A charge-coupled device (CCD) camera was used to acquie movies of transmembrane activity from thin slices of sheep ventricular epicardial muscle stained with a voltage-sensitive dye. Compared with photodiodes, CCDs have high spatial resolution, but low temporal resolution. Spatial resolution in our system ranged from 0.04 to 0.14 mm/pixel; the acquisition rate was 60, 120, or 240 frames/sec. Propagating waves were readily visualized after subtraction of a background image. The optical signal had an amplitude of 1 to 6 gray levels, with signal-to-noise ratios between 1.5 and 4.4. Because CCD cameras in-tegrate light over the frame interval, moving objects, including propagating waves, are blurred in the resulting movies. A computer model of such an integrating imaging system was developed to study the effects of blur, noise, filtering, and quantization on the ability to measure conduction velocity and action potential duration (APD). The model indicated that blurring, filtering, and quantization do not affect the ability to localize wave fronts in the optical data (i.e., no systematic error in determining spatial position), but noise does increase the uncertainty of the measurements. The model also showed that the low frame rates of the CCD camera introduced a systematic error in the calculation of APD: for cutoff levels >50%, the APD was erroneusly long. Both noise and quantization increased the uncertainty in the APD measurements. The optical measures of conduction velocity were not significantly different from those measured simultaneously with microelectrodes. Optical APDs, however, were longer than the electrically recorded APDs. This APD error could be reduced by using the 50% cutoff level and the fastest frame rate possible.
引用
收藏
页码:713 / 725
页数:12
相关论文
共 34 条
  • [1] Technical features of a CCD video camera system to record cardiac fluorescence data
    Baxter, WT
    Davidenko, JM
    Loew, LM
    Wuskell, JP
    Jalife, J
    ANNALS OF BIOMEDICAL ENGINEERING, 1997, 25 (04) : 713 - 725
  • [2] CCD video data sampling technique in the ocean water color camera
    Huang, QL
    Zhu, M
    Jin, WQ
    OCEAN REMOTE SENSING AND APPLICATIONS, 2003, 4892 : 194 - 204
  • [3] CCD-STREAK CAMERA DATA ACQUISITION-SYSTEM
    CHENG, J
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1979, 24 (08): : 1099 - 1099
  • [4] Medical Fluorescence Imaging Processing System Based on 2CCD Camera
    Wang, Yanxiang
    Wang, Mingquan
    Wang, Yu
    Yang, Xiaofeng
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON COMPUTER SCIENCE AND ENGINEERING TECHNOLOGY (CSET2015), MEDICAL SCIENCE AND BIOLOGICAL ENGINEERING (MSBE2015), 2016, : 421 - 424
  • [5] Detection of the fluorescence of GI vessels in rats using a CCD camera or a near-infrared video endoscope
    Borotto, E
    Englender, J
    Pourny, JC
    Naveau, S
    Chaput, JC
    Lecarpentier, Y
    GASTROINTESTINAL ENDOSCOPY, 1999, 50 (05) : 684 - 688
  • [6] APPLICABILITY OF A NONCOOLED VIDEO-RATED CCD CAMERA FOR DETECTION OF FLUORESCENCE IN-SITU HYBRIDIZATION SIGNALS
    VROLIJK, J
    SLOOS, WCR
    VERWOERD, NP
    TANKE, HJ
    CYTOMETRY, 1994, 15 (01): : 2 - 11
  • [7] Technical Note: Range verification system using edge detection method for a scintillator and a CCD camera system
    Saotome, Naoya
    Furukawa, Takuji
    Hara, Yousuke
    Mizushima, Kota
    Tansho, Ryohei
    Saraya, Yuichi
    Shirai, Toshiyuki
    Noda, Koji
    MEDICAL PHYSICS, 2016, 43 (04) : 1754 - 1759
  • [8] Analysis of Molecular Concentration and Brightness from Fluorescence Fluctuation Data with an Electron Multiplied CCD Camera
    Unruh, Jay R.
    Gratton, Enrico
    BIOPHYSICAL JOURNAL, 2008, 95 (11) : 5385 - 5398
  • [9] Use of KLV to combine metadata, camera sync, and data acquisition into a single video record
    Hightower, Paul
    MOTION IMAGERY: STANDARDS, QUALITY, AND INTEROPERABILITY, 2015, 9463
  • [10] Design of data collection system for high performance CCD camera based on Web server
    College of Optoelectronic Information, University of Electronic Science and Technology of China, Chengdu 610054, China
    不详
    Bandaoti Guangdian, 2006, 5 (621-623):