Behavior of a Nuclear Power Plant Ventilation Stack for Wind Loads

被引:0
|
作者
Venkatachalapathy V. [1 ]
机构
[1] Civil Engineering Group, Indira Gandhi Centre for Atomic Research, Kalpakkam
关键词
Along and across wind loads; Engineered backfill soil; Ventilation stack/chimney;
D O I
10.1007/s40030-012-0015-6
中图分类号
学科分类号
摘要
This paper describes behavior of self supporting tall reinforced concrete (RC) ventilation stack of a nuclear power plant (NPP) for wind loads. Since the static and equivalent dynamic wind loads are inter-dependant on overall size of the stack, proper sizing of the stack geometry is important for reducing wind loads. The present study investigated the influence of engineered backfill soil on lateral response of ventilation stack. Ignoring backfill soil stiffness up to ground height does not allow to predict actual critical wind velocity causing across wind oscillation. The results show that proposed modification in the stack geometry modeled using 2D beam-spring elements is economical than that of single tapered geometry. Shaft diameter reduced in the proposed geometry indicates that there is a scope for overall space savings in the NPP layout. © 2012, The Institution of Engineers (India).
引用
收藏
页码:143 / 149
页数:6
相关论文
共 50 条
  • [1] Effect of wind on stack ventilation performance
    Gladyszewska-Fiedoruk, Katarzyna
    Gajewski, Andrzej
    ENERGY AND BUILDINGS, 2012, 51 : 242 - 247
  • [2] Optimum seismic design of ventilation fan for nuclear power plant
    Ik-Su Jang
    Eun-Ho Choi
    Jin-Rae Cho
    Kwon Son
    O-Kaung Lim
    Journal of Mechanical Science and Technology, 2015, 29 : 1437 - 1442
  • [3] Optimum seismic design of ventilation fan for nuclear power plant
    Jang, Ik-Su
    Choi, Eun-Ho
    Cho, Jin-Rae
    Son, Kwon
    Lim, O-Kaung
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2015, 29 (04) : 1437 - 1442
  • [4] End to end navigation stack for nuclear power plant inspection with mobile robot
    Bedkowski, Janusz
    SOFTWAREX, 2024, 26
  • [5] Radioxenon Releases from A Nuclear Power Plant: Stack Data and Atmospheric Measurements
    Ringbom, A.
    Axelsson, A.
    Bjornham, O.
    Brannstrom, N.
    Fritioff, T.
    Grahn, H.
    Hennigor, S.
    Olsson, M.
    PURE AND APPLIED GEOPHYSICS, 2021, 178 (07) : 2677 - 2693
  • [6] Radioxenon Releases from A Nuclear Power Plant: Stack Data and Atmospheric Measurements
    A. Ringbom
    A. Axelsson
    O. Björnham
    N. Brännström
    T. Fritioff
    H. Grahn
    S. Hennigor
    M. Olsson
    Pure and Applied Geophysics, 2021, 178 : 2677 - 2693
  • [7] Evaluation of the power system reliability if a nuclear power plant is replaced with wind power plants
    Cepin, Marko
    RELIABILITY ENGINEERING & SYSTEM SAFETY, 2019, 185 : 455 - 464
  • [8] RADIOACTIVE AEROSOLS IN VENTILATION SYSTEMS OF THE CHERNOBYLSK NUCLEAR-POWER PLANT
    CHERNYI, SS
    GRIGOROV, VP
    SOVIET ATOMIC ENERGY, 1982, 53 (05): : 805 - 806
  • [9] SUMMARY OF NUCLEAR BEHAVIOR OF PM-3A NUCLEAR POWER PLANT
    SCARBORO.JC
    BOENNIGH.TL
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1965, 8 (01): : 101 - &
  • [10] UNDERSTANDING WIND LOADS ON PLANT BUILDINGS
    LIU, H
    PLANT ENGINEERING, 1979, 33 (12) : 187 - 191