Experimental Study on Paschen Discharge in Helium for High Voltage Cryogenic Insulation Material

被引:0
|
作者
Zheng Jinxing
Song Yuntao
Chunlong Zhou
Huang Xiongyi
Lu Kun
Wang Jun
Ding Kaizhong
Zhu Haisheng
机构
[1] Chinese Academy of Sciences,Institute of Plasma Physics
来源
Journal of Fusion Energy | 2014年 / 33卷
关键词
Paschen; High voltage; Insulation; Superconducting;
D O I
暂无
中图分类号
学科分类号
摘要
According to the requirements of large superconducting components, all the solid superconducting insulation of current leads, magnets, cooling and measurement pipeline at high potential should withstand 80–300 K thermal cycles. If helium leak or pipe leak taken place, and insulation has been formed some flaws, Paschen discharge would be occur. The experimental program aimed at analyzing the low-temperature electro-physical performance of solid superconducting insulation, which was designed with different configuration such as thickness, material structure and so on. The dielectric performance of both pre-preg cryogenic insulation and the wet wrap cryogenic insulation were studied. Both of the dielectric strength of the two type insulation is in the range from 11 to 23 kV/mm at 80 K helium condition. Besides, both of the two type insulation samples of 3 and 5 mm thickness can withstand 30 kV under various helium pressures at 80 K.
引用
收藏
页码:594 / 599
页数:5
相关论文
共 50 条
  • [1] Experimental Study on Paschen Discharge in Helium for High Voltage Cryogenic Insulation Material
    Zheng Jinxing
    Song Yuntao
    Chunlong Zhou
    Huang Xiongyi
    Lu Kun
    Wang Jun
    Ding Kaizhong
    Zhu Haisheng
    JOURNAL OF FUSION ENERGY, 2014, 33 (05) : 594 - 599
  • [2] Experimental Study on the Barrier Effects in Gaseous Helium for the Insulation Design of a High Voltage SFCL
    Kang, Hyoungku
    Na, Jin Bae
    Chung, Yoon Do
    Ko, Tae Kuk
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (03) : 1328 - 1331
  • [3] Experimental study on cryogenic moisture uptake in polyurethane foam insulation material
    Zhang, X. B.
    Yao, L.
    Qiu, L. M.
    Gan, Z. H.
    Yang, R. P.
    Ma, X. J.
    Liu, Z. H.
    CRYOGENICS, 2012, 52 (12) : 810 - 815
  • [4] Cryogenic high voltage insulation breaks for ITER
    Kovalchuk, O. A.
    Safonov, A. V.
    Rodin, I. Yu.
    Mednikov, A. A.
    Lancetov, A. A.
    Klimchenko, Yu. A.
    Grinchenko, V. A.
    Voronin, N. M.
    Smorodina, N. V.
    Bursikov, A. S.
    PROCEEDINGS OF THE 25TH INTERNATIONAL CRYOGENIC ENGINEERING CONFERENCE AND INTERNATIONAL CRYOGENIC MATERIALS CONFERENCE 2014, 2015, 67 : 698 - 704
  • [5] Experimental Study on Paschen Tests of ITER Current Lead Insulation
    郑金星
    宋云涛
    黄雄一
    陆坤
    奚维斌
    丁开忠
    叶斌
    牛二武
    Plasma Science and Technology, 2013, 15 (02) : 152 - 156
  • [6] Experimental Study on Paschen Tests of ITER Current Lead Insulation
    郑金星
    宋云涛
    黄雄一
    陆坤
    奚维斌
    丁开忠
    叶斌
    牛二武
    Plasma Science and Technology, 2013, (02) : 152 - 156
  • [7] Experimental Study on Paschen Tests of ITER Current Lead Insulation
    Zheng Jinxing
    Song Yuntao
    Huang Xiongyi
    Lu Kun
    Xi Weibin
    Ding Kaizhon
    Ye Bin
    Niu Erwu
    PLASMA SCIENCE & TECHNOLOGY, 2013, 15 (02) : 152 - 156
  • [8] Partial Discharge Patterns in High Voltage Insulation
    Illias, Hazlee
    Yuan, Teo Soon
    Abu Bakar, Ab Halim
    Mokhlis, Hazlie
    Chen, George
    Lewin, Paul L.
    2012 IEEE INTERNATIONAL CONFERENCE ON POWER AND ENERGY (PECON), 2012, : 750 - 755
  • [9] 30 kV, 40 kA cryogenic current leads and high voltage insulation breaks for helium lines of superconducting magnets
    Glukhikh, VA
    Egorov, SA
    Filatov, OG
    Korsunsky, VE
    Lamzin, EA
    Sychevsky, SE
    Weber, CM
    Batchelder, RR
    Dixon, KD
    Karasik, VR
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2000, 10 (01) : 1477 - 1480
  • [10] Novel Cryogenic High Voltage Insulation Breaks With Spiral Channel.
    Bursikov, A. S.
    Voronin, N. M.
    Gavrilov, S. M.
    Grinchenko, V. A.
    Klimchenko, Yu. A.
    Korsunskiy, V. A.
    Kovalchuk, O. A.
    Lancetov, A. A.
    Marushin, E. L.
    Mednikov, A. A.
    Rodin, I. Yu.
    Safonov, A. V.
    ADVANCES IN CRYOGENIC ENGINEERING, 2014, 1573 : 1700 - 1706