement in laboratory medicine: Extra-analytical issues
    Lippi, Giuseppe
    Fostini, Roberto
    Guidi, Gian Cesare
    CLINICS IN LABORATORY MEDICINE, 2008, 28 (02) : 285 - +