Assessment of the efficiency of different chemical treatments and ultrasonic cleaning for defatting of cancellous bone samples

被引:0
|
作者
Fangxing Wang
Florian Metzner
Georg Osterhoff
Stefan Schleifenbaum
机构
[1] Leipzig University,ZESBO
[2] Leipzig University, Center for Research on Musculoskeletal Systems, Department of Orthopaedic Surgery, Traumatology and Plastic Surgery
来源
Cell and Tissue Banking | 2022年 / 23卷
关键词
Defatting; Cancellous bone; Trabecular bone; Bone marrow; Ultrasonic cleaning; Chemical treatments;
D O I
暂无
中图分类号
学科分类号
摘要
Our study aimed to asses the defatting efficiency of different methods, which are commonly used and easily available in the laboratory in order to find a method that is effective, convenient, safe, and economical. Cylindrical cancellous bone specimens were obtained from fresh-frozen human cadaver femoral condyles, cut into multiple small specimens (Ø8 × 2 mm), and assigned to two groups that were treated with either chemical solvent soaking (Solvent group) or ultrasonic cleaning (Ultrasound group). Each group was divided into several subgroups based on different treatments. Digital photographs were taken of each specimen. The difference of material density (Δρb), apparent density (Δρapp), and porosity (ΔP) before and after treatment were used as evaluation indicators. For the solvent group, in Δρb, only the combination of 99% ethanol and detergent solution showed a significant difference before and after treatment (P = 0.00). There was no significant difference in ΔP among acetone, the mixture of 99% ethanol and acetone, and the combination of 99% ethanol and detergent solution (P = 0.93). For the ultrasound group, the median of all subgroups in Δρapp and ΔP were all lower than the solvent group. The combination of 99% ethanol and detergent solution (v/v = 1:20), as well as the mixture of 99% ethanol and acetone (v/v = 1:1), seem to be the optimal defatting methods for 2 mm thick cancellous bone slices due to their effectiveness, availability, low-cost and safety. Chemical soaking for 24 h is more effective than ultrasonic cleaning with 99% ethanol or acetone for 20 or 40 min.
引用
收藏
页码:499 / 510
页数:11
相关论文
共 31 条
  • [1] Assessment of the efficiency of different chemical treatments and ultrasonic cleaning for defatting of cancellous bone samples
    Wang, Fangxing
    Metzner, Florian
    Osterhoff, Georg
    Schleifenbaum, Stefan
    CELL AND TISSUE BANKING, 2022, 23 (03) : 499 - 510
  • [2] ASSESSMENT OF THE EFFICIENCY OF DIFFERENT CHEMICAL TREATMENTS AND ULTRASONIC CLEANING FOR DEFATTING OF CANCELLOUS BONE SAMPLES
    Wang, F.
    Metzner, F.
    Osterhoff, G.
    Schleifenbaum, S.
    AGING CLINICAL AND EXPERIMENTAL RESEARCH, 2023, 35 : S145 - S145
  • [3] Assessment of the Defatting Efficacy of Mechanical and Chemical Treatment for Allograft Cancellous Bone and Its Effects on Biomechanics Properties of Bone
    Hua, Kun-chi
    Feng, Jiang-tao
    Yang, Xiong-gang
    Wang, Feng
    Zhang, Hao
    Yang, Li
    Zhang, Hao-ran
    Xu, Ming-you
    Li, Ji-kai
    Qiao, Rui-qi
    Lun, Deng-xing
    Hu, Yong-cheng
    ORTHOPAEDIC SURGERY, 2020, 12 (02) : 617 - 630
  • [4] Influence of signal selection on ultrasonic backscatter and in cancellous bone assessment
    Liu, Chengcheng
    Tang, Tao
    Ta, Dean
    Wang, Weiqi
    Hu, Bo
    Ta, Dean
    2015 6TH EUROPEAN SYMPOSIUM ON ULTRASONIC CHARACTERIZATION OF BONE (ESUCB), 2015,
  • [5] Assessment of Efficiency and Anilox-Roll Condition after Ultrasonic Cleaning
    Przybysz, Kamila
    Lipkiewicz, Aneta
    Malachowska, Edyta
    Dubowik, Marcin
    Przybysz, Piotr
    COATINGS, 2023, 13 (10)
  • [6] Ultrasonic Bone Assessment: Ability of Apparent Backscatter Techniques to Detect Changes in the Microstructure of Human Cancellous Bone
    Viano, Ann M.
    Ankersen, Jordan P.
    Hoffmeister, Brent K.
    Huang, Jinsong
    Fairbanks, Luke C.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (11) : 3309 - 3325
  • [7] A CONTACT METHOD FOR THE ASSESSMENT OF ULTRASONIC VELOCITY AND BROAD-BAND ATTENUATION IN CORTICAL AND CANCELLOUS BONE
    LANGTON, CM
    ALI, AV
    RIGGS, CM
    EVANS, GP
    BONFIELD, W
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1990, 11 (03): : 243 - 249
  • [8] Comparison of PES membrane chemical cleaning efficiency using different protocols
    Skorvan, O.
    Holba, M.
    Bodik, I.
    Mikulasek, P.
    EUROMEMBRANE CONFERENCE 2012, 2012, 44 : 1860 - 1863
  • [9] Bioactive Ti metal analogous to human cancellous bone: Fabrication by selective laser melting and chemical treatments
    Pattanayak, Deepak K.
    Fukuda, A.
    Matsushita, T.
    Takemoto, M.
    Fujibayashi, S.
    Sasaki, K.
    Nishida, N.
    Nakamura, T.
    Kokubo, T.
    ACTA BIOMATERIALIA, 2011, 7 (03) : 1398 - 1406
  • [10] Ultrasonic Consequence of Different Common Sterilization Treatments Applied to Human Bone Before Transplantation
    Vastel, L.
    Masse, C.
    Crozier, E.
    Mesnil, P.
    Padilla, F.
    Laugier, P.
    Mitton, D.
    Bardonnet, R.
    Courpied, J. P.
    2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS, 2006, : 2104 - +