Evaluation of the position of the central venous catheter tip of implantable venous access devices in the occurrence of postoperative thrombotic and non-thrombotic complications

被引:0
|
作者
Hamri, Hicham [1 ]
Pop, C. Florin [1 ]
Mauriac, Sybil [2 ]
Degreve, Caroline [1 ]
Khaled, Charif [1 ]
Vouche, Michael [3 ]
Moreau, Michel [4 ]
Liberale, Gabriel [1 ]
机构
[1] Univ Libre Bruxelles, Inst Jules Bordet, Dept Surg, HUB, 90 Rue Meylemeersch, B-1070 Brussels, Belgium
[2] HUB, Inst Jules Bordet, Dept Nursing, Brussels, Belgium
[3] Univ Libre Bruxelles ULB, Inst Jules Bordet, Dept Radiol, Brussels, Belgium
[4] Univ Libre Bruxelles, Inst Jules Bordet, Data Ctr & Stat, HUB, Brussels, Belgium
关键词
TIVAD; Cancer therapy; Catheter tip position; Carina; Right main bronchus; Fluoroscopy; INSERTION DEPTH; RISK-FACTORS; PORTS; PREDICTION; LANDMARK; FORMULA; PATIENT;
D O I
10.1007/s00520-024-08563-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background The position of the catheter tip of totally implantable venous access devices (TIVAD) is a risk factor for postoperative complications. The study aim was to assess the early and late complications (EC and LC) associated with the position of the catheter tip in cancer patients. Methods We reviewed cancer patients who had a TIVAD placed in 2020. EC (<= 90 days), LC (> 90 days) and risk factors for TIVAD-associated complications were assessed. The vertical mismatch of the catheter tip was compared to an "ideal position" (> 10 mm below the carina and >= 20 mm below the right main bronchus (RMB)) using chest x-ray, post-implantation. Results 301 patients were included. Median follow-up after TIVAD implantation was 9.4 months. All TIVAD catheters were inserted via the internal jugular vein (IJV). The mean distance between the catheter tip and the carina and the RMB was 21.3 mm and 6.63 mm respectively. In total, 11.3% patients developed EC and 5.6% had LC. An association was found between the position of the catheter tip from the carina (<= 10 mm vs. > 10 mm) and the occurrence of EC (18.3% vs. 8.6%, p = 0.01) and for the catheter insertion side (left IJV vs. right IJV) (19.1% vs. 9.0% p = 0.02). Multivariate analysis showed that left IJV catheter insertion (OR 2.76), and a catheter tip located <= 10 mm below the carina (OR 2.71) are significant independent risk factors of EC. Conclusions TIVAD catheter tip located at <= 10 mm below the carina, and a left-side inserted catheter, are higher risk of EC.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Thrombotic complications of implanted central venous access devices: prospective evaluation
    Labourey, JL
    Lacroix, P
    Genet, D
    Gobeaux, F
    Martin, J
    Venat-Bouvet, L
    Lavau-Denes, S
    Maubon, A
    Tubiana-Mathieu, N
    BULLETIN DU CANCER, 2004, 91 (05) : 431 - 436
  • [2] Thrombotic complications of a femoral central venous catheter
    Desmond, J
    EMERGENCY MEDICINE JOURNAL, 2004, 21 (06) : 714 - 715
  • [3] THROMBOTIC COMPLICATIONS OF CENTRAL VENOUS CATHETERS
    HAIDVOGL, M
    MUTZ, I
    MESSNER, H
    WENDLER, H
    ZEITSCHRIFT FUR KINDERCHIRURGIE UND GRENZGEBIETE, 1974, 15 (01): : 1 - 9
  • [4] ATYPICAL THROMBOTIC AND SEPTIC COMPLICATIONS OF TOTALLY IMPLANTABLE VENOUS ACCESS DEVICES IN PATIENTS WITH CYSTIC-FIBROSIS
    SOLA, JE
    STONE, MM
    WISE, B
    COLOMBANI, PM
    PEDIATRIC PULMONOLOGY, 1992, 14 (04) : 239 - 242
  • [5] Thrombotic complications of central venous catheters in children
    Journeycake, JM
    Buchanan, GR
    CURRENT OPINION IN HEMATOLOGY, 2003, 10 (05) : 369 - 374
  • [6] THROMBOTIC COMPLICATIONS OF SAPHENOUS CENTRAL VENOUS LINES
    PIPPUS, KG
    GIACOMANTONIO, JM
    GILLIS, DA
    REES, EP
    JOURNAL OF PEDIATRIC SURGERY, 1994, 29 (09) : 1218 - 1219
  • [7] Risk Factors for Central Venous Catheter Thrombotic Complications in Children and Adolescents With Cancer
    Revel-Vilk, S.
    Yacobovich, J.
    Tamary, H.
    Goldstein, G.
    Nemet, S.
    Weintraub, M.
    Paltiel, O.
    Kenet, G.
    CANCER, 2010, 116 (17) : 4197 - 4205
  • [8] CENTRAL VENOUS CATHETERS AND THROMBOTIC COMPLICATIONS - A COMPARISON OF 3 DIFFERENT CATHETER MATERIALS
    LINDBLAD, B
    EFSING, HO
    MARK, J
    WOLFF, T
    THROMBOSIS AND HAEMOSTASIS, 1981, 46 (01) : 318 - 318
  • [9] Impact of thrombotic complication on central venous catheter function
    Venslauskaite, D.
    Staponaviciene, V.
    Rascon, J.
    Stankeviciene, S.
    Rageliene, L.
    BONE MARROW TRANSPLANTATION, 2013, 48 : S492 - S492
  • [10] Thrombotic complications of central venous catheters in cancer patients
    Kuter, DJ